文献速递青光眼

视野检查中种子点误差评估策略(SPEAR)在正常眼、可疑青光眼及青光眼患者中的应用

A Strategy for Seeding Point Error Assessment for Retesting (SPEAR) in Perimetry Applied to Normal Subjects, Glaucoma Suspects, and Patients With Glaucoma.
PubMed 文献 · Am J Ophthalmol · 2020-08-08

该横断面研究基于364眼(77正常眼、178可疑青光眼、109青光眼)建立识别种子点误差(SPE)的模型,并在两个测试队列中前瞻性验证。SITA-Faster的不靠谱结果率(30%-49.7%)高于SITA-Standard(10.8%-16.6%),SPE是SITA-Faster不靠谱结果的主因(57.5%-64.9%)。最佳模型(9个测试位点)识别SPE的ROC曲线下面积为0.89。

要点

  • SITA-Faster的不靠谱视野结果率高于SITA-Standard,SPE是主要原因。
  • 存在SPE的SITA-Faster结果全局指数更差且敏感度下降簇更多。
  • 基于9个测试位点的模型可早期识别SPE,AUC为0.89。

核心结论

  • 种子点误差(SPE)是视野检查结果不靠谱的重要原因,尤其在SITA-Faster算法下。
  • 所提出的模型可在检查早期识别SPE,并指导使用两种SITA算法进行重测。

研究设计与样本

  • 横断面研究,使用364眼(77正常眼、178可疑青光眼眼、109青光眼眼)的视野结果建立识别SPE的模型。
  • 两个测试队列(326眼行SITA-Faster,327青光眼眼行SITA-Standard)用于前瞻性评估模型识别SPE的性能。

主要发现

  • 测试队列中,SITA-Faster的不靠谱视野结果率为30%-49.7%,SITA-Standard为10.8%-16.6%。
  • SITA-Faster中SPE贡献了多数不靠谱结果(57.5%-64.9%),而SITA-Standard中多数不靠谱结果由注视跟踪偏移导致(40%-77.8%)。
  • SITA-Faster中,存在SPE的结果比可靠结果的全局指数更差且敏感度下降簇更多。
  • 最佳模型(使用9个测试位点)识别SPE的ROC曲线下面积为0.89。

关键数值与推荐

  • SITA-Faster不靠谱结果率30%-49.7%,SITA-Standard为10.8%-16.6%。
  • SITA-Faster中SPE占不靠谱结果的57.5%-64.9%,SITA-Standard中注视跟踪偏移占40%-77.8%。
  • 最佳SPE识别模型(9个测试位点)的AUC为0.89。

临床怎么用

  • 在SITA-Faster视野检查中应警惕SPE导致的不靠谱结果,可应用所提模型早期识别SPE并指导重测。
  • 为视野检查技师提供简化框架以提高测试结果的整体保真度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We sought to determine the impact of seeding point errors (SPEs) as a source of low test reliability in perimetry and to develop a strategy to mitigate this error early in the test. DESIGN: Cross-sectional study. METHODS: Visual field test results from 1 eye of 364 patients (77 normal eyes, 178 glaucoma suspect eyes, and 109 glaucoma eyes) were used to develop models for identifying SPE. Two test cohorts (326 undertaking Swedish interactive thresholding algorithm [SITA]-Faster and 327 glaucoma eyes undertaking SITA-Standard) were used to prospectively evaluate the models for identifying SPEs. Global visual field metrics were compared among reliable and unreliable results. Regression models were used to identify factors distinguishing SPEs from non-SPEs. Models were evaluated using receiver operating characteristic (ROC) curves. RESULTS: In the test cohorts, SITA-Faster produced a higher rate of unreliable visual field results (30%-49.7%) compared with SITA-Standard (10.8%-16.6%). SPEs contributed to most of the unreliable results in SITA-Faster (57.5%-64.9%) compared with gaze tracker deviations accounting for most of the unreliable results in SITA-Standard (40%-77.8%). In SITA-Faster, results with SPEs had worse global indices and more clusters of sensitivity reduction than reliable results. Our best model (using 9 test locations) can identify SPEs with an area under the ROC curve of 0.89. CONCLUSION: SPEs contribute to a large proportion of unreliable visual field test results, particularly when using SITA-Faster. We propose a useful model for identifying SPEs early in the test that can then guide retesting using both SITA algorithms. We provide a simplified framework for the perimetrist to improve the overall fidelity of the test result.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Phu J, Kalloniatis M. A Strategy for Seeding Point Error Assessment for Retesting (SPEAR) in Perimetry Applied to Normal Subjects, Glaucoma Suspects, and Patients With Glaucoma. Am J Ophthalmol. 2020. PMID: 32777379. doi:10.1016/j.ajo.2020.07.047

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。