文献速递小儿眼科与斜弱视神经眼科

双眼分视空间对比敏感度反映正常与立体视觉异常受试者的双眼平衡

Dichoptic Spatial Contrast Sensitivity Reflects Binocular Balance in Normal and Stereoanomalous Subjects.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2020-01-01

结果显示,中心注视弱视患者的分视观看显著降低弱视眼CSF而几乎不影响优势眼,对照双眼均受轻度影响。分视CSF或可更可靠地反映弱视眼视觉能力并评估弱视治疗疗效。

要点

  • 中心注视弱视患者分视观看对弱视眼CSF有大幅负面影响,对优势眼几乎无影响。
  • 对照组分视观看对双眼CSF有较小但显著的影响。
  • 分视CSF可能比标准单眼检查更可靠地反映弱视眼视觉能力。

核心结论

  • 分视对比敏感度函数可考虑用于测量双眼视觉改变患者的视觉表现,因其比标准单眼检查更好地反映弱视眼视觉能力。
  • 分视CSF可能也是评估现代弱视治疗疗效的更可靠参数。

研究设计与样本

  • 刺激为亮度噪声背景上的消色差Gabor斑块;单眼刺激时遮盖未测试眼,分视刺激时未测试眼观看背景噪声。
  • 双眼的分视CSF在同一区组内采集。

主要发现

  • 中心注视弱视患者中,分视观看对弱视眼CSF有大幅负面影响,而几乎不影响优势眼。
  • 对照组分视观看对双眼均有较小但显著的影响。
  • 所有参与者按双眼受分视刺激影响程度呈连续分布,弱视敏感度下降与分视敏感度下降两个预定对比敏感度比值在所有参与者中显著相关。
  • 聚类分析能以最小误差区分两组。

关键数值与推荐

  • 测量空间频率为0.5、1、2、4、8周/度。
  • 使用两个预定义对比敏感度比值:弱视敏感度下降和分视敏感度下降。

临床怎么用

  • 在弱视评估中可考虑采用分视CSF补充标准单眼检查,以更好反映弱视眼视觉能力。
  • 分视CSF或可作为评估现代弱视治疗疗效的更可靠指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To study binocular balance by comparing dichoptic and standard monocular contrast sensitivity function (CSF) in stereonormal and stereoanomalous/stereoblind amblyopic subjects. METHODS: Sixteen amblyopes and 17 controls participated. Using the capability of the passive three-dimensional display, we measured their CSF both monocularly and dichoptically at spatial frequencies 0.5, 1, 2, 4, and 8 cpds using achromatic Gabor patches on a luminance noise background. During monocular stimulation, the untested eye was covered, while for the dichoptic stimulation the untested eye viewed background noise. Dichoptic CSF of both eyes was acquired within one block. RESULTS: In patients with central fixation, dichoptic viewing had a large negative impact on the CSF of the amblyopic eye, although it hardly affected that of the dominant eye. In contrast, dichoptic viewing had a small but significant effect on both eyes for controls. In addition, all participants lay along a continuum in terms of how much their two eyes were affected by dichoptic stimulation: by using two predefined contrast sensitivity ratios, namely, amblyopic sensitivity decrement and dichoptic sensitivity decrement, not only did we find a significant correlation between these variables among all participants, but also the two groups were identified with minimum error using a cluster analysis. CONCLUSIONS: Dichoptic CSF may be considered to measure visual performance in patients with altered binocular vision, because it better reflects the visual capacity of the amblyopic eye than the standard monocular examinations. It may also be a more reliable parameter to assess the efficacy of modern approaches to treat amblyopia.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Barboni MTS, Maneschg OA, Németh J, et al. Dichoptic Spatial Contrast Sensitivity Reflects Binocular Balance in Normal and Stereoanomalous Subjects. Invest Ophthalmol Vis Sci. 2020. PMID: 32931571. doi:10.1167/iovs.61.11.23

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。