飞秒激光辅助深板层角膜移植术治疗圆锥角膜的多术者结果
该单中心回顾性比较研究分析了飞秒激光辅助深板层角膜移植术(F-DALK)与手动非激光深板层角膜移植术(M-DALK)治疗圆锥角膜的临床结局。结果显示F-DALK组术中后弹力层穿孔率和转行穿透性角膜移植术(PK)的比例均显著低于M-DALK组,而拆线后矫正远视力(CDVA)≥20/40的比例两组无显著差异。
核心结论
- 在多位术者参与的公立医疗环境中,飞秒激光辅助DALK的部分步骤自动化可能降低圆锥角膜患者术中后弹力层穿孔率和转行PK的风险。
研究设计与样本
- 单中心、比较性、回顾性干预性病例系列,纳入连续圆锥角膜病例:F-DALK组为2015年8月1日至2018年9月1日接受大泡法F-DALK的58眼(55例),M-DALK组为2012年9月1日至2016年9月30日接受大泡法M-DALK的326眼(309例),地点为伦敦Moorfields眼科医院。
临床怎么用
- 对于圆锥角膜行DALK,采用飞秒激光辅助可能减少术中后弹力层穿孔和转行PK,但需结合术者经验与设备条件权衡。
局限性
- 回顾性设计、单中心、非随机分组,F-DALK与M-DALK手术时间段不同,可能存在选择偏倚和混杂因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the clinical outcomes in femtosecond laser-assisted deep anterior lamellar keratoplasty (F-DALK) to manual non-laser deep anterior lamellar keratoplasty (M-DALK) for keratoconus in a multi-surgeon public healthcare setting. DESIGN: Single-center, comparative, retrospective interventional case series. METHODS: Population: Consecutive cases of keratoconus treated with big-bubble F-DALK from August 1, 2015, to September 1, 2018 and big-bubble M-DALK from September 1, 2012, to September 30, 2016. SETTING: Moorfields Eye Hospital, London. OBSERVATIONS: Data on preoperative status, operative details, intraoperative and postoperative complications, secondary interventions, and visual outcomes were archived on a customized spreadsheet for analysis. MainOutcomeMeasures: Rate of intraoperative perforation and conversion to penetrating keratoplasty (PK) and the percentage of patients, post removal of sutures (ROS), with corrected distance visual acuity (CDVA) ≥20/40. RESULTS: We analyzed 58 eyes of 55 patients who underwent F-DALK and 326 eyes of 309 patients who underwent M-DALK. Intraoperative perforation of Descemet membrane occurred in 15 of 58 (25.9%) F-DALK cases compared to 148 of 326 (45.4%) M-DALK cases (P = .006). Intraoperative conversion to PK was carried out in 2 of 58 (3.4%) F-DALK cases compared to 80 of 326 (24.5%) M-DALK cases (P = .001). Post ROS, 86.5% of F-DALK eyes had a CDVA of ≥20/40 (15 ± 7.3 months after surgery) compared to 83.7% of M-DALK eyes (24.9 ± 10.6 months) (P = .825). CONCLUSION: Laser automation of some steps in DALK for keratoconus may reduce the rate of intraoperative Descemet perforation and the conversion to PK in a multi-surgeon setting.
引用
- Gadhvi KA, Romano V, Fernández-Vega Cueto L, et al. Femtosecond Laser-Assisted Deep Anterior Lamellar Keratoplasty for Keratoconus: Multi-surgeon Results. Am J Ophthalmol. 2020. PMID: 32707206. doi:10.1016/j.ajo.2020.07.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。