新型24-2指标检测早期中心性青光眼损害的评价
该横断面研究纳入70只青光眼眼和45只健康眼,比较基于24-2视野中心12点的PSD(C24-2)与10-2视野PSD(10-2)检测中心性损害的能力。结果显示两者显著相关,但均漏诊大量经客观结构-功能参考标准确认的中心性损害,PSD(C24-2)漏诊61%,PSD(10-2)漏诊52%。结论认为两者均非早期中心性损害的良好指标,推荐基于OCT概率图与10-2视野的地形图方法。
要点
- PSD(C24-2)与PSD(10-2)显著相关,但识别异常眼数无显著差异。
- 以CD-RS为标准,PSD(C24-2)漏诊61%的中心性损害眼,PSD(10-2)漏诊52%。
- 推荐采用基于OCT概率图与10-2视野的地形图方法评估早期中心性损害。
核心结论
- PSD(C24-2)和PSD(10-2)均不能良好检测早期中心性青光眼损害。
- 推荐采用基于OCT概率图和10-2视野的地形图方法。
研究设计与样本
- 横断面研究,纳入青光眼组70眼/患者(24-2 MD优于-6 dB)和健康组45眼/患者。
- 所有受试者在4周内完成两次24-2和10-2视野及OCT扫描。
- PSD(C24-2)基于24-2视野中心12个点计算,并与PSD(10-2)比较。
- 事后分析结合中心性损害参考标准(CD-RS),基于10-2视野异常点与OCT概率图的地形图比较。
主要发现
- 115个PSD(C24-2)与PSD(10-2)值显著相关(Spearman相关系数rho=0.55,P<.001)。
- PSD(C24-2)识别19只异常青光眼眼,PSD(10-2)识别22只,两者无显著差异(P=.15)。
- 基于CD-RS,70只青光眼眼中44只被分类为异常。
- PSD(C24-2)漏诊44只中的27只(61%),PSD(10-2)漏诊23只(52%)。
- 事后分析显示这些漏诊眼多数存在明确的中心性损害。
临床怎么用
- 不应单独依赖PSD(C24-2)或PSD(10-2)筛查早期中心性青光眼损害。
- 建议结合OCT概率图与10-2视野进行地形图分析以识别早期中心性损害。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We sought to test the hypothesis that a recently proposed pattern standard deviation (PSD) metric, based upon the 24-2 visual field (VF) test, as well as the PSD of the 10-2 VF, will miss central glaucomatous damage confirmed with an objective structure-function method. DESIGN: Cross-sectional study. METHODS: A glaucoma (G) group (70 eyes/patients) diagnosed with glaucoma and a 24-2 mean deviation better than -6 dB and a healthy (H) group (45 eyes/patients) had 24-2 and 10-2 VFs and optical coherence tomography (OCT) scans twice within 4 weeks. The PSD(C24-2), based upon the central 12 points of the 24-2, was compared with the PSD(10-2). To evaluate central damage (CD) in G eyes with normal PSD(C24-2) values, a post hoc analysis was combined with a CD reference standard (CD-RS), which was based upon an objective, topographic comparison between abnormal points on the 10-2 VF and OCT probability maps. RESULTS: The 115 PSD(C24-2) and PSD(10-2) values were significantly correlated (Spearman correclation coefficient: rho = 0.55; P < .001) and the number of G eyes (19) identified as abnormal by the PSD(C24-2) was not significantly different from the number (22) identified by the PSD(10-2) (P = .15). However, based upon the CD-RS, 44 of 70 G eyes were classified as abnormal. The PSD(C24-2) missed 27 (61%) of these 44 eyes, and the PSD(10-2) missed 23 (52%) of these eyes. Post hoc analysis revealed clear CD in most of these eyes. CONCLUSION: Neither the PSD(C24-2) nor the PSD(10-2) metric is good measure of early CD. Instead we recommend a topographic approach based upon OCT probability maps and a 10-2 VF.
引用
- Hood DC, Thenappan AA, Tsamis E, et al. An Evaluation of a New 24-2 Metric for Detecting Early Central Glaucomatous Damage. Am J Ophthalmol. 2020. PMID: 32777374. doi:10.1016/j.ajo.2020.07.045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。