宽场SD-OCT角膜亚层厚度测量鉴别透明边缘变性圆锥角膜
这项前瞻性横断面研究纳入69眼(圆锥角膜59眼、透明边缘变性10眼),用RTVue XR系统重复测量角膜总厚度、上皮厚度和基质厚度图。透明边缘变性在颞下2-5mm扇区总厚度和上皮厚度高于圆锥角膜,颞下2-5mm与下方7-9mm总厚度比值鉴别两者AUC为0.977,最佳截断值0.90。
要点
- 宽场SD-OCT角膜亚层厚度测量在圆锥角膜和透明边缘变性中重复性均良好。
- 透明边缘变性颞下2-5mm扇区总厚度和上皮厚度高于圆锥角膜。
- 颞下2-5mm与下方7-9mm总厚度比值鉴别两者AUC达0.977,截断值0.90。
核心结论
- 宽场SD-OCT角膜亚层厚度测量在透明边缘变性和圆锥角膜中可靠性良好,可能有助于鉴别这两种扩张性疾病。
研究设计与样本
- 前瞻性横断面研究纳入69例患者69眼,其中圆锥角膜59眼、透明边缘变性10眼,均用RTVue XR系统连续检查三次。
主要发现
- 圆锥角膜组ICC为0.827至0.986,透明边缘变性组ICC为0.753至0.998,重复性均良好。
- 圆锥角膜眼测量可靠性随Kmax增大而下降(p<0.05)。
- 透明边缘变性颞下2-5mm扇区总厚度526±31µm高于圆锥角膜503±30µm(p=0.02)。
- 透明边缘变性颞下2-5mm扇区上皮厚度56±7µm高于圆锥角膜51±5µm(p=0.02)。
- 透明边缘变性下方7-9mm扇区上皮厚度52±5µm低于圆锥角膜57±5µm(p<0.01)。
关键数值与推荐
- 颞下2-5mm与下方7-9mm总厚度比值鉴别透明边缘变性与圆锥角膜的AUC为0.977,最佳截断值0.90。
临床怎么用
- 临床可用宽场SD-OCT角膜亚层厚度图,结合颞下2-5mm与下方7-9mm总厚度比值辅助鉴别透明边缘变性与圆锥角膜。
局限性
- 透明边缘变性样本仅10眼,样本量较小。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the capability of wide-field spectral-domain optical coherence tomography (SD-OCT) corneal sublayer pachymetry to distinguish between keratoconus and pellucid marginal degeneration (PMD). METHODS: This prospective cross-sectional study included 69 eyes (59 with keratoconus and 10 with PMD) of 69 patients. All patients were examined three subsequent times with the RTVue XR system. Pachymetry maps of the total cornea (CT), the epithelium (ET) and the stroma were generated using the onboard software. For analysis of reliability, the coefficients of variation and intraclass correlation coefficients (ICC) were calculated. Receiver operating characteristic analyses were performed to elaborate the most accurate pachymetric parameters for distinguishing between PMD and keratoconus. RESULTS: Overall repeatability of (sublayer) pachymetry was comparably good in both keratoconus (ICC ranging between 0.827 and 0.986) and PMD (ICC ranging between 0.753 and 0.998). Measurement reliability in keratoconic eyes was a negative function of Kmax (p<0.05). As compared with keratoconus, PMD exhibited higher CT (526±31 µm vs 503±30 µm; p=0.02) and ET (56±7 µm vs 51±5 µm; p=0.02) in the inferotemporal 2-5 mm sector as well as lower ET in the inferior 7-9 mm sector (52±5 µm vs 57±5 µm; p<0.01). The calculated ratio between CT in the inferotemporal 2-5 mm and in the inferior 7-9 mm sector yielded the highest diagnostic accuracy for distinguishing between PMD and keratoconus with an area under the curve of 0.977 and an optimal cut-off value of 0.90. CONCLUSION: Wide-field SD-OCT corneal sublayer pachymetry showed good reliability in PMD and keratoconus and may be useful to differentiate between the two ectatic diseases.
引用
- Mohr N, Shajari M, Krause D, et al. Pellucid marginal degeneration versus keratoconus: distinction with wide-field SD-OCT corneal sublayer pachymetry. Br J Ophthalmol. 2020. PMID: 33055086. doi:10.1136/bjophthalmol-2020-316496
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。