文献速递白内障与屈光手术

前房深度与晶状体厚度对九种人工晶状体计算公式准确性的影响

Anterior chamber depth, lens thickness and intraocular lens calculation formula accuracy: nine formulas comparison.
PubMed 文献 · Br J Ophthalmol · 2020-11-23

该回顾性病例系列纳入695只眼,按术前前房深度(ACD)分三组、再按晶状体厚度(LT)分三组,比较九种人工晶状体(IOL)计算公式的屈光预测误差。结果显示新一代公式(尤其Kane、PEARL-DGS、EVO V.2.0)在极端ACD-LT组合下更稳定,而Haigis和Hill-RBF V.2.0受LT显著影响。

要点

  • 在ACD≤3.0 mm和≥3.5 mm时,SRK/T、Hoffer Q和Holladay 1的平均预测误差显著偏离0。
  • ACD≤3.0 mm时,PEARL-DGS、Kane、EVO V.2.0和Barrett Universal II比Hoffer Q更准确。
  • Haigis和Hill-RBF V.2.0受LT显著影响:薄晶状体近视漂移,厚晶状体远视漂移。

核心结论

  • 新一代公式,特别是Kane、PEARL-DGS和EVO V.2.0,在极端ACD-LT组合眼中似乎更可靠和稳定。

研究设计与样本

  • 回顾性病例系列,纳入695只眼(695例患者),均为无并发症白内障手术并植入同一型号单焦点IOL。
  • 按术前ACD分三组,每组再按LT分三个亚组,使用优化常数计算九种公式的屈光预测误差。

主要发现

  • ACD≤3.0 mm和≥3.5 mm时,SRK/T、Hoffer Q和Holladay 1的平均预测误差显著不同于0(p<0.05)。
  • ACD≤3.0 mm时,PEARL-DGS、Kane、EVO V.2.0和Barrett Universal II比Hoffer Q更准确(p<0.05)。
  • Kane、PEARL-DGS、EVO V.2.0和Barrett Universal II在各ACD和LT亚组中平均误差和MedAE的方差最低。
  • Haigis和Hill-RBF V.2.0受LT显著影响,独立于ACD:薄晶状体近视漂移,厚晶状体远视漂移(p<0.05)。

关键数值与推荐

  • ACD分组界值:≤3.0 mm、≥3.5 mm;LT亚组划分依据原文未具体报告。
  • 准确性评价指标包括平均预测误差、平均绝对误差、中位绝对误差(MedAE)及±0.25D、±0.50D、±1.00D内眼百分比。

临床怎么用

  • 对于ACD≤3.0 mm或≥3.5 mm的眼,优先考虑Kane、PEARL-DGS、EVO V.2.0或Barrett Universal II而非Hoffer Q等老公式。
  • 使用Haigis或Hill-RBF V.2.0时需注意LT影响:薄晶状体可能近视漂移,厚晶状体可能远视漂移。

局限性

  • 回顾性设计,仅纳入正常眼轴长度患者,未报告LT亚组具体界值及±0.25D等百分比数值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To investigate the influence of anterior chamber depth (ACD) and lens thickness (LT) on 9 intraocular lens (IOL) power calculation formulas accuracy, in patients with normal axial lengths. METHODS: Retrospective case series, including patients having uncomplicated cataract surgery with insertion of a single IOL model, divided into three groups according to preoperative ACD. Each group was further subdivided into three subgroups, according to the LT. Using optimised constants, refraction prediction error was calculated for Barrett Universal II, Emmetropia Verifying Optical (EVO) V.2.0, Haigis, Hill-RBF V.2.0, Hoffer Q, Holladay 1, Kane, PEARL-DGS and SRK/T formulas. Mean prediction error, mean and median absolute error (MedAE) and the percentage of eyes within ±0.25D, ±0.50D and ±1.00D were also calculated. RESULTS: The study included 695 eyes from 695 patients. For ACD ≤3.0 mm and ≥3.5 mm, mean prediction error of SRK/T, Hoffer Q and Holladay 1 was significantly different from 0 (p<0.05). PEARL-DGS, Kane, EVO V.2.0 and Barrett Universal II were more accurate than the Hoffer Q in ACD ≤3.0 mm (p<0.05). Kane, PEARL-DGS, EVO V.2.0 and Barrett Universal II revealed the lowest variance of mean and MedAE by ACD and LT subgroup. Haigis and Hill-RBF V.2.0 were significantly influenced by LT, independently of the ACD, with a myopic shift with thin lenses and a hyperopic shift with thick lenses (p<0.05). CONCLUSION: New generation formulas, particularly Kane, PEARL-DGS and EVO V.2.0, seem to be more reliable and stable even in eyes with extreme ACD-LT combinations.