文献速递眼底病与葡萄膜炎白内障与屈光手术

玻璃体切除硅油填充后无晶状体眼的二次囊袋内IOL植入

Secondary in-the-bag Intraocular Lens Implantation in Aphakic Eyes After Vitrectomy and Silicone Oil Tamponade for Rhegmatogenous Retinal Detachment.
PubMed 文献 · Retina · 2023-01-01

本研究纳入14例因孔源性视网膜脱离行玻璃体切除联合硅油填充后无晶状体眼患者,采用新技术重新开放囊袋并植入可折叠单片IOL。13例手术成功,平均随访48.8周,最佳矫正视力与等效球镜显著改善,眼压无变化,IOL位置居中良好。

要点

  • 囊袋重新开放联合囊袋内IOL植入在13/14眼中成功完成。
  • 术后最佳矫正视力与等效球镜显著改善,眼压无变化。
  • IOL倾斜与偏心测量值小,位置居中良好。

核心结论

  • 采用该技术可在多数玻璃体切除硅油填充后无晶状体眼中实现囊袋重新开放与二次囊袋内IOL植入,并获得满意视力预后与IOL位置。

研究设计与样本

  • 纳入2018年9月至2019年9月因孔源性视网膜脱离行初次玻璃体视网膜手术联合硅油填充的14例患者14眼,采用新技术行囊袋重新开放与可折叠单片IOL植入,随访至少24周。

主要发现

  • 13例手术成功完成,1例因后囊膜撕裂行睫状沟固定植入IOL。
  • 平均随访48.8±14.8周(范围24.9-65.9周),最佳矫正视力从术前Snellen 20/76(logMAR 0.63±0.23)提高至术后20/35(logMAR 0.32±0.32),P=0.001。
  • 等效球镜从术前+8.22±4.08 D改善至术后-2.39±1.77 D,P<0.001。
  • 眼压术前15.93±4.40 mmHg、术后16.25±4.25 mmHg,P=0.743,无变化。
  • IOL平均水平倾斜0.5070±0.3319°、垂直倾斜0.4652±0.3465°,水平偏心0.1705±0.1334 mm、垂直偏心0.1712±0.1576 mm。

临床怎么用

  • 对玻璃体切除硅油填充后无晶状体眼,可考虑采用囊袋重新开放技术行二次囊袋内IOL植入,术前需评估后囊膜完整性。

局限性

  • 样本量小(14眼),单中心、非对照研究,随访时间有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To describe a novel technique for capsular bag reopening and secondary in-the-bag intraocular lens (IOL) implantation in aphakic eyes after vitreoretinal surgery and intraocular tamponade. METHODS: We enrolled 14 eyes of 14 patients who underwent primary vitreoretinal surgery with silicone oil tamponade for rhegmatogenous retinal detachment between September 2018 and September 2019. The novel technique was used for capsular bag reopening and foldable single-piece IOL implantation. Patients were followed up at least 24 weeks with routine ophthalmic examinations, corneal endothelial cell density, and IOL tilt and decentration measurement. RESULTS: The procedure was successfully completed in 13 cases; in one case, because of posterior capsular tear, the IOL was implanted with ciliary sulcus fixation. After a mean follow-up of 48.8 ± 14.8 (range, 24.9-65.9) weeks, the best-corrected visual acuity (before 20/76 Snellen, 0.63 ± 0.23 logarithm of the minimum angle of resolution equivalent and after 20/35 Snellen, 0.32 ± 0.32 logarithm of the minimum angle of resolution equivalent; P = 0.001) and spherical equivalent (before +8.22 ± 4.08, after -2.39 ± 1.77 D; P < 0.001) improved, intraocular pressure (before 15.93 ± 4.40, after 16.25 ± 4.25 mmHg; P = 0.743) remained unchanged. The IOL was well centered with a mean horizontal and vertical tilt of 0.5070 ± 0.3319° and 0.4652 ± 0.3465°, respectively, and decentration of 0.1705 ± 0.1334 mm and 0.1712 ± 0.1576 mm, respectively. CONCLUSION: With this technique, capsular bag reopening and secondary in-the-bag IOL implantation could be achieved in most cases with satisfactory visual outcome and IOL position.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Wu K, Zong Y, Yu J, et al. Secondary in-the-bag Intraocular Lens Implantation in Aphakic Eyes After Vitrectomy and Silicone Oil Tamponade for Rhegmatogenous Retinal Detachment. Retina. 2023. PMID: 33003173. doi:10.1097/IAE.0000000000002987

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。