文献速递眼底病与葡萄膜炎

双光子激发测量光感受器红外光敏感度作为糖尿病视网膜病变指标

THE LOSS OF INFRARED LIGHT SENSITIVITY OF PHOTORECEPTOR CELLS MEASURED WITH TWO-PHOTON EXCITATION AS AN INDICATOR OF DIABETIC RETINOPATHY: A Pilot Study.
PubMed 文献 · Retina · 2021-01-01

该初步研究纳入28例健康者和34例糖尿病视网膜病变患者,用双光子激发设备测量暗适应后中央凹和旁中央凹的红外光阈值。糖尿病患者平均Snellen视力6/7.7差于健康者6/5.5(P<0.001),对比敏感度降低,红外光敏感度11.6±2.0 dB显著低于正常眼15.5±1.3 dB(P<0.001)。

要点

  • 糖尿病视网膜病变患者红外光敏感度显著低于健康对照。
  • 双光子激发可用于视网膜功能评估。
  • 需进一步研究验证不同分期糖尿病视网膜病变的红外光刺激。

核心结论

  • 与健康对照相比,糖尿病患者的红外光敏感度显著受损。
  • 双光子测量可用于视网膜疾病评估,但需进一步研究验证不同分期糖尿病视网膜病变的红外光刺激。

研究设计与样本

  • 所有参与者接受全面眼科检查,评估视力和对比敏感度。
  • 暗适应30分钟后,使用双光子激发设备(整合脉冲激光1,045 nm)测量中央凹和旁中央凹的红外阈值,并用扫描激光检眼镜进行眼底成像。

主要发现

  • 糖尿病患者平均Snellen视力为6/7.7,差于健康者的6/5.5,差异有统计学意义(P < 0.001)。
  • 糖尿病患者对比敏感度降低,尤其在6和18 cycles/degree时。
  • 糖尿病视网膜病变眼对红外光的平均视网膜敏感度为11.6 ± 2.0 dB,显著低于正常眼的15.5 ± 1.3 dB(P < 0.001)。

关键数值与推荐

  • 糖尿病视网膜病变眼红外光敏感度11.6 ± 2.0 dB,正常眼15.5 ± 1.3 dB,组间P < 0.001。
  • 糖尿病患者平均Snellen视力6/7.7,健康者6/5.5,组间P < 0.001。
  • 对比敏感度在6和18 cycles/degree处降低。

临床怎么用

  • 双光子激发测量红外光敏感度可作为评估视网膜功能的潜在指标。
  • 用于糖尿病视网膜病变评估时,需结合视力和对比敏感度等检查综合判断。

局限性

  • 需进一步研究验证红外光刺激在不同分期糖尿病视网膜病变中的应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Human photoreceptors are sensitive to infrared light (IR). This sensitivity can be used as a novel indicator of retinal function. Diabetic retinopathy patients were assessed using in vivo two-photon excitation and compared their scotopic IR threshold with that of healthy patients. METHODS: Sixty-two participants, 28 healthy and 34 with diabetic retinopathy, underwent a comprehensive eye examination, where visual acuity and contrast sensitivity were assessed. Infrared thresholds were measured in the fovea and parafovea following 30-minute dark adaptation. A two-photon excitation device was used with integrated pulsed laser light (1,045 nm) for sensitivity testing and scanning laser ophthalmoscopy for fundus imaging. RESULTS: The mean Snellen visual acuity of diabetic patients (6/7.7) was worse than that of the healthy patients (6/5.5), which was significantly different (P < 0.001). Disease patients had decreased contrast sensitivity, especially at 6 and 18 cycles/degree. The mean retinal sensitivity to IR light in eyes with diabetic retinopathy (11.6 ± 2.0 dB) was significantly (P < 0.001) lower than that in normal eyes (15.5 ± 1.3 dB). CONCLUSION: Compared with healthy control subjects, the IR light sensitivity of diabetic patients was significantly impaired. Two-photon measurements can be used in the assessment of retinal disease, but further studies are needed to validate IR light stimulation in various stages of diabetic retinopathy.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Łabuz G, Rayamajhi A, Khoramnia R, et al. THE LOSS OF INFRARED LIGHT SENSITIVITY OF PHOTORECEPTOR CELLS MEASURED WITH TWO-PHOTON EXCITATION AS AN INDICATOR OF DIABETIC RETINOPATHY: A Pilot Study. Retina. 2021. PMID: 33323904. doi:10.1097/IAE.0000000000003032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。