高度近视黄斑裂孔羊膜移植术后旁中心凹萎缩
这项回顾性介入病例系列纳入10例高度近视(眼轴>26.5 mm)黄斑裂孔患者,行人类羊膜移植。术后70%裂孔闭合,最佳矫正视力从1.26 logMAR改善至1.11 logMAR(p=0.074),40%术眼在术后首月出现旁中心凹萎缩样脱色素,未见视力恶化及移植物排斥。
要点
- 高度近视黄斑裂孔行羊膜移植术后40%出现旁中心凹萎缩样脱色素。
- 70%术眼黄斑裂孔完全闭合,视力改善未达统计学显著(p=0.074)。
- 旁中心凹萎缩组与无萎缩组在眼轴、裂孔大小及视力上无显著差异。
核心结论
- 高度近视黄斑裂孔行人类羊膜移植术后40%术眼出现旁中心凹萎缩,发病机制与远期影响待研究。
研究设计与样本
- 回顾性介入病例系列,纳入两家医院10例(10眼)高度近视(眼轴>26.5 mm)黄斑裂孔患者,行人类羊膜移植。
主要发现
- 术后7眼(70%)黄斑裂孔完全闭合,平均最佳矫正视力从术前1.26 logMAR改善至末次随访1.11 logMAR(p=0.074)。
- 4眼(40.0%)在术后首月出现黄斑裂孔病灶周围斑片状萎缩样脱色素,均无视力恶化。
- 伴与不伴旁中心凹萎缩者在人口学、眼轴、裂孔大小、眼部病史及术前术后最佳矫正视力上无显著差异。
- 随访期间未发生移植物排斥和炎症。
关键数值与推荐
- 术前平均眼轴29.9±1.8 mm,平均黄斑裂孔直径881.8±438.5 μm。
临床怎么用
- 高度近视黄斑裂孔羊膜移植术后需用彩色眼底照相和结构OCT监测旁中心凹萎缩。
局限性
- 回顾性设计、样本量仅10眼、随访短期,旁中心凹萎缩的发病机制与长期结局未明。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To report the surgical outcome and postoperative hypopigmented change around fovea among patients with high myopia who received human amniotic membrane (hAM) graft transplantation for macular hole (MH). METHOD: This retrospective, interventional case series included 10 eyes of 10 consecutive patients (5 (50%) male) with high myopia (axial length over 26.5 mm) who received hAM graft to treat persisted or chronic MH with or without retinal detachment in two hospitals. Postoperative parafoveal atrophy was identified with colour fundus picture and structure optical coherent tomography. Baseline characteristics and short-term visual outcome were analysed. RESULTS: The preoperative mean (±SD) axial length and MH diameter were 29.9 (±1.8) mm and 881.8 (±438.5) μm, respectively. After hAM transplantation, seven (70%) eyes had complete MH closure and the mean best-corrected visual acuity (BCVA) improved from 1.26 (±0.48) logarithm of minimal angle of resolution (logMAR) before operation to 1.11 (±0.44) logMAR on the last visit (p=0.074). Patchy atrophy-like depigmentation developed around the MH lesion in four (40.0%) eyes as early as in the first month after surgery. None of them had visual worsening. In terms of demographics, axial length, MH size, ocular history, preoperative BCVA and postoperative BCVA, there was no significant difference between those with and without the parafoveal atrophy. No graft rejection and inflammation happened during the follow-up. CONCLUSION: Parafovea atrophy, a rare complication in the conventional MH surgery, was observed in 40% of eyes with highly myopic MH after hAM graft transplantation. The pathogenesis and long-term consequence need further investigations.
引用
- Tsai DC, Huang YH, Chen SJ, et al. Parafoveal atrophy after human amniotic membrane graft for macular hole in patients with high myopia. Br J Ophthalmol. 2020. PMID: 32737034. doi:10.1136/bjophthalmol-2019-315603
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。