文献速递角膜与眼表疾病

基于Scheimpflug成像的圆锥角膜患病率:Raine研究

Prevalence of Keratoconus Based on Scheimpflug Imaging: The Raine Study.
PubMed 文献 · Ophthalmology · 2020-08-26

这项横断面研究纳入澳大利亚珀斯1259名20岁年轻人,用Pentacam Scheimpflug成像以Belin/Ambrósio增强扩张显示评分≥2.6定义圆锥角膜,患病率为1.2%(95%CI 0.7%-1.9%),即1/84,为全球报道最高之一。圆锥角膜与规律吸烟相关,与性别、种族、BMI、戴镜史、过敏性眼病史及妊娠无关联。

要点

  • 20岁人群圆锥角膜患病率为1.2%(95%CI 0.7%-1.9%),约1/84。
  • 患者最佳矫正视力、柱镜、等效球镜、陡峭轴平均角膜曲率及最薄点角膜厚度均显著差于非患者。
  • 圆锥角膜与规律吸烟相关(38.5% vs 14.6%,P=0.04),提示可在更年轻时筛查。

核心结论

  • 澳大利亚20岁人群圆锥角膜患病率为1.2%(95%CI 0.7%-1.9%),即1/84,为全球报道最高之一。

研究设计与样本

  • 横断面研究,纳入Raine研究出生队列20年随访的1259名20岁参与者,行Pentacam Scheimpflug成像及健康问卷。

主要发现

  • 圆锥角膜组与非圆锥角膜组最佳矫正视力为0.01 logMAR vs -0.05 logMAR(P=0.007)。
  • 两组柱镜为1.25 D vs 0.25 D(P<0.001),等效球镜为-1.42 D vs -0.50 D(P=0.02)。
  • 两组陡峭轴平均角膜曲率为45.19 D vs 43.76 D(P<0.001),最薄点平均角膜厚度为475 μm vs 536 μm(P<0.001)。
  • 圆锥角膜与规律吸烟相关(38.5% vs 14.6%,P=0.04),与性别、种族、BMI、戴镜史、过敏性眼病史及妊娠无关联。

关键数值与推荐

  • 圆锥角膜定义为任一眼Pentacam Belin/Ambrósio增强扩张显示评分≥2.6。

临床怎么用

  • 在20岁左右人群可考虑用Scheimpflug成像筛查圆锥角膜,以便在疾病进展前启动治疗。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To describe the prevalence and systemic associations of keratoconus in young adults in Perth, Western Australia. DESIGN: Cross-sectional study. PARTICIPANTS: One thousand two hundred fifty-nine participants 20 years of age. METHODS: The Raine Study is a multigenerational, longitudinal cohort study based in Perth, Western Australia. This study represents a cross-sectional analysis of the birth cohort on returning for a 20-year follow-up. Participants underwent a detailed ophthalmic examination, including visual acuity assessment and Scheimpflug imaging using the Pentacam (Oculus, Wetzlar, Germany), and completed a health questionnaire. Keratoconus was defined as a Belin/Ambrόsio enhanced ectasia display score of 2.6 or more in either eye based on Pentacam imaging. MAIN OUTCOME MEASURES: Prevalence of keratoconus in this cohort. RESULTS: Of the 1259 participants, 50.8% were women and 85.7% were White. Fifteen participants had keratoconus in at least 1 eye, giving a prevalence of 1.2% (95% confidence interval, 0.7%-1.9%), or 1 in 84. A significant difference was found in best-corrected visual acuity (0.01 logarithm of the minimum angle of resolution vs. -0.05 logarithm of the minimum angle of resolution; P = 0.007), cylinder (1.25 diopters [D] vs. 0.25 D cylinder; P < 0.001) and spherical equivalent (-1.42 D vs. -0.50 D sphere; P = 0.02) on objective refraction, mean keratometry of the steep meridian (45.19 D vs. 43.76 D; P < 0.001), and mean corneal thickness at the thinnest point (475 μm vs. 536 μm; P < 0.001) between those with and without keratoconus. Keratoconus was associated with regular cigarette smoking (38.5% vs. 14.6%; P = 0.04), but showed no association with gender, race, body mass index, use of spectacles or contact lenses, history of allergic eye disease, or pregnancy. CONCLUSIONS: The prevalence of keratoconus in this Australian population-based study of 20-year-old adults was 1.2% (95% confidence interval, 0.7%-1.9%), or 1 in 84, which is one of the highest reported in the world. This has important implications for screening individuals at a younger age so that treatment can be initiated before disease progression.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Chan E, Chong EW, Lingham G, et al. Prevalence of Keratoconus Based on Scheimpflug Imaging: The Raine Study. Ophthalmology. 2020. PMID: 32860813. doi:10.1016/j.ophtha.2020.08.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。