前眼动态光学相干弹性成像:理解角膜缘生物力学
本研究利用波基光学相干弹性成像(OCE)在离体猪眼上评估不同眼内压(IOP)下角膜、巩膜和角膜缘的弹性变化。结果显示,在生理性IOP(15 mm Hg)下角膜缘波速(6.5 m/s)介于角膜(2.9 m/s)和巩膜(10.0 m/s)之间;随着IOP升高,角膜缘波速快速增加甚至超过巩膜,且相同IOP变化下角膜缘波速变化(ΔcL∼18.5 m/s)大于角膜(Δcc∼12.6 m/s)和巩膜(Δcs∼8.1 m/s)。这表明角膜缘在眼 globe 因IOP升高而变形时具有高度非线性。
要点
- 波基OCE可评估角膜缘生物力学特性。
- 生理性IOP下角膜缘波速介于角膜和巩膜之间。
- 角膜缘对IOP变化的弹性响应比角膜和巩膜更显著。
核心结论
- 波基OCE可用于评估角膜缘生物力学特性。
- 角膜缘在IOP升高导致眼球变形时相比角膜和巩膜表现出高度非线性。
- 角膜缘可能具有足够的结构柔韧性以在IOP变化期间稳定前眼形状。
研究设计与样本
- 研究使用离体猪眼(n=8),在角膜巩膜缘附近巩膜机械诱导800 Hz连续谐波弹性波。
- 采用相位敏感光学相干断层扫描(PhS-OCT)成像波传播,在五个IOP水平(10、15、20、30和40 mm Hg)下计算角膜、角膜缘和巩膜区域的波速。
- 对相同区域在相同激励条件下进行有限元分析(FEA)以验证结果。
主要发现
- FEA表明异质角膜-角膜缘-巩膜过渡的刚度可通过800 Hz弹性波的相速度测量表征。
- 在生理性IOP(15 mm Hg)下,角膜缘波速(cL=6.5 m/s)介于角膜(cc=2.9 m/s)和巩膜(cs=10.0 m/s)之间。
- 随着IOP升高,角膜缘波速快速增加,甚至超过巩膜波速。
- 相同IOP变化下,角膜缘波速变化(ΔcL∼18.5 m/s)大于角膜(Δcc∼12.6 m/s)和巩膜(Δcs∼8.1 m/s)。
关键数值与推荐
- 在生理性IOP(15 mm Hg)下,角膜缘波速为6.5 m/s,角膜为2.9 m/s,巩膜为10.0 m/s。
- 相同IOP变化下,角膜缘波速变化为∼18.5 m/s,角膜为∼12.6 m/s,巩膜为∼8.1 m/s。
临床怎么用
- 波基OCE可用于评估角膜缘生物力学特性,辅助理解前眼对IOP变化的响应。
- 角膜缘的高非线性提示其在IOP波动时可能对维持前眼形状有重要作用。
局限性
- 研究使用离体猪眼,结果可能不完全适用于在体人眼。
- 样本量较小(n=8),需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Currently, the biomechanical properties of the corneo-scleral limbus when the eye-globe deforms are largely unknown. The purpose of this study is to evaluate changes in elasticity of the cornea, sclera, and limbus when subjected to different intraocular pressures (IOP) using wave-based optical coherence elastography (OCE). Special attention was given to the elasticity changes of the limbal region with respect to the elasticity variations in the neighboring corneal and scleral regions. METHODS: Continuous harmonic elastic waves (800 Hz) were mechanically induced in the sclera near the corneo-sclera limbus of in situ porcine eye-globes (n = 8). Wave propagation was imaged using a phase-sensitive optical coherence tomography system (PhS-OCT). The eyes were subjected to five different IOP-levels (10, 15, 20, 30, and 40 mm Hg), and spatially distributed propagation velocities were calculated along corneal, limbal, and scleral regions. Finite element analysis (FEA) of the same regions under the same excitation conditions were conducted for further validation of results. RESULTS: FEA demonstrated that the stiffness of the heterogeneous cornea-limbus-sclera transition can be characterized by phase velocity measurements of the elastic waves produced at 800 Hz in the anterior eye. Experimental results revealed that the wave speed in the limbus (cL = 6.5 m/s) is between the cornea (cc = 2.9 m/s) and sclera (cs = 10.0 m/s) at a physiological IOP level (15 mm Hg) and rapidly increases as the IOP level is increased, even surpassing the wave speed in the sclera. Finally, the change in elastic wave speed in the limbus (ΔcL∼18.5 m/s) was greater than in the cornea (Δcc ∼12.6 m/s) and sclera (Δcs∼8.1 m/s) for the same change in IOP. CONCLUSIONS: We demonstrated that wave-based OCE can be utilized to assess limbus biomechanical properties. Moreover, experimental evidence showed that the corneo-scleral limbus is highly nonlinear compared to the cornea and sclera when the eye-globe is deformed by an increase of IOP. This may suggest that the limbus has enough structural flexibility to stabilize anterior eye shape during IOP changes.
引用
- Zvietcovich F, Nair A, Singh M, et al. Dynamic Optical Coherence Elastography of the Anterior Eye: Understanding the Biomechanics of the Limbus. Invest Ophthalmol Vis Sci. 2020. PMID: 33141893. doi:10.1167/iovs.61.13.7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。