Ahmed FP7与Baerveldt 250/350患者健康相关生活质量与药物治疗对照比较
该前瞻性队列研究纳入128例青光眼引流装置(GDD)患者(FP7 35例、B250 32例、B350 61例),术后≥30天使用VFQ-25、AS-20和复视问卷评估健康相关生活质量(HRQoL),并与药物治疗对照组比较。结果显示所有GDD组HRQoL子评分均低于对照组,B350患者AS-20自我感知子量表评分较低,但三种GDD之间无显著差异。
要点
- 年轻、复视、视力较低、平均偏差较差或使用GDD与HRQoL降低相关。
- 所有GDD组HRQoL子评分均低于药物治疗对照组。
- B350患者AS-20自我感知评分较低,三种GDD间无显著差异。
核心结论
- 年轻、复视、视力较低、平均偏差较差或使用GDD的青光眼患者HRQoL较低。
- B350患者自我感知评分较低,可能与装置更明显或更易被感知有关。
研究设计与样本
- 前瞻性队列研究,2017年8月至2019年7月纳入128例GDD患者(FP7 35例、B250 32例、B350 61例)及药物治疗对照组。
- GDD患者术后≥30天、对照组入组时完成VFQ-25、AS-20和复视问卷。
主要发现
- 单因素分析中HRQoL降低与年轻年龄(r2范围0.042-0.071)、复视(r2范围0.039-0.119)、GDD治疗(r2范围0.023-0.103)、较低视力(r2范围0.021-0.215)和较差平均偏差(r2范围0.029-0.131)相关。
- 所有GDD组HRQoL子评分均低于对照组。
- 与对照组相比,B350患者AS-20自我感知子量表评分较低,B250和B350患者阅读和一般功能子量表评分较低,FP7和B350患者VFQ-25视觉功能子量表评分较低。
- 三种GDD之间无显著差异。
临床怎么用
- 临床评估青光眼患者HRQoL时需关注年龄、复视、视力、视野平均偏差及GDD使用情况。
- 选择B350时需注意患者自我感知评分可能较低,应加强相关咨询。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare health-related quality of life (HRQoL) in patients with Ahmed FP7 (FP7), Baerveldt 250 (B250) and Baerveldt 350 (B350) glaucoma drainage device (GDDs), and medically treated controls. METHODS: This was a prospective cohort study from August 2017 to July 2019. The NEI 25-Item Visual Function Questionnaire (VFQ-25), the Adult Strabismus-20 questionnaire (AS-20) and the Diplopia Questionnaire were conducted ≥30 days postoperatively in GDD patients, on enrolment for controls. Age, sex, treatment type, visual acuity, mean deviation and diplopia were evaluated for association with HRQoL RESULTS: Of the 128 GDD patients enrolled, 35 (27.3%) had FP7, 32 (25.0%) had B250 and 61 (47.7%) had B350. In univariate analysis, decreased HRQoL was associated with younger age (r2 range 0.042-0.071), diplopia (r2 range 0.039-0.119), GDD treatment (r2 range 0.023-0.103), lower visual acuity (r2 range 0.021-0.215) and worse mean deviation (r2 range 0.029-0.131). All GDD groups had lower HRQoL subscores than the controls. HRQoL scores were lower compared with controls among B350 patients for AS-20 Self-perception subscale, B250 and B350 for Reading and General Function subscales, and FP7 and B350 for VFQ-25 Visual Functioning subscale. There were no significant differences among the GDDs. CONCLUSIONS: Glaucoma patients with a younger age, diplopia, lower visual acuity, worse mean deviation or a GDD had lower HRQoL. Those with B350 had lower self-perception scores, consistent with previous reports in the literature. This subscale was not diminished in FP7 or B250, so the decreased self-perception scores may be due to greater visibility or awareness of the B350.
引用
- Kilgore KP, Wang F, Stern NC, et al. Health-related quality of life in Ahmed FP7, and Baerveldt 250 and 350 patients compared with medical controls. Br J Ophthalmol. 2020. PMID: 33328185. doi:10.1136/bjophthalmol-2020-317856
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。