角膜刚度参数可预测青光眼可疑眼的结构与功能进展
结果显示,较高SP-A1且较薄CCT的眼RNFL变薄更快、视野进展风险更高,角膜刚度参数与CCT协同作为进展危险因素。
要点
- 角膜刚度参数SP-A1较高且CCT较薄的眼,RNFL变薄加速0.72 μm/年。
- 上述眼别快速RNFL进展(>1 μm/年)的似然比高2.9倍。
- 较高SP-A1且较薄CCT的眼视野进展风险高3.7倍。
核心结论
- 角膜刚度参数较高且CCT较低(薄而硬的角膜)的青光眼可疑眼进展风险更大。
- 角膜刚度参数似乎与CCT协同作为青光眼进展的危险因素。
研究设计与样本
- 基线用Corvis ST测量角膜刚度参数,每6个月随访临床检查、HVF和OCT,平均随访4.2年。
主要发现
- SP-A1较高与RNFL变薄更快相关(P < 0.001),并与较薄CCT协同(P = 0.004)。
- 较高SP-A1且较薄CCT的眼相对较低SP-A1且较厚CCT的眼,RNFL变薄加速0.72 μm/年(95%CI 0.17-1.28;P = 0.011)。
- 较高SP-A1且较薄CCT的眼快速RNFL进展(>1 μm/年)的似然比高2.9倍(95%CI 1.4-6.1;P = 0.006)。
- GCIPL变薄结果与RNFL一致。
- 较高SP-A1与视野进展风险更高相关(P = 0.002),并与较薄CCT协同(P = 0.010);较高SP-A1且较薄CCT的眼视野进展风险高3.7倍(95%CI 1.3-10.5;P = 0.014)。
临床怎么用
- 对青光眼可疑眼,可考虑用Corvis ST测量角膜刚度参数,结合CCT评估进展风险。
- 角膜薄且刚度参数高的可疑眼可能需要更密切随访。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate corneal stiffness parameters (SPs) as predictors of future progression risk in glaucoma suspect eyes. DESIGN: Prospective, longitudinal study. PARTICIPANTS: Three hundred seventy-one eyes from 228 primary open-angle glaucoma suspects, based on optic disc appearance, with normal baseline Humphrey Visual Field (HVF; Carl Zeiss Meditec) results. METHODS: Baseline corneal SPs were measured using Corvis ST (Oculus Optikgeräte GmbH). Participants were followed up every 6 months with clinical examination, HVF testing, and OCT. The baseline SP at first applanation (SP-A1) and highest concavity predicted the prospective outcome measures. MAIN OUTCOME MEASURES: Structural progression was measured by the OCT rate of thinning of the retinal nerve fiber layer (RNFL) and ganglion cell-inner plexiform layer (GCIPL). Functional progression was assessed by permutation analysis of pointwise linear regression criteria on HVF testing. RESULTS: Stiffness parameters correlated positively with central corneal thickness (CCT), which was adjusted for in all analyses. A higher SP-A1, suggestive of a stiffer cornea, was associated with a faster rate of RNFL thinning (P < 0.001), synergistic with thinner CCT (P = 0.004) over a mean follow-up of 4.2 years. Eyes with higher SP-A1 and thinner CCT (thin and stiff corneas) showed accelerated RNFL thinning by 0.72 μm/year relative to eyes with lower SP-A1 and thicker CCT (95% confidence interval [CI], 0.17-1.28; P = 0.011) and were at 2.9-fold higher likelihood of fast RNFL progression of more than 1 μm/year (95% CI, 1.4-6.1; P = 0.006). Consistent results also were observed with GCIPL thinning. Furthermore, a higher SP-A1 was associated with a greater risk of visual field progression (P = 0.002), synergistic with thinner CCT (P = 0.010). Eyes with higher SP-A1 and thinner CCT were at 3.7-fold greater risk of visual field progression relative to eyes with thicker CCT and lower SP-A1 (95% CI, 1.3-10.5; P = 0.014). CONCLUSIONS: Glaucoma suspect eyes with higher corneal SPs and lower CCT, suggestive of thin and stiff corneas, are at greater risk of progression. Corneal SPs seem to act synergistically with CCT as risk factors for glaucoma progression.
引用
- Qassim A, Mullany S, Abedi F, et al. Corneal Stiffness Parameters Are Predictive of Structural and Functional Progression in Glaucoma Suspect Eyes. Ophthalmology. 2020. PMID: 33245936. doi:10.1016/j.ophtha.2020.11.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。