文献速递青光眼神经眼科

青光眼患者如何看待自身视野缺损:一款新型iPad应用提升患者对视野丧失的认知

What do patients with glaucoma see: a novel iPad app to improve glaucoma patient awareness of visual field loss.
PubMed 文献 · Br J Ophthalmol · 2020-11-20

本研究开发了一款iPad应用,让12例青光眼患者自我描述视野缺损区域的感知,并与Humphrey视野计阈值对比。结果显示患者将视野缺损描述为模糊而非变暗或变黑,且iPad响应与视网膜敏感度阈值显著相关,模糊对应的截断值约为23 dB。

要点

  • 青光眼患者自我描述视野缺损为模糊,而非变暗或变黑
  • iPad应用可定量表征视野缺损区域的视觉感知
  • iPad响应与Humphrey视野计阈值显著相关,模糊截断值约23 dB

核心结论

  • 青光眼患者将视野缺损自我描绘为模糊,从未描述为变暗或变黑。
  • 该iPad创新应用可将Humphrey视野数据转化为对青光眼视野缺损患者视觉感知的定量表征。

研究设计与样本

  • 研究纳入12例双眼视力≥20/40且2年内Humphrey视野稳定可靠的青光眼患者。
  • 患者使用iPad应用(距离33 cm)调整模糊或变暗程度,以匹配其对1 m处2×2 m墙面海报的感知,海报中心跨越45°视野。
  • 应用输出在Humphrey 24-2测试的54个视网膜位点上的模糊/变暗程度(正常、轻度、重度),并与这些位点的阈值敏感度比较。
  • 分别分析右眼、左眼和整合的双眼视野指数数据。

主要发现

  • 共分析12例受试者(平均年龄71±8.2岁)的36份Humphrey视野和iPad响应。
  • 平均视野指数为右眼77%、左眼76%、双眼83%。
  • 最常见的iPad响应为正常,其次为模糊,无受试者报告变暗响应。
  • 平均Humphrey敏感度阈值与对应视网膜位点的iPad响应显著相关:右眼、左眼、双眼正常分别为23、25、27 dB;轻度模糊为18、16、22 dB;重度模糊为9、9、11 dB。
  • ROC曲线分析显示,受试者报告模糊的Humphrey视网膜敏感度截断值为右眼23.4 dB、左眼23 dB、双眼23.3 dB。

关键数值与推荐

  • 受试者报告模糊的Humphrey视网膜敏感度截断值:右眼23.4 dB,左眼23 dB,双眼23.3 dB。
  • 平均Humphrey敏感度阈值(dB)对应iPad响应:正常右眼23、左眼25、双眼27;轻度模糊右眼18、左眼16、双眼22;重度模糊右眼9、左眼9、双眼11。

临床怎么用

  • 该iPad应用可用于帮助青光眼患者直观理解并描述其视野缺损,提升疾病认知。
  • 临床可将Humphrey视野数据通过该工具转化为患者可感知的模糊程度,辅助医患沟通。

局限性

  • 样本量较小(12例),需更大样本验证。
  • 仅纳入视力≥20/40且视野稳定可靠的患者,结果可能不适用于所有青光眼患者。
  • 未报告应用的重测信度或长期随访数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Glaucoma patients with peripheral vision loss have in the past subjectively described their field loss as 'blurred' or 'no vision compromise'. We developed an iPad app for patients to self-characterise perception within areas of glaucomatous visual field loss. METHODS: Twelve glaucoma patients with visual acuity ≥20/40 in each eye, stable and reliable Humphrey Visual Field (HVF) over 2 years were enrolled. An iPad app (held at 33 cm) allowed subjects to modify 'blur' or 'dimness' to match their perception of a 2×2 m wall-mounted poster at 1 m distance. Subjects fixated at the centre of the poster (spanning 45° of field from centre). The output was degree of blur/dim: normal, mild and severe noted on the iPad image at the 54 retinal loci tested by the HVF 24-2 and was compared to threshold sensitivity values at these loci. Monocular (Right eye (OD), left eye (OS)) HVF responses were used to calculate an integrated binocular (OU) visual field index (VFI). All three data sets were analysed separately. RESULTS: 36 HVF and iPad responses from 12 subjects (mean age 71±8.2y) were analysed. The mean VFI was 77% OD, 76% OS, 83% OU. The most common iPad response reported was normal followed by blur. No subject reported dim response. The mean HVF sensitivity threshold was significantly associated with the iPad response at the corresponding retinal loci (For OD, OS and OU, respectively (dB): normal: 23, 25, 27; mild blur: 18, 16, 22; severe blur: 9, 9, 11). On receiver operative characteristic (ROC) curve analysis, the HVF retinal sensitivity cut-off at which subjects reported blur was 23.4 OD, 23 OS and 23.3 OU (dB). CONCLUSIONS: Glaucoma subjects self-pictorialised their field defects as blur; never dim or black. Our innovation allows translation of HVF data to quantitatively characterise visual perception in patients with glaucomatous field defects.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Gagrani M, Ndulue J, Anderson D, et al. What do patients with glaucoma see: a novel iPad app to improve glaucoma patient awareness of visual field loss. Br J Ophthalmol. 2020. PMID: 33218992. doi:10.1136/bjophthalmol-2020-317034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。