飞秒激光辅助白内障手术与传统超声乳化手术随机对照试验的12个月结果
基质内飞秒激光辅助散光角膜切开术(iFAK)在散光矫正上可能优于手动角膜缘松解切口(LRI)。
要点
- FLACS与CPS在12个月时视力、屈光及不良事件无显著差异。
- 两组患者报告结局(Cat-PROM5、EQ-5D-3L)无显著差异。
- iFAK较LRI显示更大的矫正指数和更小的差异向量。
核心结论
- FLACS与CPS在12个月时视力、屈光、术后不良事件及患者报告结局方面无差异。
- iFAK相比LRI可能在术后12个月提供更有效的散光矫正。
主要发现
- FLACS组和CPS组平均LogMAR裸眼远视力分别为0.12(0.18)和0.13(0.19),p=0.68,95%CI -0.06至0.04。
- FLACS组和CPS组平均球镜等效屈光度分别为-0.1±0.6 D和-0.2±0.6 D,p=0.44,95%CI -0.09至0.21。
- FLACS组和CPS组平均矫正远视力分别为-0.01(0.1)和0(0.1),p=0.45,95%CI -0.04至0.02。
- 每组各有2例因后囊膜混浊行YAG激光后囊切开术,p=1。
关键数值与推荐
- 平均内皮细胞丢失(每mm²±SD)FLACS组为301±320,CPS组为228±303,p=0.07,95%CI -7.26至153.26。
- 平均Cat-PROM评分(±SD)FLACS组为-5.5(2.6),CPS组为-5.8(2.5),p=0.3,95%CI 0.31至1.01。
- EQ-5D-3L平均指数评分(±SD)FLACS组为0.92(0.13),CPS组为0.89(0.14),p=0.1,95%CI -0.1至0.01。
- 矢量分析显示iFAK相比手动LRI具有更大的矫正指数(p=0.02;95%CI 0.06至0.60)和更小的差异向量(p=0.046;95%CI -0.54至-0.01)。
临床怎么用
- FLACS与CPS在12个月结局上无明显差异,选择术式时可综合考虑其他因素。
- 对于需要散光矫正的患者,iFAK可能比手动LRI更有效。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To report 12-month outcomes of randomised controlled trial comparing conventional phacoemulsification surgery (CPS) with femtosecond laser-assisted cataract surgery (FLACS). METHODS: This was a single-centre, prospective single-masked randomised case-controlled trial. Four hundred patients were randomised to CPS or FLACS with the LenSx platform (Alcon Laboratories Inc.). Visual acuity, refraction, central corneal thickness, endothelial cell loss (ECL), adverse events and quality of life outcomes, using EuroQOL 5-dimensions (EQ-5D-3 L) and cataract surgery patient-reported outcome measures (PROMs) questionnaires (Cat-PROM5), were recorded. RESULTS: Two hundred and thirty four patients (58.5%) attended 12-month follow-up (116 FLACS, 118 CPS). Mean LogMAR unaided distance visual acuity) (±SD) was 0.12 (0.18) with FLACS and 0.13 (0.19) with CPS (p=0.68; 95% Confidence Interval [CI]-0.06,0.04). Mean spherical equivalent (SE) refraction was -0.1±0.6 diopters (D) with FLACS and -0.2±0.6 D with CPS (p=0.44; 95% CI -0.09, 0.21). Mean corrected distance visual acuity (±SD) was -0.01 (0.1) with FLACS and 0(0.1) with CPS (p=0.45; 95% CI -0.04,0.02). Two patients per group underwent YAG laser capsulotomy for posterior capsular opacification (p=1). Mean ECL (per mm2±SD) was 301±320 with FLACS and 228±303 with CPS (p=0.07; 95% CI -7.26, 153.26). Mean Cat-PROM scores (±SD) were -5.5 (2.6) with FLACS and -5.8 (2.5) with CPS (p=0.3; 95% CI 0.31,1.01). EQ5-3DL mean index score (±SD) was 0.92 (0.13) with FLACS and 0.89 (0.14) with CPS (p=0.1; 95% CI -0.1, 0.01). Vector analysis comparing manual limbal relaxing incisions (LRIs) and intrastromal femtosecond laser-assisted astigmatic keratotomies (iFAKs) showed a greater correction index (p=0.02; 95% CI 0.06 to 0.60) and smaller difference vector (p=0.046; 95% CI -0.54, -0.01) with iFAK. CONCLUSIONS: There were no differences in vision, refraction, adverse postoperative events or PROMs between FLACS and CPS groups at 12 months. iFAKs may provide more effective astigmatic correction compared to LRIs, 12 months postoperatively.
引用
- Stanojcic N, Roberts HW, Wagh VK, et al. A randomised controlled trial comparing femtosecond laser-assisted cataract surgery versus conventional phacoemulsification surgery: 12-month results. Br J Ophthalmol. 2020. PMID: 32699049. doi:10.1136/bjophthalmol-2020-316311
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。