虹膜配准囊口标记与手动标记在白内障手术散光矫正型人工晶状体对位中的比较
一项前瞻性队列研究纳入57例需白内障手术并植入散光矫正型人工晶状体(Acrysof SN6AT3-T8)的患者,分为飞秒激光辅助囊口标记(CM)组26眼与常规裂隙灯辅助手动标记(MM)组31眼。术后1个月和3个月测量显示,CM组未矫正远视力、残余散光和人工晶状体对位误差均显著低于MM组,而最佳矫正远视力和调制传递函数面积比无显著组间差异。结论为CM组轴向对位准确性更高,带来更低的残余散光和更好的视觉结局。
要点
- CM组术后未矫正远视力(logMAR)显著优于MM组(P < .05)。
- CM组残余散光和人工晶状体对位误差均显著低于MM组(均P < .05)。
- 最佳矫正远视力和调制传递函数面积比两组无显著差异(均P > .05)。
核心结论
- CM组轴向对位准确性显著更高,导致更低的残余散光和更好的视觉结局。
研究设计与样本
- 前瞻性队列研究,共57例需白内障手术并植入散光矫正型人工晶状体(Acrysof SN6AT3-T8)的患者,CM组26眼,MM组31眼。
主要发现
- 术后未矫正远视力(logMAR)CM组显著低于MM组(P < .05)。
- 术后残余散光和人工晶状体对位误差CM组均显著低于MM组(均P < .05)。
- 最佳矫正远视力和调制传递函数面积比两组无显著差异(均P > .05)。
- 未矫正远视力(logMAR)与残余散光(r = 0.339;P < .05)和人工晶状体对位误差(r = 0.317;P < .05)正相关,与调制传递函数面积比负相关(r = -0.272;P < .05);残余散光与人工晶状体对位误差正相关(r = 0.405;P < .05)。
临床怎么用
- 对于需植入散光矫正型人工晶状体的白内障患者,采用飞秒激光辅助囊口标记可能提高轴向对位准确性并减少残余散光。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the accuracy of toric intraocular lens (IOL) alignment and visual outcomes using femtosecond laser-assisted capsulotomy marking (CM) versus conventional slit lamp-assisted manual marking (MM). DESIGN: Prospective cohort study. METHODS: A total of 57 patients who required cataract surgery and toric IOL implantation (Acrysof SN6AT3-T8) were assigned to the CM group (26 eyes) or the MM group (31 eyes). Uncorrected distant visual acuity (UCDVA), best-corrected distant visual acuity (BCDVA), residual astigmatism (RA), IOL misalignment, and modulation transfer function (area ratio [AR] value) were measured 1 and 3 months after surgery. RESULTS: Postoperative UCDVA (logarithm of minimal angle of resolution [logMAR]) was significantly lower in the CM group than that in the MM group (P < .05). Postoperative RA and IOL misalignment were significantly lower in the CM group than that in the MM group (both P < .05). No significant difference between the groups was observed for BCDVA or AR value (both P > .05). UCDVA (logMAR) was positively correlated with RA (r = 0.339; P < .05) and IOL misalignment (r = 0.317; P < .05) and negatively correlated with the the AR value (r = -0.272; P < .05); RA was positively correlated with IOL misalignment (r = 0.405; P < .05). CONCLUSIONS: The accuracy of the axis alignment was significantly higher in the CM group, which resulted in lower residual astigmatism and better visual outcomes.
引用
- Chen Q, Zhang G. Iris Registration Capsulotomy Marking Versus Manual Marking for Toric Intraocular Lens Alignment in Cataract Surgery. Am J Ophthalmol. 2020. PMID: 32890470. doi:10.1016/j.ajo.2020.08.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。