弱视双眼掩蔽揭示眼间抑制的方向依赖性与失衡
结果显示弱视眼诱导的抑制弱于对侧眼,对侧眼抑制与对照相似;弱视者在低、中空间频率下平行配置抑制弱于正交配置,高空间频率无此差异。
要点
- 弱视眼诱导的掩蔽抑制弱于对侧眼,对侧眼抑制与对照相似。
- 弱视者低、中空间频率下平行配置抑制弱于正交配置,高空间频率无差异。
- 双眼掩蔽失衡导致双眼 viewing 时弱视眼净抑制,模拟临床抑制。
核心结论
- 弱视异常眼间掩蔽在低、中空间频率显示正常对照预期的方向选择性特征,高空间频率则无。
- 弱视者双眼间双眼掩蔽失衡导致双眼观看时弱视眼净抑制,模拟临床抑制。
研究设计与样本
- 通过测试眼呈现目标Gabor、另一眼呈现平均亮度(单眼)或带通方向滤波噪声(掩蔽)测量对比敏感度,以阈值差定义眼间抑制。
- 在平行与正交抑制配置下测量眼间抑制,目标与掩蔽峰空间频率在实验1为0.25 c/d(低)、实验2为1.31 c/d(中)、实验3为6.87 c/d(高)。
主要发现
- 弱视眼诱导的掩蔽抑制弱于对侧眼诱导的抑制。
- 对侧眼诱导的抑制与对照者观察到的抑制相似。
- 弱视者在低、中空间频率下平行配置的眼间抑制弱于正交配置,高空间频率下无此差异。
临床怎么用
- 弱视眼间抑制的方向依赖性与空间频率相关,评估时需考虑不同空间频率与方向配置。
- 双眼掩蔽失衡可模拟临床抑制,提示双眼观看时弱视眼受净抑制。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We investigate the orientation tuning of interocular suppression using a dichoptic masking paradigm in adult controls and amblyopes. METHODS: Fourteen adults with anisometropic or mixed amblyopia and 10 control adults participated in our study. Contrast sensitivity was measured by presenting a target Gabor in the tested eye and mean luminance in the untested eye (monocular) and by presenting a target in the tested eye and a bandpass oriented filtered noise in the other eye (masked). Interocular suppression was defined as the thresholds difference between the monocular and masked conditions for each eye. Interocular suppression was measured under parallel and orthogonal suppression configurations. The peak spatial frequency of the target and mask was 0.25 c/d in experiment 1 (low), 1.31 c/d in experiment 2 (mid), and 6.87 c/d in experiment 3 (high). RESULTS: The masking suppression induced by the amblyopic eye was less strong than that induced by the fellow eye. The suppression from the fellow eye was similar to that observed in the controls. Interocular suppression under parallel configuration was less strong than under orthogonal configuration in amblyopes at low and mid spatial frequency, but not at high spatial frequency. CONCLUSIONS: We demonstrate that the abnormal interocular masking in amblyopia displays the expected characteristic of orientation selectivity expected of normal controls at low and mid spatial frequency, but not at high spatial frequency. The dichoptic masking imbalance between the eyes of amblyopes results in a net suppression of the amblyopic eye during binocular viewing, modeling clinical suppression.
引用
- Gong L, Reynaud A, Wang Z, et al. Interocular Suppression as Revealed by Dichoptic Masking Is Orientation-Dependent and Imbalanced in Amblyopia. Invest Ophthalmol Vis Sci. 2020. PMID: 33369637. doi:10.1167/iovs.61.14.28
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。