文献速递眼底病与葡萄膜炎白内障与屈光手术眼外伤

8-0聚丙烯缝线环套与反手结:经结膜四点巩膜固定Akreos Adapt人工晶状体

8-0 Polypropylene Suture Looping and Overhand Knot: Transconjunctival Approach to Four-Point Scleral Fixation of an Akreos Adapt Intraocular Lens.
PubMed 文献 · Retina · 2020-06-26

本研究评估一种使用8-0聚丙烯缝线环套与反手结经巩膜固定带四个空心襻人工晶状体的新技术。在11例无晶状体或晶状体脱位患者的13只眼中,术后最佳矫正视力从术前平均0.71±0.58 logMAR提高至末次随访0.24±0.25 logMAR(P<0.05),未观察到玻璃体出血、低眼压、缝线暴露或瞳孔夹持。

要点

  • 8-0聚丙烯缝线通过反手结与10-0缝线连接,可四点固定带空心襻的Akreos Adapt人工晶状体。
  • 13只眼术后视力显著改善,末次随访平均logMAR视力0.24±0.25(Snellen 20/35)。
  • 未见玻璃体出血、低眼压、缝线暴露或瞳孔夹持等并发症。

核心结论

  • 新型经结膜四点巩膜固定技术使用8-0聚丙烯缝线环套与反手结,可安全有效地固定带四个空心襻的人工晶状体。

研究设计与样本

  • 前瞻性技术评估研究,纳入11例(13只眼)无晶状体或晶状体脱位患者,接受8-0聚丙烯缝线四点巩膜固定Akreos Adapt人工晶状体。

主要发现

  • 术前平均矫正远视力为0.71±0.58 logMAR(Snellen 20/103),末次随访提高至0.24±0.25 logMAR(Snellen 20/35),差异有统计学意义(P<0.05)。
  • 所有患眼均未观察到玻璃体出血、低眼压、缝线暴露或人工晶状体瞳孔夹持。

关键数值与推荐

  • 使用8-0聚丙烯缝线通过反手结与10-0聚丙烯缝线连接,缝线结通过旋转埋入巩膜隧道。
  • 术后评估最佳矫正视力、眼压和并发症。

临床怎么用

  • 该技术可为无晶状体或晶状体脱位患者提供四点巩膜固定人工晶状体的选项,反手结设计允许使用8-0聚丙烯缝线以期长期安全,且可能无需术者学习全新技术。

局限性

  • 样本量小(11例13只眼),随访时间未在摘要中报告,缺乏对照组。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate a novel surgical technique for transscleral fixation of the intraocular lens (IOL) with four hollow haptics using 8-0 polypropylene suture looping and overhand knot. METHODS: An 8-0 polypropylene suture was tied to a 10-0 polypropylene suture with an overhand knot. One set of 8-0 polypropylene suture was then passed through the IOL four haptics. The suture knot was buried by rotating into the sclera tunnel. Best-corrected visual acuity, intraocular pressure, and complications were determined. RESULTS: The IOLs were fixed with using an 8-0 polypropylene suture in 13 eyes of 11 patients with aphakia and dislocated crystalline lens. The mean preoperative corrected distance visual acuity was 0.71 ± 0.58 logarithm of the minimum angle of resolution (Snellen 20/103), and it improved to 0.24 ± 0.25 logarithm of the minimum angle of resolution (Snellen 20/35) at the final follow-up ( P < 0.05). No vitreous hemorrhage, hypotony, suture exposed, and pupillary capture of the IOL were observed in any of the patients. CONCLUSION: The authors have developed a new technique for transscleral IOL fixation with one set of an 8-0 polypropylene suture tied to a 10-0 polypropylene suture with an overhand knot. The overhand knot offers the opportunity to use an 8-0 polypropylene suture for the long-term safety and may not require the surgeon to learn any new technique.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Chen S, Yuan G, Zhu W, et al. 8-0 Polypropylene Suture Looping and Overhand Knot: Transconjunctival Approach to Four-Point Scleral Fixation of an Akreos Adapt Intraocular Lens. Retina. 2020. PMID: 32604345. doi:10.1097/IAE.0000000000002873

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。