硅油与全氟丙烷气体填充在增生性糖尿病视网膜病变玻璃体切除术中的随机临床试验
PURPOSE: To compare vitreous substitution with silicone oil to perfluoropropane gas in proliferative diabetic retinopathy subjects undergoing pars plana vitrectomy (PPV) for the treatment of tractional retinal detachment or extensive fibrous proliferation.…
要点
- 气体填充组6个月最佳矫正视力优于硅油组。
- 气体组更多患者达到20/50或更好及20/200或更好视力。
- 两组术中术后并发症及非计划玻璃体切除术无显著差异。
核心结论
- 在因牵拉性视网膜脱离或广泛纤维增生行玻璃体切除术的增生性糖尿病视网膜病变患者中,硅油-全氟丙烷气体填充较硅油填充在6个月时获得更好的视力。
主要发现
- 气体组6个月最佳矫正视力优于硅油组(P < 0.001)。
- 气体组更多患者达到0.4 logMAR(20/50)或更好视力(P = 0.02)。
- 气体组更多患者达到1 logMAR(20/200)或更好视力(P < 0.001)。
- 两组基线特征、术中或术后并发症及非计划玻璃体切除术发生率无显著差异。
关键数值与推荐
- 主要结局为6个月随访时最佳矫正视力。
- 硅油组使用1,000厘沲硅油填充,气体组使用14%至16%硅油-全氟丙烷气体填充。
临床怎么用
- 在此类患者群体中,术者可考虑将硅油-全氟丙烷气体填充作为首选的玻璃体替代物。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare vitreous substitution with silicone oil to perfluoropropane gas in proliferative diabetic retinopathy subjects undergoing pars plana vitrectomy (PPV) for the treatment of tractional retinal detachment or extensive fibrous proliferation. DESIGN: Randomized clinical trial. METHODS: Three hundred and two proliferative diabetic retinopathy subjects with tractional retinal detachment or extensive fibrous proliferation requiring PPV were enrolled into the trial. Subjects were prospectively randomized into one of two vitreous substitution groups during PPV: Group A subjects underwent 1,000 centistoke silicone oil tamponade, whereas Group B subjects underwent 14% to 16% silicone oil to perfluoropropane gas tamponade. The principal outcome was the best-corrected visual acuity at 6-month follow-up. Secondary outcomes were postoperative complications and unplanned PPV during the 6-month trial interval. RESULTS: Two hundred and fifty-eight subjects were randomized to receive a vitreous substitute and completed 6-month follow-up. Group B had better best-corrected visual acuity, more subjects ending up with 0.4 logarithm of the minimum angle of resolution (20/50) or better visual acuity, and more subjects ending up with 1 logarithm of the minimum angle of resolution (20/200) or better visual acuity at 6 months compared with Group A (P < 0.001, P = 0.02, P < 0.001, respectively). There were no significant differences in baseline characteristics, intraoperative or postoperative complications, or incidence of unplanned PPV between groups. CONCLUSION: This trial demonstrated that vitreous substitution with silicone oil to perfluoropropane gas resulted in better visual acuity at 6 months compared with silicone oil tamponade in proliferative diabetic retinopathy patients undergoing PPV for tractional retinal detachment or extensive fibrous proliferation. Surgeons should consider silicone oil to perfluoropropane gas tamponade as the first-line vitreous substitute in this patient population.
引用
- Rush RB, Del Valle Penella A, Reinauer RM, et al. SILICONE OIL VERSUS PERFLUOROPROPANE GAS TAMPONADE DURING VITRECTOMY FOR TRACTIONAL RETINAL DETACHMENT OR FIBROUS PROLIFERATION: A Randomized Clinical Trial. Retina. 2021. PMID: 33252584. doi:10.1097/IAE.0000000000003052
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。