微视野与低亮度视力检测晚期年龄相关性黄斑变性发病的性能
三种视觉功能检测的ROC曲线下面积无显著差异,对新生血管性和萎缩性AMD检测性能有限,一致性仅为中等。
要点
- 微视野、低亮度视力与最佳矫正视力检测晚期AMD发病的AUC无显著差异。
- 检测新生血管性AMD的AUC:低亮度视力0.71、微视野0.82、最佳矫正视力0.57。
- 三种视觉功能检测间一致性仅为中等(κ≥0.24)。
核心结论
- 微视野、低亮度视力和最佳矫正视力对检测晚期AMD最早发病的性能有限。
主要发现
- 检测新生血管性AMD的AUC:低亮度视力0.71、微视野0.82、最佳矫正视力0.57,组间差异无统计学意义(P≥0.126)。
- 检测萎缩性AMD的AUC:低亮度视力0.56、微视野0.62、最佳矫正视力0.56,组间差异无统计学意义(P≥0.126)。
- 三种视觉功能检测间检测新生血管性和萎缩性AMD发病的一致性仅为中等(κ≥0.24)。
关键数值与推荐
- 检测新生血管性AMD的AUC:低亮度视力0.71、微视野0.82、最佳矫正视力0.57。
- 检测萎缩性AMD的AUC:低亮度视力0.56、微视野0.62、最佳矫正视力0.56。
- 三种检测间一致性κ≥0.24。
临床怎么用
- 微视野和低亮度视力对检测晚期AMD最早发病的性能有限,是否优于Amsler网格等自我检测方法尚待确立。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the performance of microperimetry and low-luminance visual acuity for detecting late age-related macular degeneration (AMD) onset. METHODS: Two hundred ninety-two individuals with bilateral large drusen in the Laser Intervention in the Early Stages of AMD study underwent best-corrected visual acuity, low-luminance visual acuity, and microperimetry testing as well as multimodal imaging to detect late (neovascular or atrophic) AMD onset. The performance of the change in the measurement from baseline of each of visual function test for detecting late AMD onset was compared. RESULTS: The area under the receiver operating characteristic curve for detecting neovascular and atrophic AMD onset was not significantly different for low-luminance visual acuity (area under the receiver operating characteristic curve = 0.71 and 0.56, respectively) and microperimetry (area under the receiver operating characteristic curve = 0.82 and 0.62, respectively) compared with best-corrected visual acuity (area under the receiver operating characteristic curve = 0.57 and 0.56, respectively; P ≥ 0.126 for all). There was also only a fair degree of agreement between the three visual function measures for detecting the onset of neovascular and atrophic AMD (κ ≥ 0.24). CONCLUSION: Microperimetry, low-luminance visual acuity, and best-corrected visual acuity demonstrate limited performance for detecting the earliest onset of late AMD. It remains to be established whether they perform better than current methods designed to enable self-detection of neovascular AMD onset, such as Amsler grid testing.
引用
- Wu Z, Luu CD, Hodgson LAB, et al. USING MICROPERIMETRY AND LOW-LUMINANCE VISUAL ACUITY TO DETECT THE ONSET OF LATE AGE-RELATED MACULAR DEGENERATION: A LEAD Study Report. Retina. 2021. PMID: 33009222. doi:10.1097/IAE.0000000000002982
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。