含两性霉素B的新型保存液与Optisol-GS保存人供体角膜的比较
本研究比较了含2.5 μg/ml两性霉素B的Kerasave与Optisol-GS在2-8°C下保存人供体角膜14天的效果。结果显示两组在所有时间点的定性和定量指标均无差异,Kerasave与Optisol-GS的保存效果相当。
要点
- Kerasave与Optisol-GS保存14天后角膜内皮细胞密度和中央角膜厚度无显著差异。
- 两组角膜透明度和内皮细胞形态在所有评估时间点均无差异。
- 含两性霉素B的Kerasave可作为Optisol-GS的潜在替代保存液。
核心结论
- 含两性霉素B的Kerasave保存液在2-8°C下保存人供体角膜14天,其保存效果与Optisol-GS相当。
研究设计与样本
- 在保存第1天、第7天和第14天评估中央角膜厚度、内皮细胞密度、内皮细胞死亡率和形态及角膜透明度。
主要发现
- 在所有测试时间点,Kerasave组与Optisol-GS组的角膜透明度、内皮细胞形态、内皮细胞密度、中央角膜厚度和内皮细胞死亡率均无差异。
- 第14天时,Kerasave组和Optisol-GS组的内皮细胞密度分别为2312±98和2335±128 cells/mm2(p=0.886)。
- 第14天时,Kerasave组和Optisol-GS组的中央角膜厚度分别为717±17和697±19 μm(p=0.454)。
- 第14天时,Kerasave组和Optisol-GS组的中央内皮细胞死亡率分别为0.54%±0.40%和0.14%±0.14%(p=0.719)。
临床怎么用
- Kerasave可用于人供体角膜的冷藏保存,保存效果与Optisol-GS相当。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIM: We compared the quality of human donor corneas stored in a cold storage medium containing 2.5 μg/ml of amphotericin B (Kerasave, AL.CHI.MI.A. S.R.L., Ponte San Nicolò, Italy) and Optisol-GS (Bausch & Lomb Inc., Bridgewater, NJ, USA) for 14 days. METHODS: Sixteen pairs of human donor corneas were collected in Eusol-C (AL.CHI.MI.A. S.R.L., Ponte San Nicolò, Italy). Next, all tissues underwent the first evaluation that included the assessments of central corneal thickness (CCT), endothelial cell density (ECD) measured using both trypan blue staining and specular microscopy, endothelial cell (EC) mortality and morphology, and corneal transparency within 24 hours from recovery (Day 1). Afterwards, one cornea of each pair was transferred into Kerasave or Optisol-GS. ECD and CCT were also assessed at Day 7, and all the metrics were evaluated again at the end of the storage period (Day 14). RESULTS: At all tested time points, no differences were found in the qualitative (corneal transparency, EC morphology) and quantitative metrics (ECD, CCT, EC mortality) between the Kerasave and the Optisol-GS storage groups. At Day 14, the corneas stored in Kerasave and Optisol-GS showed ECD of 2312±98 and 2335±128 cells/mm2 (p=0.886), CCT of 717±17 and 697±19 μm (p=0.454) and central EC mortality of 0.54%±0.40% and 0.14%±0.14% (p=0.719), respectively. CONCLUSIONS: The new amphotericin B-containing medium Kerasave was comparable to Optisol-GS in terms of preservation of corneal characteristics at 2-8°C for 14 days.
引用
- Mistò R, Giurgola L, Pateri F, et al. A new storage medium containing amphotericin B versus Optisol-GS for preservation of human donor corneas. Br J Ophthalmol. 2020. PMID: 33172862. doi:10.1136/bjophthalmol-2020-317136
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。