文献速递白内障与屈光手术角膜与眼表疾病

低脉冲能量飞秒激光弧形角膜切开术治疗低中度角膜散光的1年结果

One-Year Results of Arcuate Keratotomy in Patients With Low to Moderate Corneal Astigmatism Using a Low-Pulse-Energy Femtosecond Laser.
PubMed 文献 · Am J Ophthalmol · 2020-12-09

一项前瞻性干预病例系列研究纳入43例年龄相关性白内障且总角膜散光1至3D的患者,采用低能量飞秒激光行配对弧形角膜切开术。术后1年角膜前表面散光和总角膜散光显著降低,后表面散光无显著变化,角膜高阶像差显著改善。

要点

  • 低能量飞秒激光弧形角膜切开术可有效降低低中度角膜散光并维持1年稳定。
  • 术后角膜前表面散光和总角膜散光显著下降,后表面散光无显著改变。
  • 角膜波前高阶像差在术后1个月、3个月和1年均显著改善。

核心结论

  • 低能量飞秒激光创建的配对表面穿透弧形角膜切开术在术后1年内有效且稳定地降低角膜散光。
  • 角膜光学质量得以保留,高阶像差较术前降低。

研究设计与样本

  • 前瞻性干预病例系列研究,设置于维也纳医科大学眼科。
  • 纳入43例年龄相关性白内障患者的43只眼,总角膜散光在1至3D之间。

主要发现

  • 术前平均角膜前表面散光1.62±0.49D和总角膜散光1.58±0.44D,术后1年分别显著降至0.66±0.38D和0.50±0.30D(P<.001)。
  • 后表面散光术前0.31±0.19D,术后1年0.31±0.13D,无显著变化(P=.732)。
  • 矢量散光分析显示的散光在术后1个月、3个月和1年保持稳定。
  • 角膜波前高阶像差在术后1个月、3个月和1年显著改善。

关键数值与推荐

  • 配对弧形角膜切开术使用低能量飞秒激光(LDV Z8;Ziemer Ophthalmic Systems,Port,瑞士)制作,并联合散光中性手动后角膜缘白内障切口。
  • 在术前及术后1个月、3个月和1年进行角膜散光和高阶像差测量。

临床怎么用

  • 对于年龄相关性白内障合并低中度总角膜散光(1至3D)的患者,可考虑采用低能量飞秒激光弧形角膜切开术矫正散光。
  • 术后应关注角膜前表面和总角膜散光的变化,后表面散光可能无显著改变。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate corneal astigmatism (CA) reduction and corneal optical quality after surface-penetrating femtosecond laser arcuate keratotomies (Femto AK) considering anterior (CAant) and posterior corneal curvature (CApost), total corneal refractive power astigmatism (CAtot), and corneal higher-order aberrations (HOAs) through 1 year. DESIGN: Prospective interventional case series. METHODS: Setting: Department of Ophthalmology, Medical University of Vienna. PatientPopulation: Forty-three eyes of 43 patients with age-related cataract and CAtot between 1 and 3 diopters (D). INTERVENTION: Paired keratotomies were created with a low-energy femtosecond laser (LDV Z8; Ziemer Ophthalmic Systems, Port, Switzerland) and combined with an astigmatic neutral manual posterior-limbal cataract incision. CA and HOAs measurements were obtained preoperatively and after 1 month, 3 months, and 1 year. MainOutcomeMeasure: Change of CA and HOAs after low-energy Femto AK through 1 year. RESULTS: Mean preoperative CAant and CAtot (1.62 ± 0.49 D and 1.58 ± 0.44 D) were significantly reduced, to 0.66 ± 0.38 and 0.50 ± 0.30 D (P < .001) 1 year after surgery, respectively. CApost showed no significant change, from 0.31 ± 0.19 D preoperatively to 0.31 ± 0.13 D (P = .732) at the 1-year follow-up period. Astigmatism as calculated by vector astigmatism analysis stayed stable at 1 month, 3 months, and 1 year. Corneal wavefront HOAs significantly improved at 1 month, 3 months, and 1 year. CONCLUSIONS: Paired surface-penetrating keratotomies created by a low-energy femtosecond laser showed efficient and stable CA reduction within 1 year after surgery. The optical quality of the cornea was preserved with lower HOAs than preoperatively.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Schwarzenbacher L, Schartmüller D, Röggla V, et al. One-Year Results of Arcuate Keratotomy in Patients With Low to Moderate Corneal Astigmatism Using a Low-Pulse-Energy Femtosecond Laser. Am J Ophthalmol. 2020. PMID: 33309694. doi:10.1016/j.ajo.2020.11.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。