儿童早期圆锥角膜的三维角膜形态几何与体积特征
该横断面研究纳入49眼儿童圆锥角膜(KC)和31眼健康对照,基于地形图原始数据构建三维角膜模型,评估形态几何与体积参数。早期和轻度KC组后顶点偏差及前后顶点差值高于对照组,总角膜体积降低;后顶点偏差、前后顶点差值和1.0-1.4mm直径间VOLMCTrel鉴别早期KC的AUROC均超过0.93。
要点
- 儿童早期和轻度KC的后顶点偏差及前后顶点差值高于正常对照。
- 儿童早期和轻度KC的总角膜体积较正常对照降低。
- 后顶点偏差、前后顶点差值和VOLMCTrel鉴别早期KC的AUROC均超过0.93。
核心结论
- 三维角膜模型可呈现儿童早期和轻度KC的形态几何与体积特征,相关参数有助于早期检出KC。
研究设计与样本
- 单中心横断面研究,纳入49例年龄≤16岁KC患者的49眼和31例健康儿童的31眼。
- KC眼按RETICS分类系统分为早期21眼和轻度28眼。
- 基于地形图原始数据生成三维角膜模型并评估形态几何与体积参数。
主要发现
- 早期和轻度KC组的Dapexpost及Dapexant-Dapexpost差值高于对照组(P < .05)。
- 早期和轻度KC组的Vtotal低于对照组(P < .05)。
- Dapexpost、Dapexant-Dapexpost差值和1.0-1.4mm直径间VOLMCTrel鉴别早期KC与正常的AUROC均超过0.93。
关键数值与推荐
- KC分级依据RETICS分类系统,分为早期(n = 21)和轻度(n = 28)。
- Dapexpost、Dapexant-Dapexpost差值和1.0-1.4mm直径间VOLMCTrel的AUROC均超过0.93。
临床怎么用
- 将形态几何与体积参数整合入地形图软件,可能为儿童KC早期检测提供额外价值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To present morphogeometric and volumetric characteristics of the cornea and its diagnostic value in pediatric patients with keratoconus (KC) using 3-dimensional (3-D) corneal modeling. DESIGN: Cross-sectional study. METHODS: This single-center (VISSUM Innovation, Alicante, Spain) study comprised 49 eyes of 49 pediatric patients (age ≤16 years) with KC and 31 eyes of 31 healthy pediatric controls. Eyes were graded as early (n = 21) and mild KC (n = 28) based on the RETICS (Thematic Network for Co-Operative Research in Health) classification system. The 3-D corneal model was generated using raw topographic data. Deviation of anterior (Dapexant) and posterior (Dapexpost) apex and minimum thickness points (Dmctant, Dmctpost), Dapexant-Dapexpost difference, total corneal volume (Vtotal), volumetric distribution (VOLAAP, VOLPAP, and VOLMCT), and percentage of relative volume increase (VOLAAPrel, VOLPAPrel, and VOLMCTrel) between 2 consecutive radii centered to anterior/posterior apex and thinnest point were evaluated. RESULTS: Dapexpost and Dapexant-Dapexpost difference were higher in the early and mild KC groups compared to the control group (P < .05). Eyes with early and mild KC had decreased Vtotal compared with the control group (P < .05). Dapexpost, Dapexant-Dapexpost difference, and VOLMCTrel between 1.0 and 1.4 mm diameters had area under receiver operating characteristics curve (AUROC) values over 0.93 in discrimination of early KC from normal. CONCLUSIONS: This is the first study presenting morphogeometric and volumetric characterization of cornea in pediatric patients with early and mild KC using a 3-D corneal model. Integration of the morphogeometric and volumetric parameters to topography software can add value in early detection of KC in pediatric patients.
引用
- Toprak I, Cavas F, Velázquez JS, et al. Three-Dimensional Morphogeometric and Volumetric Characterization of Cornea in Pediatric Patients With Early Keratoconus. Am J Ophthalmol. 2020. PMID: 32971022. doi:10.1016/j.ajo.2020.09.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。