人工晶状体特征对白内障术后脱位的影响
该回顾性队列纳入1996至2017年奥地利Graz眼科68 199只眼,评估IOL特征与术后囊袋内(ITB)及囊袋外(OTB)脱位的关联。亲水性、四襻及襻成角IOL与ITB脱位风险升高相关,三片式及更大整体直径与风险降低相关;硅胶IOL与OTB脱位高风险相关。
要点
- 亲水性IOL、四襻IOL及襻成角与囊袋内脱位风险升高独立相关。
- 三片式IOL及更大整体直径与囊袋内脱位风险降低相关。
- 硅胶IOL与囊袋外脱位高风险相关,更大整体直径与风险降低相关。
核心结论
- 亲水性IOL、四襻IOL及襻成角与ITB脱位风险升高相关,三片式IOL和更大整体直径与风险降低相关。
- OTB脱位的危险因素为硅胶IOL、亲水性IOL及更小整体IOL直径。
研究设计与样本
- 回顾性队列研究,纳入1996至2017年奥地利Graz眼科白内障手术患者并复习病历。
- 共68 199只眼(46 632例患者,女性60.2%,平均年龄73.71±10.82岁)。
- 采用Cox比例风险回归模型评估IOL特征对IOL脱位的影响,并校正易感因素。
主要发现
- ITB脱位111只眼(0.16%),OTB脱位35只眼(0.05%)。
- ITB脱位校正后HR:亲水性IOL 2.35(95%CI 1.45–3.8),四襻IOL 2.01(95%CI 1.04–3.86),襻成角1.61(95%CI 1.04–2.48)。
- ITB脱位风险降低:三片式IOL HR 0.58(95%CI 0.34–0.98),更大整体直径HR 0.79(95%CI 0.66–0.95)。
- OTB脱位风险升高:硅胶IOL HR 18.81(95%CI 5.84–60.58),亲水性IOL HR 2.12(95%CI 0.62–7.29)。
- OTB脱位风险降低:更大整体直径HR 0.40(95%CI 0.25–0.63)。
临床怎么用
- 选择IOL时可参考特征风险:亲水性、四襻、襻成角及硅胶材料与脱位风险相关。
- 三片式设计及更大整体直径与囊袋内脱位风险降低相关,可作为IOL选择考量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To assess the influence of intraocular lens (IOL) characteristics on IOL dislocations after cataract surgery. METHODS: Patients who underwent cataract surgery at the Department of Ophthalmology Graz, Austria, between 1996 and 2017 were included and medical records were reviewed. Cox proportional-hazard regression models were used to assess the influence of IOL characteristics on IOL dislocation. RESULTS: From 68 199 eyes out of 46 632 patients (60.2% women, mean age: 73.71 SD±10.82 years), 111 (0.16%) had an in-the-bag (ITB) disloaction and 35 (0.05%) had an out-of-the-bag (OTB) dislocation. The HRs adjusted for predisposing factors significantly associated with a higher risk for an ITB dislocation were 2.35 (95% CI, 1.45 to 3.8) for hydrophilic IOLs, 2.01 for quadripode IOLs (95% CI, 1.04 to 3.86) and 1.61 (95% CI, 1.04 to 2.48) for haptic angulation. A lower risk was observed for three-piece IOLs (HR=0.58, 95% CI, 0.34 to 0.98) and larger overall IOL diameter (HR=0.79, 95% CI, 0.66 to 0.95). For an OTB dislocation, the HR associated with a higher risk was 18.81 (95% CI, 5.84 to 60.58) for silicone IOLs and 2.12 (95% CI, 0.62 to 7.29) for hydrophilic IOLs. Larger overall IOL diameter (HR 0.40, 95% CI; 0.25 to 0.63) showed a lower risk. CONCLUSION: Hydrophilic IOLs, quadripode IOLs and haptic angulation were associated with a higher risk for an ITB dislocation, whereas three-piece IOLs and a larger overall diameter were associated with a lower risk. Risk factors for OTB dislocation were silicone IOLs, hydrophilic IOLs and a smaller overall IOL diameter.
引用
- Mayer-Xanthaki CF, Pregartner G, Hirnschall N, et al. Impact of intraocular lens characteristics on intraocular lens dislocation after cataract surgery. Br J Ophthalmol. 2020. PMID: 32950959. doi:10.1136/bjophthalmol-2020-317124
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。