文献速递角膜与眼表疾病眼整形与眼眶

室内空气微生物浓度与干眼症的关联研究

Indoor Airborne Microbial Concentration and Dry Eye.
PubMed 文献 · Am J Ophthalmol · 2020-10-14

该前瞻性横断面研究纳入157名眼外部解剖正常的受试者,评估室内空气微生物浓度与干眼症状和体征的关联。研究发现,在调整年龄和性别后,室内空气微生物菌落数与角膜上皮损伤和睑板腺缺失显著相关,且菌落数与年龄仍与睑板腺缺失显著相关。结论提示家庭微生物暴露可能影响睑板腺缺失,或可成为干预靶点。

要点

  • 家庭空气微生物菌落数越高,睑板腺缺失越严重。
  • 菌落数与角膜上皮损伤和睑板腺缺失显著相关。
  • 湿度增加与营养培养基菌落数增加相关。

核心结论

  • 家庭空气微生物菌落数较高的个体,在调整年龄和其他混杂因素后,睑板腺缺失更严重。
  • 该发现提示家庭微生物暴露可能影响睑板腺缺失这一干眼指标,或可成为干预靶点。

研究设计与样本

  • 前瞻性、观察性、横断面研究,从迈阿密退伍军人事务眼科诊所招募157名眼外部解剖正常的受试者。
  • 受试者接受干眼症状和体征的临床评估,并使用生物气溶胶撞击器采集室内空气样本,分别用营养培养基和大豆培养基,在37°C、5% CO2条件下培养48小时,记录微生物菌落数(CFU)。
  • 157名受试者参与家庭和临床访视,其中93人完成了6个月的家庭和临床随访。

主要发现

  • 较旧的房屋相比新房屋具有更高的CFU。
  • 湿度每增加1%,营养培养基CFU增加3%(95% CI = 0.01至0.04;P < .001)。
  • 仪器测量的CFU与两项干眼指标显著相关:角膜上皮损伤和 lower eyelid meibomian gland (MG) dropout,调整年龄和性别后,大豆培养基的比值比分别为OR = 28.07(95% CI = 1.8, 443.8,P < .05)和OR = 39.6(95% CI = 1.8, 875.2,P < .05)。
  • 调整其他混杂因素后,CFU和年龄仍与睑板腺缺失显著相关。
  • 其他干眼指标与CFU无显著关联。

关键数值与推荐

  • 湿度每增加1%,营养培养基CFU增加3%(95% CI = 0.01至0.04;P < .001)。
  • 大豆培养基CFU与角膜上皮损伤的OR = 28.07(95% CI = 1.8, 443.8,P < .05),调整年龄和性别。
  • 大豆培养基CFU与 lower eyelid meibomian gland dropout 的OR = 39.6(95% CI = 1.8, 875.2,P < .05),调整年龄和性别。

临床怎么用

  • 对于干眼患者,尤其是睑板腺缺失严重者,可考虑评估家庭环境微生物暴露情况。
  • 控制室内湿度和微生物浓度可能作为干眼管理的潜在干预方向,但需进一步研究验证。

局限性

  • 本研究为横断面设计,无法确定因果关系。
  • 样本来自单一退伍军人眼科诊所,可能存在选择偏倚。
  • 随访6个月期间失访率较高(157人中仅93人完成随访)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To examine associations between indoor airborne microbial concentration and dry eye (DE) measures. DESIGN: Prospective, observational, cross-sectional study. METHODS: A total of 157 individuals with normal external ocular anatomy were recruited from the Miami Veterans Affairs eye clinic. Subjects underwent a clinical evaluation that included assessment of DE symptoms and signs. Indoor air was sampled using bioaerosol impactors with nutrient and soy media, and samples were incubated for 48 hours at 37 C with 5% CO2. Number of microbial colonies (CFU) was recorded. Outcome measures were DE symptoms and signs. RESULTS: A total of 157 unique subjects participated in home and clinical visits and of these, 93 completed a 6-month follow-up of home and clinical visits. Older homes were found to have higher CFU compared to newer homes. A 1% increase in humidity was associated with a 3% increase in nutrient CFU (95% confidence interval [CI] = 0.01 to 0.04; P < .001). Instrumented CFU significantly associated with 2 DE measures: corneal epithelial disruption and lower eyelid meibomian gland (MG) dropout, adjusted for age and sex (odds ratio [OR] = 28.07, 95% CI =1.8, 443.8, P < .05; OR = 39.6, CI = 1.8, 875.2, P < .05 for soy, respectively). After adjusting for other confounders, CFU and age remained significantly associated with MG dropout. Other DE measures did not significantly associate with CFU. CONCLUSIONS: Individuals with higher CFU counts in the home had more severe MG dropout, after adjusting for age and other confounders. This finding suggests that home CFU exposure may impact MG dropout, one of the DE measures, and may be a target for intervention.