青光眼中心视野等效输入噪声升高:是否源于视网膜神经节细胞采样不足?
该研究纳入21例青光眼患者和23例年龄匹配的正常视力者,通过外部噪声下朝向判别阈值测量并结合线性放大器模型,发现青光眼患者等效输入噪声显著增大而计算效率无显著差异,且等效输入噪声与Pelli-Robson对比敏感度和黄斑视网膜神经节细胞计数显著相关。
要点
- 青光眼患者中心视野对比敏感度下降与等效输入噪声增大相关,计算效率无显著变化。
- 等效输入噪声与Pelli-Robson对比敏感度和黄斑视网膜神经节细胞计数显著相关。
- 模型分析提示视网膜采样不足可能通过增加等效输入噪声影响中心视力。
核心结论
- 青光眼患者中心视野的等效输入噪声显著升高,进而损害中心凹对比敏感度。
- 视网膜水平采样不足可能增加等效输入噪声。
研究设计与样本
- 研究纳入21例青光眼患者和23例年龄匹配的正常视力者。
- 通过正弦光栅嵌入不同水平外部噪声测量朝向判别阈值对比度,并拟合线性放大器模型分解对比敏感度。
- 将结构(频域光学相干断层扫描)和功能(标准自动视野计SITA 10-2)数据估算的黄斑视网膜神经节细胞计数与等效输入噪声或计算效率进行相关分析。
- 通过分析推导和计算机模拟,在线性放大器模型中加入视网膜神经节细胞采样模块,评估视网膜采样不足对等效输入噪声和计算效率的相对影响。
主要发现
- 与正常对照相比,青光眼患者等效输入噪声显著增大,计算效率无显著差异。
- 等效输入噪声与Pelli-Robson对比敏感度和黄斑视网膜神经节细胞计数显著相关。
- 分析推导和模型模拟结果显示,等效输入噪声可表达为内部噪声和视网膜采样的函数。
临床怎么用
- 在青光眼中心视力评估中,等效输入噪声可作为对比敏感度下降的机制性指标。
- 黄斑视网膜神经节细胞计数与等效输入噪声相关,提示结构-功能关联。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Recent evidence shows that macular damage is common even in early stages of glaucoma. Here we investigated whether contrast sensitivity loss in the central vision of glaucoma patients is due to an increase in equivalent input noise (Neq), a decrease in calculation efficiency, or both. We also examined how retinal undersampling resulting from loss of retinal ganglion cells (RGCs) may affect Neq and calculation efficiency. METHODS: This study included 21 glaucoma patients and 23 age-matched normally sighted individuals. Threshold contrast for orientation discrimination was measured with a sinewave grating embedded in varying levels of external noise. Data were fitted to the linear amplifier model (LAM) to factor contrast sensitivity into Neq and calculation efficiency. We also correlated macular RGC counts estimated from structural (spectral-domain optical coherence tomography) and functional (standard automated perimetry Swedish interactive thresholding algorithm 10-2) data with either Neq or efficiency. Furthermore, using analytical and computer simulation approach, the relative effect of retinal undersampling on Neq and efficiency was evaluated by adding the RGC sampling module into the LAM. RESULTS: Compared with normal controls, glaucoma patients exhibited a significantly larger Neq without significant difference in efficiency. Neq was significantly correlated with Pelli-Robson contrast sensitivity and macular RGC counts. The results from analytical derivation and model simulation further demonstrated that Neq can be expressed as a function of internal noise and retinal sampling. CONCLUSIONS: Our results showed that equivalent input noise is significantly elevated in glaucomatous vision, thereby impairing foveal contrast sensitivity. Our findings further elucidated how undersampling at the retinal level may increase equivalent input noise.
引用
- Liu R, Kwon M. Increased Equivalent Input Noise in Glaucomatous Central Vision: Is it Due to Undersampling of Retinal Ganglion Cells? Invest Ophthalmol Vis Sci. 2020. PMID: 32645132. doi:10.1167/iovs.61.8.10
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。