圆锥角膜配戴角膜硬性透气接触镜期间角膜断层扫描变化
研究纳入32眼圆锥角膜患者,比较配戴与不配戴球面角膜硬性透气接触镜时的角膜断层数据,发现戴镜后后表面球面、规则散光及不对称成分显著减小(均p<0.001),且所有生物力学指标与球面成分差值显著相关。
要点
- 圆锥角膜患者戴角膜GP镜后后表面球面、规则散光及不对称成分显著减小。
- 所有角膜生物力学指标与戴镜前后球面成分差值显著相关。
- 生物力学较弱的角膜中,戴镜导致的后表面变平效应更明显。
核心结论
- 圆锥角膜的角膜生物力学特性与配戴角膜GP镜引起的后表面球面成分变平相关,且该效应在生物力学较弱的角膜中更大。
研究设计与样本
- 纳入每日配戴角膜GP镜且无并发症的圆锥角膜患者为单组,使用三维前段光学相干断层扫描获取同一眼戴镜与不戴镜时的角膜断层数据。
主要发现
- 戴角膜GP镜时后表面中央3mm区的球面、规则散光及不对称成分均显著小于不戴镜时(均p<0.001)。
- 所有生物力学指标均与戴镜前后球面成分差值显著相关。
关键数值与推荐
- 后表面中央3mm区屈光数据经傅里叶谐波分析分解为球面、规则散光、不对称及高阶不规则成分。
- 角膜生物力学指标包括2mm内变形幅度比、综合半径、首次压平刚度参数及线性Corvis生物力学指数。
临床怎么用
- 解读圆锥角膜患者角膜断层数据时需考虑角膜GP镜对后表面球面成分的影响。
- 生物力学较弱的角膜可能对GP镜引起的后表面变平效应更敏感。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIMS: We aimed to investigate the refractive changes in the posterior corneal surface in keratoconus (KC) associated with wearing spherical corneal rigid gas-permeable contact lenses (corneal GPs) with apical touch or three-point touch fitting and the effect of spherical corneal GPs on corneal biomechanics. METHODS: Patients with KC wearing corneal GPs every day without facing complications were enrolled as a single group. Corneal tomographic data were obtained using a three-dimensional anterior segment optical coherence tomography from the same eye with and without corneal GPs. Dioptric data from the central 3-mm zone of the posterior corneal surface were decomposed into spherical, regular astigmatism, asymmetry and higher-order irregularity components using Fourier harmonic analysis. The corneal biomechanical indices were deformation amplitude ratio within 2 mm, integrated radius, stiffness parameter at first applanation and linear Corvis Biomechanical Index. Correlations between the difference in Fourier indices with and without corneal GPs and the corneal biomechanical parameters were analysed. RESULTS: Thirty-two eyes of 32 patients with KC were enrolled. Spherical, regular astigmatism and asymmetry components were significantly smaller with corneal GP wear than without the wear (all p<0.001). All biomechanical indices were significantly correlated with the difference in the spherical components with and without corneal GPs. CONCLUSION: Corneal biomechanical properties of KC were correlated with posterior corneal surface flattening induced by wearing corneal GPs on the spherical components. This effect is greater in biomechanically weaker corneas.
引用
- Koh S, Inoue R, Maeda N, et al. Corneal tomographic changes during corneal rigid gas-permeable contact lens wear in keratoconic eyes. Br J Ophthalmol. 2020. PMID: 33172864. doi:10.1136/bjophthalmol-2020-317057
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。