文献速递眼底病与葡萄膜炎

心肺适能与握力同年龄相关性黄斑变性无关:基于人群的横断面研究

Association between cardiorespiratory fitness and handgrip strength with age-related macular degeneration: a population-based study.
PubMed 文献 · Br J Ophthalmol · 2020-08-28

该研究基于波美拉尼亚健康研究(2008-2012)1173名20-79岁成人的横断面数据,采用非散瞳眼底照相按临床标准分级诊断年龄相关性黄斑变性(AMD),并通过标准化心肺运动试验测量峰值摄氧量(peakVO2)、无氧阈摄氧量(VO2@AT)和最大功率输出(Wmax),以握力计测量握力。多因素泊松回归分析显示,上述四项指标与AMD均无关联,校正后患病率比(PR)分别为1.05、0.96、1.10和1.01。结论认为心肺适能和握力与AMD无关,但需更大样本的纵向研究进一步验证。

要点

  • 心肺适能三项指标(peakVO2、VO2@AT、Wmax)与AMD患病率均无显著关联。
  • 握力与AMD也无关联,校正PR为1.01(95%CI 0.79-1.30)。
  • 年龄、性别、吸烟、BMI和糖尿病未修饰上述关联。

核心结论

  • 在本研究人群中,心肺适能和握力与年龄相关性黄斑变性无关联。

研究设计与样本

  • 基于人群的横断面研究,纳入波美拉尼亚健康研究2008-2012年1173名20-79岁成年男女。
  • 采用非散瞳眼底照相并由经验丰富的阅片者按既定临床AMD分级量表进行分级。
  • 心肺适能通过自行车测力计标准化心肺运动试验(改良Jones方案)测量peakVO2、VO2@AT和Wmax,握力用便携式测力计评估。
  • 采用多因素泊松回归模型计算校正患病率比(PR)。

主要发现

  • peakVO2每增加1个标准差,AMD校正PR为1.05(95%CI 0.82-1.34)。
  • VO2@AT每增加1个标准差,AMD校正PR为0.96(95%CI 0.78-1.18)。
  • Wmax每增加1个标准差,AMD校正PR为1.10(95%CI 0.86-1.41)。
  • 握力每增加1个标准差,AMD校正PR为1.01(95%CI 0.79-1.30)。
  • 上述关联未受年龄、性别、吸烟、体质指数和糖尿病的修饰,敏感性分析结果相似。

临床怎么用

  • 基于当前横断面证据,心肺适能和握力不宜作为AMD风险评估或筛查的独立指标。

局限性

  • 横断面设计无法推断因果关系。
  • 作者指出仍需更大样本的纵向研究来进一步检验这些关联。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To assess whether cardiorespiratory fitness (CRF) and handgrip strength, two objective markers of physical fitness, are associated with age-related macular degeneration (AMD). METHODS: We analysed cross-sectional data from the population-based Study of Health in Pomerania (2008-2012) including 1173 adult men and women aged 20-79 years. Fundus photography of the central retina was recorded with a non-mydriatic camera, and images were graded according to an established clinical AMD classification scale by an experienced reader. CRF was measured using peak oxygen uptake (peakVO2), oxygen uptake at the anaerobic threshold (VO2@AT), and maximum power output (Wmax) from standardised cardiopulmonary exercise testing on a bicycle ergometer according to a modified Jones protocol. Handgrip strength was assessed using a handheld dynamometer. Adjusted prevalence ratios (PR) for the associations of peakVO2, VO2@AT, Wmax and handgrip strength with AMD were derived from multivariable Poisson regression models. RESULTS: PeakVO2, VO2@AT, Wmax and handgrip strength were not associated with AMD. Adjusted PR for AMD associated with a 1-SD increment in peakVO2, VO2@AT, Wmax and handgrip strength were 1.05 (95% CI 0.82 to 1.34), 0.96 (95% CI 0.78 to 1.18), 1.10 (95% CI 0.86 to 1.41) and 1.01 (95% CI 0.79 to 1.30), respectively. These associations were not modified by age, sex, smoking, body mass index and diabetes. Estimates in sensitivity analysis for confounding, selection bias and missing data were similar. CONCLUSION: In our study, CRF and handgrip strength were not associated with AMD. Nevertheless, longitudinal studies with bigger sample sizes are needed to furtherly examine these associations.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。