文献速递角膜与眼表疾病白内障与屈光手术

角膜直径对Pentacam BAD系统角膜扩张分析的影响

[The influence of different corneal diameters on Belin/Ambrósio enhanced ectasia display of Pentacam corneal topography].
PubMed 文献 · Zhonghua Yan Ke Za Zhi · 2020-01-01

结果显示角膜直径对BAD参数影响显著,小角膜组Df、Db、Dp、Da、Do均值更高,可疑和病理比例也最高,提示小角膜者假阳性率较高。

要点

  • 角膜直径对BAD系统参数Df、Db、Dp、Dt、Da、Do均有显著影响(P<0.01)。
  • 小角膜组(≤11.1 mm)各BAD参数均值最高,可疑和病理比例也最高。
  • 解读BAD结果时应考虑角膜直径,小角膜者需警惕假阳性。

核心结论

  • 角膜直径对BAD系统关于角膜扩张分析的结果影响显著。
  • 与大角膜者相比,小角膜者分析结果出现假阳性的比例较高。

研究设计与样本

  • 采用单因素方差分析比较BAD参数,卡方检验比较正常、可疑及病理分布。

主要发现

  • A、B、C组Df分别为0.73±1.14、0.48±1.02、0.11±0.91,Db分别为1.09±1.07、0.23±0.83、-0.34±0.62。
  • A、B、C组Dp分别为1.57±0.91、1.14±0.86、0.68±0.75,Dt分别为-0.11±0.84、-0.02±0.82、0.03±0.78。
  • A、B、C组Da分别为0.78±0.61、0.64±0.64、0.48±0.64,Do分别为1.65±0.64、1.24±0.60、0.86±0.55。
  • Df(F=129.549)、Db(F=829.491)、Dp(F=344.373)、Dt(F=7.249)、Da(F=68.637)、Do(F=524.877)组间差异均有统计学意义(P<0.01)。
  • Df(χ²=161.8)、Db(χ²=611.75)、Dp(χ²=478.84)、Da(χ²=44.636)、Do(χ²=553.11)可疑和病理比例分布差异均有统计学意义(P<0.01),且均是A组占比最高。

