OCT视网膜神经纤维层与黄斑扫描伪影对青光眼进展检测的影响
在存在伪影的扫描中,23.9%掩盖了真实进展(假阴性),36.5%导致假性进展判断(假阳性),39.6%不影响进展判读。结论强调必须仔细检查原始B扫描以识别伪影和真实青光眼进展。
要点
- 有伪影扫描中23.9%掩盖真实进展,36.5%导致假性进展。
- 仅依赖自动分割变化图判读进展不可靠,需查看原始B扫描。
核心结论
- SDOCT视网膜神经纤维层和黄斑扫描中伪影高度常见,可导致青光眼进展判读的假阳性和假阴性。
- 仔细检查视网膜神经纤维层和黄斑的原始B扫描图像对于识别伪影和真实青光眼进展至关重要。
研究设计与样本
- 回顾性可靠性分析,纳入一个月内接受SDOCT成像的青光眼和可疑青光眼患眼。
- 所有病例至少有4组间隔6个月的视网膜神经纤维层和黄斑图像。
- 共纳入190只眼、760组OCT视网膜神经纤维层和黄斑扫描。
主要发现
- 视网膜前膜和玻璃体黄斑牵拉是最常见的伪影。
- 总体真实进展见于39.5%(75/190)的扫描。
- 有伪影的扫描中,23.9%(23/96)掩盖真实进展(假阴性),36.5%(35/96)导致假性进展判断(假阳性),39.6%(38/96)不影响进展判读。
- 视网膜神经纤维层扫描真实进展与黄斑扫描真实进展显著相关(P < .001);视网膜神经纤维层伪影与黄斑伪影也显著相关(P < .001)。
临床怎么用
- 在青光眼门诊解读SDOCT进展时,不能仅依赖自动分割变化图,应仔细检查视网膜神经纤维层和黄斑的原始B扫描以识别伪影。
- 对于重度青光眼、高血压及高龄患者,应警惕视网膜神经纤维层伪影可能影响进展判读。
局限性
- 原文未报告研究局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine the prevalence of artifacts on segmented spectral-domain optical coherence tomography (SDOCT) images and assess their impact on the interpretation of glaucomatous progression in the retinal nerve fiber layer (RNFL) profile and macular thickness map. DESIGN: Retrospective reliability analysis. METHODS: Retrospective review of glaucoma and glaucoma suspect eyes imaged with SDOCT during a 1-month period. All cases had at least 4 sets of RNFL and macular images at 6-month intervals. SDOCT raw B-scans were examined to determine true progression and whether artifacts impacted the original interpretation of progression based on auto-segmented change maps. The co-prevalence of artifacts in the RNFL and macula was assessed, as well as the association of clinical factors with the likelihood of artifacts. RESULTS: A total of 190 eyes with 760 sets of OCT RNFL and macular scans were included. Fifty percent (96/190) of eyes had artifacts, either in the circumpapillary RNFL (83/190; 43.68%) or the macula (57/190; 30.0%). Epiretinal membrane and vitreomacular traction were the most common artifacts. True progression was present on 39.5% (75/190) of scans overall. Among scans with artifacts, 23.9% (23/96) of artifacts masked true progression (ie, false-negative), 36.5% (35/96) led to an interpretation of false progression (ie, false-positive), and 39.6% (38/96) had no effect on the interpretation of progression. The presence of true progression on the RNFL scan was significantly associated with the presence of true progression on the macular scan (P < .001). Similarly, the presence of artifacts on the RNFL scan was significantly associated with artifacts on the macular scan (P < .001). In multivariable analysis, severe glaucoma, hypertension, and age were significantly associated with the presence of artifacts on RNFL (P < .05). CONCLUSIONS: Artifacts are highly prevalent on both circumpapillary RNFL and macular scans on SDOCT images acquired in a glaucoma clinic. Artifacts can lead to false-positive and false-negative interpretation of progression when using only the auto-segmentation change maps. Thus, careful examination of the raw B-scan images of both the RNFL and macula is critical to identify artifacts and true glaucoma progression.
引用
- Li A, Thompson AC, Asrani S, et al. Impact of Artifacts From Optical Coherence Tomography Retinal Nerve Fiber Layer and Macula Scans on Detection of Glaucoma Progression. Am J Ophthalmol. 2020. PMID: 32818450. doi:10.1016/j.ajo.2020.08.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。