文献速递眼底病与葡萄膜炎白内障与屈光手术

25G与27G无缝线套管式人工晶状体巩膜固定术的视力结果与并发症比较

COMPARISON OF 25- AND 27-GAUGE SUTURELESS CANNULA-BASED INTRAOCULAR LENS SCLERAL FIXATION VISUAL ACUITY OUTCOMES AND COMPLICATION RATES.
PubMed 文献 · Retina · 2021-01-01

回顾性比较无囊膜支撑眼行25G与27G无缝线套管式人工晶状体巩膜固定术(SCILS)的视力与并发症。27G组术后1周视力即显著改善,25G组同期显著恶化。27G组人工晶状体移位和再手术率显著更低。

要点

  • 27G组术后第1周视力即显著改善(P<0.01),25G组同期显著恶化(P=0.01)。
  • 27G组人工晶状体移位(P=0.01)和再手术需求(P=0.01)均显著低于25G组。
  • 两组术后1年视力均呈改善趋势,25G组logMAR从0.95±0.68降至0.67±0.64。

核心结论

  • 与25G SCILS固定相比,27G SCILS固定眼视力改善更迅速。
  • 27G组并发症发生率更低,包括人工晶状体移位和再手术需求。

研究设计与样本

  • 回顾性病历审查,纳入无囊膜支撑、接受三片式人工晶状体SCILS固定的连续病例。
  • 25G组27眼,27G组42眼,共69眼;经结膜使用25G或27G穿刺套管完成手术。

主要发现

  • 25G组术前平均logMAR视力0.95±0.68(Snellen约20/178),术后1年0.67±0.64(约20/94)。
  • 27G组术前平均logMAR视力1.43±0.94(Snellen约20/538),术后1年0.86±1.00(约20/145)。
  • 27G组术后第1周视力即显著改善(P<0.01),25G组同期显著恶化(P=0.01)。
  • 27G组人工晶状体移位(P=0.01)和再手术需求(P=0.01)显著减少。

临床怎么用

  • 对于无囊膜支撑需行巩膜固定人工晶状体的眼,27G SCILS可能带来更快的视力恢复和更低的再手术风险。
  • 术后早期应关注25G组可能出现的视力暂时恶化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the visual outcomes and complication rates of sutureless cannula-based intraocular lens scleral (SCILS) fixation performed with 25-gauge (25 G) versus 27-gauge (27 G) instrumentation. METHODS: A retrospective chart review of consecutive cases of eyes without capsular support that underwent SCILS fixation of a three-piece intraocular lens. Sutureless cannula-based intraocular lens scleral fixation was performed by transconjunctival use of either 25-G or 27-G trocar cannulas. During postoperative follow-up evaluations, visual acuity and intraocular pressure were measured, and slit-lamp and indirect ophthalmoscopy examinations were performed to assess for development of known complications. RESULTS: A total of 69 eyes underwent 25 G (27 eyes) or 27 G (42 eyes) SCILS fixation. The mean preoperative logarithm of the minimum angle of resolution visual acuity trended toward improvement from 0.95 ± 0.68 (20/178 Snellen equivalent) to 0.67 ± 0.64 (20/94 Snellen equivalent) for 25 G group at 1 year. Similar trend toward visual acuity improvement was seen in 27 G group with a mean preoperative logarithm of the minimum angle of resolution visual acuity of 1.43 ± 0.94 (20/538 Snellen equivalent) improving to 0.86 ± 1.00 (20/145 Snellen equivalent) at 1 year. Statistically significant improvement was seen as early as postoperative week one for 27 G group (P < 0.01), whereas statistically significant worsening was noted at the same time in 25 G group (P = 0.01). There was a statistically significant reduction in intraocular lens displacement (P = 0.01) and need for reoperation (P = 0.01) in 27 G group. CONCLUSION: Compared with 25 G SCILS fixation, eyes managed with 27 G SCILS fixation experienced more rapid visual acuity improvement. In addition, there was a lower rate of complications including intraocular lens displacement and need for reoperation.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Kadakia AB, Wong TP, Wykoff CC, et al. COMPARISON OF 25- AND 27-GAUGE SUTURELESS CANNULA-BASED INTRAOCULAR LENS SCLERAL FIXATION VISUAL ACUITY OUTCOMES AND COMPLICATION RATES. Retina. 2021. PMID: 33009221. doi:10.1097/IAE.0000000000002991

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。