文献速递眼底病与葡萄膜炎小儿眼科与斜弱视

计算相关眼数据的敏感性、特异性与预测值

Calculating Sensitivity, Specificity, and Predictive Values for Correlated Eye Data.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2020-01-01

该研究描述并演示了针对相关眼数据估计敏感性、特异性、预测值及其95%置信区间的适当统计方法。通过早产儿视网膜病变远程医疗临床研究数据,比较了广义估计方程(GEE)和聚类自举法与忽略眼间相关性的朴素方法。结论是当双眼均接受检测时,应在眼水平分析并考虑眼间相关性,忽略相关性会导致95%CI不恰当地变窄。

要点

  • 双眼数据存在眼间相关性,统计分析应在眼水平进行。
  • GEE或聚类自举法可适当处理眼间相关性。
  • 忽略眼间相关性会使95%CI不恰当地变窄。

核心结论

  • 当部分或全部研究对象的双眼均进行眼部检测时,统计分析最好在眼水平进行,并使用GEE或聚类自举法考虑眼间相关性。
  • 忽略眼间相关性会导致95%CI不恰当地变窄,而分别分析左右眼数据效率不高。

研究设计与样本

  • 方法学研究,描述并演示GEE和聚类自举法处理眼间相关性。
  • 应用上述方法分析一项早产儿视网膜病变远程医疗检测的临床研究数据,纳入100名婴儿(200只眼)。

主要发现

  • 100名婴儿中,20名双眼均有需转诊的早产儿视网膜病变(RW-ROP),9名单眼有RW-ROP。
  • 在纳入双眼的每眼分析中,图像评估RW-ROP的敏感性为83.7%,特异性为86.8%。
  • 忽略眼间相关性的朴素方法得到的95%CI宽度窄于GEE和聚类自举法:敏感性95%CI宽度分别为22.4%、23.2%、23.9%;特异性分别为11.4%、12.5%、11.6%。
  • 分别从左眼和右眼计算的敏感性和特异性95%CI更宽:敏感性95%CI宽度分别为35.2%和30.8%,特异性分别为25.4%和17.3%。

临床怎么用

  • 在双眼均接受检测的眼科研究中,应采用GEE或聚类自举法在眼水平分析数据,以正确估计敏感性、特异性、预测值及其95%CI。
  • 避免忽略眼间相关性或分别分析双眼,以防止置信区间不恰当地变窄或效率损失。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To describe and demonstrate appropriate statistical approaches for estimating sensitivity, specificity, predictive values and their 95% confidence intervals (95% CI) for correlated eye data. METHODS: We described generalized estimating equations (GEE) and cluster bootstrap to account for inter-eye correlation and applied them for analyzing the data from a clinical study of telemedicine for the detection of retinopathy of prematurity (ROP). RESULTS: Among 100 infants (200 eyes) selected for analysis, 20 infants had referral-warranted ROP (RW-ROP) in both eyes and 9 infants with RW-ROP only in one eye based on clinical eye examination. In the per-eye analysis that included both eyes of an infant, the image evaluation for RW-ROP had sensitivity of 83.7% and specificity of 86.8%. The 95% CI's from the naïve approach that ignored the inter-eye correlation were narrower than those of the GEE approach and cluster bootstrap for both sensitivity (width of 95% CI: 22.4% vs. 23.2% vs. 23.9%) and specificity (11.4% vs. 12.5% vs. 11.6%). The 95% CIs for sensitivity and specificity calculated from left eyes and right eyes separately were wider (35.2% and 30.8% respectively for sensitivity, 25.4% and 17.3% respectively for specificity). CONCLUSIONS: When an ocular test is performed in both eyes of some or all of the study subjects, the statistical analyses are best performed at the eye-level and account for the inter-eye correlation by using either the GEE or cluster bootstrap. Ignoring the inter-eye correlation results in 95% CIs that are inappropriately narrow and analyzing data from two eyes separately are not efficient.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Ying GS, Maguire MG, Glynn RJ, et al. Calculating Sensitivity, Specificity, and Predictive Values for Correlated Eye Data. Invest Ophthalmol Vis Sci. 2020. PMID: 32936302. doi:10.1167/iovs.61.11.29

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。