文献速递青光眼

青光眼患者每周居家视野监测的接受度、持续性与表现

Uptake, Persistence, and Performance of Weekly Home Monitoring of Visual Field in a Large Cohort of Patients With Glaucoma.
PubMed 文献 · Am J Ophthalmol · 2020-11-19

这项单中心观察性纵向依从性研究纳入101名青光眼疑似或稳定期患者的186只眼,使用借用iPad每周居家完成6次视野检查。88%的参与者成功完成至少1次居家检查,69%完成全部6次,居家与临床平均缺损高度相关(R=0.85),但居家视野固视丢失更多。

要点

  • 88%参与者完成至少1次居家视野检查,69%完成全部6次,中位检查间隔7.0天。
  • 居家与临床平均缺损高度相关(R=0.85),居家固视丢失更多但假阳性率相似。
  • IT物流原因、缺乏动力或生活事务冲突是影响接受度和依从性的障碍。

核心结论

  • 居家视野监测可达到较高的短期依从性,结果与临床检查相当。
  • IT物流原因和缺乏动力是影响接受度和依从性的障碍。

研究设计与样本

  • 单中心、观察性、纵向依从性研究,纳入101名青光眼疑似或至少一眼稳定青光眼患者共186只眼。
  • 参与者在常规门诊复查时入组,基线临床视野用Humphrey视野分析仪(HFA,SITA标准)记录,6个月时重复。
  • 参与者被要求使用借用的iPad每周居家完成6次视野检查,接受度定义为从居家返回至少1次检查。
  • 数据以均值±[标准差]或中位数[四分位1-3范围]表示,组间比较采用bootstrap法。

主要发现

  • 88%的参与者成功完成至少1次居家检查,69%完成全部6次检查。
  • 检查间隔中位数为7.0[7.0-8.0]天。
  • 居家视野监测的固视丢失高于HFA,但假阳性(FP)水平与HFA相似。
  • 临床与居家平均缺损高度相关(R=0.85)。
  • 影响接受度和依从性的障碍包括IT物流原因、缺乏动力或生活事务冲突。

临床怎么用

  • 居家视野监测可作为青光眼患者短期视野随访的可行补充手段,短期依从性较高且结果与临床检查相关性好。
  • 实施时需关注IT物流支持和患者动力等障碍,以提高接受度和依从性。

局限性

  • 研究为单中心设计,仅评估短期(6个月内)依从性和表现。
  • 居家视野监测的固视丢失高于临床HFA检查。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study examines the short-term uptake, compliance, and performance of a tablet device used for home monitoring of visual field (VF-Home) by glaucoma patients. DESIGN: Single-center, observational, longitudinal, compliance study. METHODS: Participants who were glaucoma suspects or had stable glaucoma in at least one eye were recruited during a regular clinic review. Baseline in-clinic visual field (VF) was recorded with the Humphrey Field Analyser (HFA, SITA standard) and repeated at 6 months. Participants were tasked with performing 6 VF examinations from home, at weekly intervals, using a loaned iPad tablet. Uptake was defined as returning at least 1 test from home. Reliability and global indices from VF-Home were compared to in-clinic outcomes. Data are shown as either mean ± [standard deviation] or median [quartile 1-3 range], and group comparisons were achieved with bootstrap. RESULTS: We recruited 186 eyes of 101 participants. VF-Home uptake was excellent, with 88% of participants successfully completing ≥1 home examination and 69% completing all 6 examinations. The median duration between tests was 7.0 [7.0-8.0] days. Barriers to uptake and compliance involved information technology (IT) logistical reasons, lack of motivation, or competing life demands. VF-Home gave greater fixation loss but a similar level of False Positives (FP) as the HFA. A high correlation was found for the mean defect between in-clinic and at-home outcomes (R = 0.85). CONCLUSIONS: VF-Home can return a high level of short-term compliance and results comparable to those found by in-clinic testing. IT logistical reasons and lack of motivation are barriers to uptake and compliance.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Prea SM, Kong GYX, Guymer RH, et al. Uptake, Persistence, and Performance of Weekly Home Monitoring of Visual Field in a Large Cohort of Patients With Glaucoma. Am J Ophthalmol. 2020. PMID: 33221287. doi:10.1016/j.ajo.2020.10.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。