文献速递白内障与屈光手术角膜与眼表疾病

人工泪液对白内障患者角膜曲率测量的影响

Influence of Artificial Tears on Keratometric Measurements in Cataract Patients.
PubMed 文献 · Am J Ophthalmol · 2020-08-21

这项前瞻性随机交叉研究纳入80例患者123只眼,评估不同黏度人工泪液对白内障术前角膜曲率读数的影响。结果显示滴眼液后测量变异性显著增加(P < .01),干眼组更明显,高黏度滴眼液影响更强更持久,建议滴眼后等待超过5分钟再测量。

要点

  • 人工泪液会显著增加角膜曲率测量变异性,干眼患者更明显。
  • 高黏度滴眼液对角膜曲率的影响更强且持续时间更长。
  • 建议滴眼后等待超过5分钟再进行角膜曲率测量。

核心结论

  • 角膜曲率测量前使用稳定泪膜的人工泪液会显著影响K读数,尤其在干眼眼中。
  • 滴眼液黏度越高,对角膜曲率测量的影响越强且持续时间越长。

研究设计与样本

  • 前瞻性随机交叉、前后对照临床研究,设置于维也纳医科大学眼科。
  • 共纳入80例患者123只眼,按正常眼和干眼分为2组。

主要发现

  • 正常眼和干眼组基线测量重复性高,标准差均为0.02 mm。
  • 滴入低黏度或高黏度滴眼液后,正常眼和干眼组的测量变异性均显著增加(P < .01)。
  • 测量变异性在基线测量与30秒之间最为明显,并随时间推移而减弱。
  • 干眼组的K读数变异性高于正常眼组。
  • 使用高黏度滴眼液时,散光变化超过0.5屈光度的比例在正常眼为13.2%,在干眼为34.4%。

临床怎么用

  • 白内障术前角膜曲率测量前应避免使用人工泪液,或滴眼后等待超过5分钟再测量。
  • 对干眼患者及使用高黏度滴眼液者,应延长等待时间以减少测量误差。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the influence of artificial tears of different viscosity on K-readings prior to cataract surgery. DESIGN: Prospective randomized crossover, before-and-after clinical study. METHODS: Setting: Department of Ophthalmology, Medical University of Vienna. PATIENT POPULATION: A total of 123 eyes of 80 patients prior to cataract surgery were assigned to 2 groups based on normal and dry eyes. INTERVENTION: Two native baseline keratometries were followed by instillation of either high- or low-viscosity eye drops. Keratometry was repeated 30 seconds, 2 minutes, and 5 minutes after instillation. MAIN OUTCOME MEASURES: Influence of eye drops of different viscosity in normal and dry eyes on short time K-readings. RESULTS: Repeatability between native baseline measurements was high (standard deviation = 0.02 mm in normal and in dry eyes). In normal and dry eyes, a statistically significant increase in measurement variability after instillation of both low-viscosity and high-viscosity eye drops was observed (P < .01). Measurement variability was most pronounced between baseline measurement and 30 seconds and diminished over time. Variability of K-readings appeared higher in dry eyes compared with normal eyes. Astigmatism changed more than 0.5 diopters in 13.2% of normal eyes and 34.4% in dry eyes using eye drops of high viscosity. CONCLUSION: Tear film-stabilizing eye drops prior to keratometry measurements influenced K-readings significantly, especially in dry eyes. A time period of more than 5 minutes should be allowed to pass after instillation of eye drops. The higher the viscosity of the eye drops, the stronger the influence and the longer its persistence.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Röggla V, Leydolt C, Schartmüller D, et al. Influence of Artificial Tears on Keratometric Measurements in Cataract Patients. Am J Ophthalmol. 2020. PMID: 32828877. doi:10.1016/j.ajo.2020.08.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。