一项前瞻性研究比较了飞秒LASIK与SMILE矫正近视后角膜瓣/帽厚度及基质光学密度(OD)的演变,随访3个月。结果显示两种术后角膜瓣/帽均显著增厚,SMILE组OD值在术后早期较高但随访期内显著下降,而LASIK组OD无显著变化。

要点

  • LASIK与SMILE术后3个月内中央角膜瓣/帽厚度均显著增加
  • SMILE术后角膜光学密度在3个月内显著降低,LASIK无显著变化
  • SMILE术后早期光学密度较高可能与视觉恢复延迟相关

核心结论

  • LASIK角膜瓣和SMILE角膜帽术后均出现显著再增厚。
  • SMILE角膜在术后早期光学密度高于LASIK,但随后显著下降至3个月。
  • 这些发现与SMILE术后视觉恢复延迟相关。

研究设计与样本

  • 前瞻性研究,纳入78眼(每组39眼),比较飞秒LASIK(Visumax)与SMILE矫正近视。
  • 术后1天、1周、1个月和3个月使用眼前节OCT(MS39)测量瓣/帽厚度。
  • 使用ImageJ软件在三个区域测量光学密度(灰度单位):瓣/帽基质、残余基质床和全部基质。

主要发现

  • LASIK组中央厚度平均增加5.43±4.23 μm(p=0.0118),SMILE组增加2.76±5.61 μm(p=0.0118),组间差异有统计学意义(p=0.020)。
  • SMILE组光学密度从术后1天到3个月显著下降:帽48.96±5.55 vs 44.95±5.41(p=0.19×10-6),残余基质床50.26±7.06 vs 45.42±7.53(p=0.00005),全部基质50.34±6.49 vs 45.46±6.96(p=0.5×10-5)。
  • LASIK组光学密度在随访期间无统计学显著变化。
  • 两种技术间各时间点光学密度值无显著差异,但SMILE在术后第一个月内呈现较高趋势。
  • Visumax制瓣/帽厚度与目标值比较:帽偏厚趋势11.48±7.85 μm,瓣2.73±8.93 μm(p=0.00003)。

临床怎么用

  • 术后早期SMILE角膜光学密度较高,解释视觉恢复延迟的可能机制。
  • 随访中需关注角膜瓣/帽厚度变化,尤其SMILE术后早期。
  • 光学密度测量可作为评估角膜愈合反应的辅助指标。

局限性

  • 样本量有限(78眼),随访仅3个月。
  • 未报告视觉 acuity 等功能指标与光学密度的直接相关性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the thickness and stromal optical density (OD) evolution of the flap and cap after femtosecond (FS-LASIK; Visumax) and small incision lenticule extraction (SMILE), respectively, for myopia correction. METHODS: A prospective study comprising 78 eyes (n=39 per group) was performed. Anterior segment optical coherence tomography (MS39) images were collected at each postoperative visit (1 day, 1 week and 1 and 3 months) and flap/cap thicknesses were measured. Using ImageJ software, three regions were defined to measure OD (in grayscale units: flap/cap stroma, residual stromal bed (RSB) and all stroma (including flap/cap-stroma, surgical interface and RSB). RESULTS: Mean central thickness significantly increased during the 3-month follow-up in both LASIK (5.43±4.23 μm; p=0.0118) and SMILE (2.76±5.61 μm; p=0.0118), with differences between both techniques statistically significant (p=0.020). All OD values showed a statistically significant reduction during SMILE follow-up: cap 48.96±5.55 versus 44.95±5.41 (p=0.19×10-6), RSB 50.26±7.06 versus 45.42±7.53 (p=0.00005), total stroma 50.34±6.49 versus 45.46±6.96 (p=0.5×10-5) at 1 day and 3 months, respectively, whereas no statistically significant changes were found during LASIK follow-up. No significant differences were observed in OD values between both techniques at any time point, although SMILE showed a tendency for higher OD values than LASIK within the first postoperative month. Visumax presented a tendency for thicker caps than target (11.48±7.85 μm), but not for flaps (2.73±8.93 μm) (p=0.00003). CONCLUSIONS: Both LASIK flaps and SMILE caps show a significant postoperative rethickening. SMILE corneas present higher optical densities than LASIK corneas in the early postoperative period, with a significant decrease thereafter and up to 3 months. These findings correlate with the delayed visual recovery observed after SMILE.