文献速递角膜与眼表疾病眼底病与葡萄膜炎

B超、视觉电生理与围手术期视频内镜预测人工角膜术后功能结果

B-scan ultrasound, visual electrophysiology and perioperative videoendoscopy for predicting functional results in keratoprosthesis candidates.
PubMed 文献 · Br J Ophthalmol · 2020-10-22

这项前瞻性干预研究纳入13例已计划行Boston 1型人工角膜手术的患者,术前进行B超、电生理检查和围手术期内眼视频内镜评估,并按预设标准分为有利或不利预测。术后1年10眼(76.9%)BCVA优于20/200,5眼(38.5%)达20/40或更好;内镜阴性预测满意视力的PPV为100%,优于B超(85.7%)和电生理(66.7%)。

要点

  • 内眼视频内镜阴性预测术后满意视力的PPV达100%,优于B超和电生理。
  • 术后1年76.9%眼BCVA优于20/200,38.5%眼达20/40或更好。
  • B超预测满意视力的PPV为85.7%,ERG和VEP均为66.7%。

核心结论

  • 内眼视频内镜可直接观察眼底,是预测人工角膜候选者功能结局的微创方法,预后判断优于B超和电生理检查。

研究设计与样本

  • 前瞻性干预研究,纳入13例已计划行Boston 1型人工角膜手术的个体,术前完成眼科评估、B超、电生理检查和围手术期视频内镜评估。

主要发现

  • 术后1年BCVA优于20/200者10眼(76.9%),达20/40或更好者5眼(38.5%)。
  • B超预测满意术后视力的PPV为85.7%,视网膜电图(ERG)PPV为66.7%,视觉诱发电位(VEP)PPV为66.7%。
  • 围手术期视频内镜阴性预测满意视力的PPV为100%。

关键数值与推荐

  • B超、电生理和视频内镜结果按预设标准分为术后功能结果的有利或不利预测因素。
  • 满意视力结果定义为术后1年BCVA优于20/200。

临床怎么用

  • 对人工角膜候选者,可考虑围手术期视频内镜评估眼底可视性以辅助预测术后功能结局。

局限性

  • 样本量仅13例,结论需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: We analysed the ability of B-scan ultrasound, ocular electrophysiology testing and videoendoscopic examination for predicting visual prognosis in Boston Type 1 keratoprosthesis (KPro-1) candidates. Indirect anatomical and electrophysiological findings and results from direct endoscopic evaluations were correlated with postoperative functional data. METHODS: In this prospective and interventional study, we included 13 individuals who had previously been indicated for Kpro-1 surgery. All subjects underwent preoperative screening, including ophthalmic evaluation, B-scan ultrasound, electrophysiological testing, and perioperative intraocular videoendoscopic evaluation (VE). B-scan ultrasound, electrophysiological testing, and VE evaluation results were categorised as favourable or unfavourable predictors of postoperative functional results according to predefined criteria. The predictability values of B-scan ultrasound, electrophysiological testing, and VE prognostication were calculated based on the visual acuity level achieved. RESULTS: All surgeries and perioperative VEs were uneventful. Preoperative best-corrected visual acuity (BCVA) ranged from light perception to counting fingers. The 1-year postoperative BCVA was better than 20/200 (satisfactory visual acuity result) in 10 eyes (76.9%) and 20/40 or better in 5 eyes (38.5%). B-scan ultrasound presented a positive predictive value (PPV) of 85.7% for satisfactory postoperative visual acuity, electroretinography showed a PPV of 66.7%, and visual evoked potential presented a PPV of 66.7%. The perioperative VE PPV of a negative finding for satisfactory visual acuity was 100%. CONCLUSIONS: Fundoscopic visualisation by intraocular VE is a minimally invasive procedure that can be used to predict functional outcomes in keratoprosthesis candidates. This technique demonstrated better prognostication in keratoprosthesis candidates than B-scan ultrasound and electrophysiological testing.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Silva LD, Santos A, Hirai F, et al. B-scan ultrasound, visual electrophysiology and perioperative videoendoscopy for predicting functional results in keratoprosthesis candidates. Br J Ophthalmol. 2020. PMID: 33093153. doi:10.1136/bjophthalmol-2020-316962

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。