文献速递角膜与眼表疾病白内障与屈光手术

角膜滴状赘疣与核性白内障对对比敏感度的影响

Influence of corneal guttae and nuclear cataract on contrast sensitivity.
PubMed 文献 · Br J Ophthalmol · 2020-09-09

回顾性单中心病例系列纳入50眼,比较合并角膜滴状赘疣的核性白内障(研究组,行三联DMEK)与无滴状赘疣的核性白内障(对照组,行白内障手术)的对比敏感度。术前研究组MARS字母和OPTEC 6500P对比敏感度显著更差;术后MARS字母对比敏感度组间无显著差异,但OPTEC 6500P在多数空间频率仍显著更低。结论认为角膜滴状赘疣会额外降低核性白内障眼的对比敏感度,支持即使视力≥20/40也行三联DMEK。

要点

  • 角膜滴状赘疣会额外降低核性白内障眼的对比敏感度。
  • 术后MARS字母对比敏感度组间无显著差异(p=0.225)。
  • 术后OPTEC 6500P在多数空间频率仍显著更低(p<0.01)。

核心结论

  • 角膜滴状赘疣使核性白内障眼对比敏感度额外显著下降。
  • 该结果支持即使视力≥20/40也行三联DMEK。

研究设计与样本

  • 回顾性单中心病例系列,纳入50眼(50例)。
  • 研究组25眼为角膜滴状赘疣合并核性白内障,行三联DMEK。
  • 对照组25眼为核性白内障且角膜健康,行白内障手术。
  • 纳入标准为术前最佳矫正视力≥20/40、无角膜水肿、晶状体混浊程度相似(核混浊2.0-2.9)。
  • 结局指标包括MARS字母和OPTEC 6500P对比敏感度测试、角膜体积、中央角膜厚度及前后角膜密度测量。

主要发现

  • 术前研究组MARS字母对比敏感度显著更差(p<0.001)。
  • 术前研究组OPTEC 6500P在日光下伴或不伴眩光及夜光下无眩光的低空间频率显著更差(p<0.007)。
  • 术后MARS字母对比敏感度组间无显著差异(p=0.225)。
  • 术后研究组OPTEC 6500P在日光和夜光下伴或不伴眩光的多数空间频率仍显著更低(p<0.01)。
  • 术前和术后角膜体积、中央角膜厚度及前角膜密度测量两组相等(p>0.05)。

关键数值与推荐

  • 术前最佳矫正视力≥20/40。
  • 无角膜水肿。
  • 核混浊程度2.0-2.9。

临床怎么用

  • 对核性白内障合并角膜滴状赘疣者应评估对比敏感度而非仅视力。
  • 即使视力≥20/40,角膜滴状赘疣导致的对比敏感度下降可支持三联DMEK决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To evaluate the contrast sensitivity in patients with nuclear cataract and corneal guttae compared to patients with nuclear cataract without guttae. METHODS: In this retrospective, single-centre case series, 50 eyes of 50 patients fulfilling the inclusion criteria were enrolled. Patients with corneal guttae and nuclear cataract (n=25, study group) underwent triple Descemet membrane endothelial keratoplasty (DMEK). Patients with nuclear cataract and healthy corneas underwent cataract surgery (n=25, control group). Inclusion criteria were preoperative best-corrected visual acuity ≥20/40, no corneal oedema and similar lens opacity (nuclear opalescence 2.0-2.9). Outcome measures included MARS letter and OPTEC 6500P contrast sensitivity test, corneal volume, central corneal thickness and anterior and posterior corneal densitometry. RESULTS: Preoperative MARS letter and OPTEC 6500P contrast sensitivity was significantly worse in the study group (MARS: p<0.001; OPTEC 6500P: p<0.007 at low spatial frequencies in daylight with and without glare and nightlight without glare). After surgery, there was no significant difference in MARS letter contrast sensitivity between groups (p=0.225). OPTEC 6500P contrast sensitivity remained significantly lower in the study group in daylight and nightlight with and without glare at most spatial frequencies (p<0.01) postoperatively. Preoperative and postoperative corneal volume, central corneal thickness and anterior corneal densitometry were equal in both groups (p>0.05). Posterior densitometry was significantly higher in the study group than in the control group preoperatively (p<0.001) but turned into equal values postoperatively (p=0.07). CONCLUSIONS: Corneal guttae cause an additional significant decrease in contrast sensitivity in eyes with nuclear cataract. This is in favour of performing a triple DMEK even in eyes with a visual acuity of ≥20/40.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Augustin VA, Weller JM, Kruse FE, et al. Influence of corneal guttae and nuclear cataract on contrast sensitivity. Br J Ophthalmol. 2020. PMID: 32907813. doi:10.1136/bjophthalmol-2019-315206

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。