文献速递眼底病与葡萄膜炎

穹顶状黄斑高度近视眼伴或不伴未治疗浆液性视网膜脱离的4年自然病程

Long-term natural history of highly myopic eyes with a dome-shaped macula with or without untreated serous retinal detachment: a 4-year follow-up study.
PubMed 文献 · Br J Ophthalmol · 2020-09-05

结果显示未治疗情况下最佳矫正视力在48个月内保持临床稳定,浆液性视网膜脱离虽持续存在并波动但未显著影响视力,基线最佳矫正视力是最终视力的唯一显著影响因素。

要点

  • 伴穹顶状黄斑的高度近视眼在4年随访中最佳矫正视力保持临床稳定。
  • 未治疗的浆液性视网膜脱离可波动和持续存在,但不显著影响视力。
  • 基线最佳矫正视力是最终视力的唯一显著影响因素。

核心结论

  • 伴穹顶状黄斑的高度近视眼在未治疗情况下最佳矫正视力在4年内保持临床稳定,尽管浆液性视网膜脱离存在波动和持续。
  • 基线最佳矫正视力是分析参数中唯一对最终最佳矫正视力有显著影响的参数。

研究设计与样本

  • 前瞻性单中心研究,纳入连续的高度近视伴穹顶状黄斑患者,伴或不伴浆液性视网膜脱离。
  • 随访最长间隔6个月,持续4年,排除脉络膜新生血管眼。

主要发现

  • 随访48个月期间,伴与不伴浆液性视网膜脱离眼的最佳矫正视力无显著差异。
  • 多变量分析显示基线最佳矫正视力对最终最佳矫正视力有显著影响(p<0.0001)。
  • 浆液性视网膜脱离随时间波动,其高度显著受脉络膜厚度影响(p=0.002)。
  • 巩膜隆起厚度对浆液性视网膜脱离厚度无影响。

关键数值与推荐

  • 穹顶状黄斑形态为水平型占69%、圆型占31%。

临床怎么用

  • 对于伴穹顶状黄斑的高度近视眼合并浆液性视网膜脱离,可考虑观察随访而不急于干预。
  • 基线最佳矫正视力可作为预测最终视力的重要参考指标。

局限性

  • 单中心研究设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the long-term functional and morphological changes occurring in myopic eyes with a dome-shaped macula (DSM), with or without untreated serous retinal detachment (SRD). METHODS: This prospective, single-centre study enrolled consecutive cases of highly myopic patients with DSM with or without a SRD. Patients underwent complete ophthalmological examinations, optical coherence tomography, axial length measurements and autofluorescence. Follow-up visits were performed with a maximum interval of 6 months for 4 years. Eyes with choroidal neovascularisation were excluded. RESULTS: Twenty-six eyes from 18 patients (mean age 61.2) were included. At baseline, 13 eyes had SRD and 13 did not. The DSMs were either horizontal (69%) or round (31%). There were no significant differences in best-corrected visual acuity (BCVA) between eyes with and without SRD during the 48-month follow-up period. Multivariate analysis showed that baseline BCVA was the only parameter among those analysed (age and SRD height) to have a significant effect on the final BCVA (p<0.0001). SRD fluctuated overtime and SRD height was significantly influenced by choroidal thickness (p=0.002). The scleral bulge thickness had no effect on SRD thickness. CONCLUSIONS: BCVA remained clinically stable over 4 years without treatment despite the fluctuations and persistence of the SRDs.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Viola F, Leone G, Garoli E, et al. Long-term natural history of highly myopic eyes with a dome-shaped macula with or without untreated serous retinal detachment: a 4-year follow-up study. Br J Ophthalmol. 2020. PMID: 32892162. doi:10.1136/bjophthalmol-2020-316629

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。