文献速递青光眼

早期青光眼尽管对比敏感度下降但阈上对比度感知未改变

Unaltered Perception of Suprathreshold Contrast in Early Glaucoma Despite Sensitivity Loss.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2020-01-01

本研究纳入20例伴部分视野缺损的青光眼患者和20名年龄相仿的健康对照,测量Gabor刺激的对比度检测阈值,并将中心Gabor的对比度与外围Gabor(固定为阈值2倍或4倍)进行匹配。结果显示青光眼患者视野缺损内检测阈值升高,但对可见阈上刺激的对比度感知与健康对照相似,提示视觉系统可能对敏感度损失存在补偿。

要点

  • 青光眼患者视野缺损内对比度检测阈值较对照升高0.141±0.026(P<0.001)。
  • 对2倍阈值参考刺激,缺损内匹配对比度比值与对照相似(平均低0.033±0.066,P=0.87)。
  • 对4倍阈值参考刺激,三组匹配对比度比值相似(P=0.58)。

核心结论

  • 尽管对比敏感度下降,青光眼患者对可见阈上刺激的对比度感知与健康对照相似。
  • 结果提示视觉系统可能对敏感度损失存在补偿。

研究设计与样本

  • 研究纳入20例伴部分视野缺损的青光眼患者(平均年龄72±7岁)和20名年龄相仿的健康对照(平均年龄70±7岁)。
  • 测量四种空间频率(0.5、1.0、2.0、4.0 c/deg)Gabor刺激(SD,0.75°)在10°偏心度处的对比度检测阈值,包括青光眼患者视野缺损内和缺损外。
  • 将中心Gabor的对比度与外围Gabor(对比度固定为检测阈值的2倍或4倍)进行匹配。
  • 数据采用线性混合模型分析。

主要发现

  • 与对照相比,青光眼患者检测阈值在视野缺损外升高0.05±0.025(Michelson单位,±SE;P=0.12),在视野缺损内升高0.141±0.026(P<0.001)。
  • 对2倍检测对比度的参考刺激,青光眼患者缺损外匹配对比度比值较缺损内高0.16±0.039(P<0.001)。
  • 青光眼患者缺损内匹配对比度比值与对照相似(平均低0.033±0.066;P=0.87)。
  • 对4倍检测对比度的参考刺激,三组匹配对比度比值相似(P=0.58)。
  • 空间频率对匹配对比度比值影响极小。

临床怎么用

  • 在早期青光眼评估中,检测阈值升高不一定反映患者对日常高对比度物体的主观对比度感知下降。
  • 对于可见的阈上刺激,青光眼患者的对比度感知可能与健康人相似,临床解释需结合检测与感知层面。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Glaucoma raises contrast detection thresholds, but our natural visual environment is dominated by high contrast that may remain suprathreshold in early to moderate glaucoma. This study investigates the effect of glaucoma on the apparent contrast of visible stimuli. METHODS: Twenty participants with glaucoma with partial visual field defects (mean age, 72 ± 7 years) and 20 age-similar healthy controls (mean age, 70 ± 7 years) took part. Contrast detection thresholds for Gabor stimuli (SD, 0.75°) of four spatial frequencies (0.5, 1.0, 2.0, and 4.0 c/deg) were first measured at 10° eccentricity, both within and outside of visual field defects for participants with glaucoma. Subsequently, the contrast of a central Gabor was matched to that of a peripheral Gabor with contrast fixed at two times or four times the detection threshold. Data were analyzed by linear mixed modelling. RESULTS: Compared with controls, detection thresholds for participants with glaucoma were raised by 0.05 ± 0.025 (Michelson units, ± SE; P = 0.12) and by 0.141 ± 0.026 (P < 0.001) outside and within visual field defects, respectively. For reference stimuli at two times the detection contrast, matched contrast ratios (matched/reference contrast) were 0.16 ± 0.039 (P < 0.001) higher outside compared with within visual field defects in participants with glaucoma. Matched contrast ratios within visual field defects were similar to controls (mean 0.033 ± 0.066 lower; P = 0.87). For reference stimuli at four times the detection contrast, matched contrast ratios were similar across all three groups (P = 0.58). Spatial frequency had a minimal effect on matched contrast ratios. CONCLUSIONS: Despite decreased contrast sensitivity, people with glaucoma perceive the contrast of visible suprathreshold stimuli similarly to healthy controls. These results suggest possible compensation for sensitivity loss in the visual system.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Bham HA, Dewsbery SD, Denniss J, et al. Unaltered Perception of Suprathreshold Contrast in Early Glaucoma Despite Sensitivity Loss. Invest Ophthalmol Vis Sci. 2020. PMID: 32676636. doi:10.1167/iovs.61.8.23

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。