临床怎么用

  • 临床解读Pentacam BAD结果时应结合角膜直径,避免小角膜者被过度诊断为可疑或病理。
  • 对小角膜患者,BAD参数轻度异常时需结合其他检查综合判断,降低假阳性风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the effect of corneal diameter on Belin/Ambrósio enhanced ectasia display (BAD). Methods: Retrospective case series study. The subjects were 6 744 myopic patients, including 3 341 males and 3 403 females, who had undergone corneal refractive surgery or had completed preoperative examination but had not undergone corneal refractive surgery at the Army Medical Center and Chongqing Vision Institute in Chongqing from June 2017 to June 2019. Age was (23.74±5.73) years old. No patients had keratoconus. One eye of each patient was randomly included, and the patients were divided into groups according to the corneal diameter measured by Pentacam. Group A included 630 patients (630 eyes) with corneal diameter ≤ 11.1 mm. In group B, there were 4 063 patients (4 063 eyes) with corneal diameter of 11.2 to 11.8 mm. In group C, there were 2 051 patients (2 051 eyes) with corneal diameter ≥11.9 mm. Preoperative BAD parameters of deviation of front elevation difference map (Df), deviation of back elevation difference map (Db), deviation of average pachymetric progression index (Dp), deviation of minimum thickness (Dt), deviation of Ambrósio's relational thickness maximum (Da) and overall deviation value (Do) were measured by Pentacam. One-way analysis of variance was used for preoperative BAD parameters comparison between groups. The distribution of normal, suspicious and pathological results of Df, Db, Dp, Dt, Da and Do in each group was tested by chi-square test. Results: In groups A, B and C, Df was 0.73±1.14, 0.48±1.02, and 0.11±0.91, Db was 1.09±1.07, 0.23±0.83, and-0.34±0.62, Dp was 1.57±0.91, 1.14±0.86, and 0.68±0.75, Dt was -0.11±0.84, -0.2±0.82, and 0.03±0.78, Da was 0.78±0.61, 0.64±0.64, and 0.48±0.64, and Do was 1.65±0.64, 1.24±0.60, and 0.86±0.55, respectively. The BAD parameters of Df (F=129.549), Db (F=829.491), Dp (F=344.373), Dt (F=7.249), Da (F=68.637) and Do (F=524.877) were all significantly different between groups (P<0.01). The proportion of suspicious and pathological BAD parameters [Df (χ²=161.8), Db (χ²=611.75), Dp (χ²=478.84), Da (χ²=44.636), and Do (χ²=553.11)] suggested the distribution in each group was significantly different (P<0.01). Conclusions: Corneal diameter had a significant influence on BAD. Compared with eyes with large corneas, the false positive rate of BAD was higher in eyes with small corneas.(Chin J Ophthalmol, 2020, 56: 761-767). 目的: 探讨角膜直径对Pentacam角膜地形图中Belin/Ambrósio增强扩张显示(BAD)系统关于角膜扩张分析结果的影响。 方法: 回顾性系列病例研究。研究对象为2017年6月至2019年6月在陆军特色医学中心和重庆眼视光眼科医院已行角膜屈光手术或拟行角膜屈光手术但已完成术前检查的近视眼患者6 744例,其中男性3 341例,女性3 403例;年龄(23.74±5.73)岁。所有患者排除圆锥角膜,采用计算机随机法纳入单眼进行研究。患者按角膜直径进行分组,A组为角膜直径≤11.1 mm者,共630例(630只眼);B组为角膜直径11.2~11.8 mm者,共4 063例(4 063只眼);C组为角膜直径≥11.9 mm者,共2 051例(2 051只眼)。所有患者术前采用Pentacam角膜地形图中的BAD角膜扩张分析功能检测角膜前表面高度偏差值(Df)、后表面高度偏差值(Db)、平均厚度进展偏差值(Dp)、最薄点厚度偏差值(Dt)、Ambrósio厚度最大变化率偏差值(Da)和总偏差值(Do)等参数。术前3个组的角膜地形图指标组间比较采用单因素方差分析;各指标的正常、可疑及病理情况分布比较采用卡方检验。 结果: A、B、C组BAD系统相关指标结果分别为Df:0.73±1.14、0.48±1.02、0.11±0.91、Db:1.09±1.07、0.23±0.83、-0.34±0.62;Dp:1.57±0.91、1.14±0.86、0.68±0.75;Dt:-0.11±0.84、-0.02±0.82、0.03±0.78;Da:0.78±0.61、0.64±0.64、0.48±0.64;Do:1.65±0.64、1.24±0.60、0.86±0.55。3个组BAD系统相关指标Df(F=129.549)、Db(F=829.491)、Dp(F=344.373)、Dt(F=7.249)、Da(F=68.637)、Do(F=524.877)比较差异均有统计学意义(P<0.01)。3个组Df(χ²=161.8)、Db(χ²=611.75)、Dp(χ²=478.84)、Da(χ²=44.636)、Do(χ²=553.11)可疑和病理的比例分布差异均有统计学意义(P<0.01),且均是A组占比最高。 结论: 角膜直径对BAD系统关于角膜扩张分析的结果影响显著;与大角膜者相比,小角膜者分析结果出现假阳性的比例较高。(中华眼科杂志,2020,56:761-767).

来源:Zhonghua Yan Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Cao KW, Liu LN, Sun YL, et al. [The influence of different corneal diameters on Belin/Ambrósio enhanced ectasia display of Pentacam corneal topography]. Zhonghua Yan Ke Za Zhi. 2020. PMID: 33059419. doi:10.3760/cma.j.cn112142-20200220-00093

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。