文献速递青光眼神经眼科

体位改变对非人灵长类眼压、颅内压及跨筛板压力影响的连续无线遥测研究

Effect of Body Position on Intraocular Pressure (IOP), Intracranial Pressure (ICP), and Translaminar Pressure (TLP) Via Continuous Wireless Telemetry in Nonhuman Primates (NHPs).
PubMed 文献 · Invest Ophthalmol Vis Sci · 2020-01-01

本研究在3只雄性非人灵长类眼内和脑实质植入无线压力遥测传感器,连续测量不同体位下的眼压、颅内压及跨筛板压力。结果显示从仰卧到坐位、站立及倒立体位时跨筛板压力显著瞬时改变,且颅内压变化幅度大于眼压,提示体位相关跨筛板压力变化主要由颅内压驱动。

要点

  • 体位改变可瞬时显著改变跨筛板压力,仰卧至坐位增加14 mmHg,仰卧至站立增加13 mmHg,仰卧至倒立降低12 mmHg。
  • 颅内压相对变化幅度大于眼压,跨筛板压力变化主要由颅内压驱动。
  • 仰卧至俯卧位跨筛板压力无显著变化。

核心结论

  • 体位改变引起的跨筛板压力变化主要由颅内压而非眼压驱动。

研究设计与样本

  • 在3只雄性非人灵长类眼内和脑实质植入无线压力遥测传感器,以200 Hz连续测量眼压、颅内压及跨筛板压力,每体位取30秒平均值。

主要发现

  • 从仰卧到坐位跨筛板压力增加14 mmHg,从仰卧到站立增加13 mmHg,从仰卧到倒立降低12 mmHg,差异均显著(P < 0.05)。
  • 仰卧到俯卧位跨筛板压力无显著变化。
  • 颅内压相对变化幅度大于眼压。

临床怎么用

  • 临床评估青光眼风险时需考虑体位对跨筛板压力的影响,尤其是颅内压变化的主导作用。

局限性

  • 研究仅纳入3只雄性非人灵长类,样本量小,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Recent retrospective clinical studies and animal experiments have suggested that cerebrospinal fluid pressure (CSFP) is important in glaucoma, acting through the translaminar pressure (TLP = IOP - CSFP), which directly affects the optic nerve head. In this study, IOP and intracranial pressure (ICP; a surrogate of CSFP) were measured at various body positions to quantify the determinants of TLP. METHODS: We have developed an implantable wireless pressure telemetry system based on a small piezoelectric sensor with low temporal drift. Telemetry transducers were placed in the anterior chamber to measure IOP and in the brain parenchyma at eye height to measure ICP. IOP was calibrated against anterior cannulation manometry, and ICP/CSFP was calibrated against an intraparenchymal Codman ICP Express microsensor. We measured IOP, ICP, and TLP = IOP - ICP continuously at 200 Hz in three male nonhuman primates (NHPs) in three trials; pressures were then averaged for 30 seconds per body position. Relative change of IOP, ICP, and TLP from the supine (baseline) position to the seated, standing, and inverted positions were quantified. RESULTS: TLP changed significantly and instantaneously from the supine to seated (+14 mm Hg), supine to standing (+13 mm Hg) and supine to inverted (-12 mm Hg) positions (P < 0.05). There was no significant TLP change for supine to prone. ICP showed greater relative change than IOP. CONCLUSIONS: TLP change due to body position change is driven more by ICP/CSFP than IOP. IOP, ICP, and TLP variability, coupled with telemetry, should allow us to test the hypotheses that IOP, ICP, or TLP fluctuations contribute independently to glaucoma onset or progression.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Jasien JV, Samuels BC, Johnston JM, et al. Effect of Body Position on Intraocular Pressure (IOP), Intracranial Pressure (ICP), and Translaminar Pressure (TLP) Via Continuous Wireless Telemetry in Nonhuman Primates (NHPs). Invest Ophthalmol Vis Sci. 2020. PMID: 33074300. doi:10.1167/iovs.61.12.18

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。