原发性开角型青光眼局灶结构-功能关系:OCT与OCT-A测量
本研究纳入86例原发性开角型青光眼患者的119只眼,采用标准自动视野计、OCT神经纤维层厚度和OCT-A血管测量,通过解剖调整的神经纤维轨迹映射局灶视野位点与OCT/OCT-A测量,并用多变量混合效应和分段回归分析。结果显示局灶毛细血管密度与更广泛视野缺损显著相关,且中央10°内低于断点时视野缺损与局灶毛细血管密度显著相关而与神经纤维层厚度无关。
要点
- 局灶毛细血管密度与34个视野位点(66.7%的24-2视野)显著相关,其中24个位于20°偏心度内。
- 局灶神经纤维层厚度仅与16个视野位点(31.4%的24-2视野)显著相关,其中8个位于20°偏心度内。
- 中央10°视野内低于断点的视野缺损与局灶毛细血管密度显著相关(斜率0.89±0.12,P<0.001),与神经纤维层厚度无关(斜率0.57±0.39,P=0.15)。
核心结论
- 局灶毛细血管密度较神经纤维层厚度与更广泛视野缺损和更大比例视野区域显著相关。
研究设计与样本
- 横断面研究,纳入86例中国原发性开角型青光眼患者的119只眼,进行标准自动视野计、OCT神经纤维层厚度和OCT-A成像。
主要发现
- 视野平均偏差与全局毛细血管灌注密度(β=0.13±0.08)和全局视网膜神经纤维层厚度(β=0.09±0.02)显著相关。
- 局灶毛细血管密度与34个视野测试位点(66.7%的24-2视野)的视野缺损显著相关,其中24个位点位于20°偏心度内。
- 局灶神经纤维层厚度与16个视野测试位点(31.4%的24-2视野)的视野缺损显著相关,其中8个位点位于20°偏心度内。
- 中央10°视野内低于断点的视野缺损与局灶毛细血管密度显著相关(斜率0.89±0.12,P<0.001),与局灶神经纤维层厚度无显著相关(斜率0.57±0.39,P=0.15)。
临床怎么用
- 在原发性开角型青光眼评估中,OCT-A局灶毛细血管密度可能较OCT神经纤维层厚度检测更广泛的视野缺损区域。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the focal structure-function associations among visual field (VF) loss, optical coherence tomography angiography (OCT-A) vascular measurements, and optical coherence tomography (OCT) structural measurements in glaucoma. METHODS: In this cross-sectional study, subjects underwent standard automated perimetry, OCT-based nerve fiber thickness measurements, and OCT-A imaging. Mappings of focal VF test locations with OCT and OCT-A measurements were defined using anatomically adjusted nerve fiber trajectories and were studied using multivariate mixed-effects analysis. Segmented regression analysis was used to determine the presence of breakpoints in the structure-function associations. RESULTS: The study included 119 eyes from 86 Chinese subjects with primary open-angle glaucoma (POAG). VF mean deviation was significantly associated with global capillary perfusion density (β = 0.13 ± 0.08) and global retinal nerve fiber layer thickness (β = 0.09 ± 0.02). Focal capillary density (FCD) was significantly associated with VF losses at 34 VF test locations (66.7% of 24-2 VF), with 24 of the 34 locations being within 20° of retinal eccentricity. Focal nerve layer (FNL) thickness was significantly associated with 16 VF test locations (31.4% of 24-2 VF; eight locations within 20° eccentricity). For VF test locations in the central 10° VF, VF losses below the breakpoint were significantly associated with FCD (slope, 0.89 ± 0.12, P < 0.001), but not with FNL thickness (slope, 0.57 ± 0.39, P = 0.15). CONCLUSIONS: Focal capillary densities were significantly associated with a wider range of visual field losses and in a larger proportion of the visual field compared to nerve fiber thickness.
引用
- Wong D, Chua J, Lin E, et al. Focal Structure-Function Relationships in Primary Open-Angle Glaucoma Using OCT and OCT-A Measurements. Invest Ophthalmol Vis Sci. 2020. PMID: 33372979. doi:10.1167/iovs.61.14.33
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。