眼压升高时筛板毛细血管变直
研究对3只猪眼灌注荧光染料标记毛细血管,在5至50毫米汞柱眼压下成像筛板毛细血管和胶原梁,测量毛细血管迂曲度。结果显示15毫米汞柱时毛细血管高度迂曲,眼压从15升至25毫米汞柱时多数眼迂曲度显著下降,从15升至40毫米汞柱时所有眼迂曲度显著下降。作者推测筛板毛细血管迂曲度可提供松弛余量,低迂曲度可能是高眼压下损伤的危险因素。
要点
- 猪眼筛板毛细血管在15毫米汞柱时高度迂曲,迂曲度可达1.45。
- 眼压从15升至25毫米汞柱时,除一只眼外其余眼毛细血管迂曲度显著下降(P < 0.01)。
- 眼压从15升至40毫米汞柱时,每只眼毛细血管迂曲度均显著下降(P < 0.01)。
核心结论
- 筛板毛细血管迂曲度随眼压升高而下降,可能为高眼压下减少血流和结构损伤提供松弛余量。
- 作者推测低毛细血管迂曲度可能是高眼压下损伤的危险因素。
研究设计与样本
- 离体猪眼研究,在处死后8小时内经眼外动脉插管灌注PBS去血,再灌注荧光染料标记毛细血管。
- 每只眼后极部安装于定制充气腔,在5至50毫米汞柱之间每5毫米汞柱递增眼压,用结构光照明显微成像观察毛细血管和胶原梁。
- 共3只猪头,测量毛细血管迂曲度(路径长度除以直线端到端长度),用配对双样本t检验评估眼压变化相关的显著改变。
主要发现
- 毛细血管在15毫米汞柱时高度迂曲,迂曲度可达1.45。
- 除一只眼外,所有眼在眼压从15升至25毫米汞柱时迂曲度显著下降(P < 0.01)。
- 所有眼在眼压从15升至40毫米汞柱时迂曲度显著下降(P < 0.01)。
- 仅16%的毛细血管迂曲度随眼压升高而增加。
- 毛细血管与胶原梁的拓扑结构出乎意料地不同。
临床怎么用
- 提示临床关注筛板毛细血管迂曲度作为高眼压下视神经损伤的潜在生物力学因素。
- 眼压升高时毛细血管迂曲度下降可能影响血流,需进一步研究其与青光眼损伤的关系。
局限性
- 研究为离体猪眼,样本量小(3只猪头),结果外推到人眼需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose of this study was to visualize the lamina cribrosa (LC) capillaries and collagenous beams, measure capillary tortuosity (path length over straight end-to-end length), and determine if capillary tortuosity changes when intraocular pressure (IOP) increases. METHODS: Within 8 hours of sacrifice, 3 pig heads were cannulated via the external ophthalmic artery, perfused with PBS to remove blood, and then perfused with a fluorescent dye to label the capillaries. The posterior pole of each eye was mounted in a custom-made inflation chamber for control of IOP with simultaneous imaging. Capillaries and collagen beams were visualized with structured light illumination enhanced imaging at IOPs from 5 to 50 mm Hg at each 5 mm Hg increment. Capillary tortuosity was measured from the images and paired two-sample t-tests were used to assess for significant changes in relation to changes in IOP. RESULTS: Capillaries were highly tortuous at 15 mm Hg (up to 1.45). In all but one eye, tortuosity decreased significantly as IOP increased from 15 to 25 mm Hg (P < 0.01), and tortuosity decreased significantly in every eye as IOP increased from 15 to 40 mm Hg (P < 0.01). In only 16% of capillaries, tortuosity increased with elevated IOP. Capillaries had a surprisingly different topology from the collagen beams. CONCLUSIONS: Although high capillary tortuosity is sometimes regarded as potentially problematic because it can reduce blood flow, LC capillary tortuosity may provide slack that mitigates against reduced flow and structural damage caused by excessive stretch under elevated IOP. We speculate that low capillary tortuosity could be a risk factor for damage under high IOP.
引用
- Brazile BL, Yang B, Waxman S, et al. Lamina Cribrosa Capillaries Straighten as Intraocular Pressure Increases. Invest Ophthalmol Vis Sci. 2020. PMID: 33001158. doi:10.1167/iovs.61.12.2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。