文献速递眼底病与葡萄膜炎

微视野与低亮度视力缺陷对预测年龄相关性黄斑变性进展的附加价值

Examining the added value of microperimetry and low luminance deficit for predicting progression in age-related macular degeneration.
PubMed 文献 · Br J Ophthalmol · 2020-06-30

研究纳入140例双眼大玻璃膜疣受试者,基線行微视野、视力及彩色眼底照相(CFP)检查,每6个月随访至36个月以判定晚期AMD进展。基線微视野点敏感度标准差(PSD)和色素异常均与进展时间显著相关(p≤0.004),低亮度视力缺陷(LLD)则不相关(p=0.471);微视野PSD和LLD单独预测进展的AUC(0.68和0.58)均低于CFP色素异常分级(AUC=0.80;均p<0.005),且将微视野和/或LLD加入CFP模型未改善预测性能(AUC均为0.80;均p≥0.66)。

要点

  • 基線微视野PSD和CFP色素异常与晚期AMD进展时间显著相关(p≤0.004),LLD不相关(p=0.471)。
  • 微视野PSD单独预测进展的AUC=0.68,低于CFP色素异常分级的AUC=0.80(p<0.005)。
  • 将微视野和/或LLD加入CFP模型未改善预测性能(AUC均为0.80;均p≥0.66)。

核心结论

  • 微视野PSD在群体水平与AMD进展独立相关,但个体水平预测价值不及常规CFP色素异常分级。
  • LLD与AMD进展无显著关联,且微视野和/或LLD加入CFP模型均未改善预测性能。

研究设计与样本

  • 纳入140例双眼大玻璃膜疣受试者,基線行微视野、视力测量和CFP检查。
  • 每6个月随访至36个月,判定晚期AMD进展,并构建和检验预测模型。

主要发现

  • 基線微视野PSD和色素异常与进展时间显著相关(p≤0.004),LLD不相关(p=0.471)。
  • 微视野PSD单独预测进展的AUC=0.68,LLD单独预测的AUC=0.58。
  • CFP色素异常分级的AUC=0.80,显著高于微视野PSD和LLD单独预测(均p<0.005)。
  • 将微视野和/或LLD加入CFP模型后AUC均为0.80,未改善预测性能(均p≥0.66)。

临床怎么用

  • 在预测双眼大玻璃膜疣患者晚期AMD进展时,常规CFP色素异常分级仍为更优的预测指标。
  • 微视野和LLD在个体水平预测价值有限,暂不宜替代CFP用于进展风险分层。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To examine the added predictive value of microperimetric sensitivity and low luminance deficit (LLD; difference between photopic and low luminance visual acuity (VA)) to information from colour fundus photography (CFP) for progression to late age-related macular degeneration (AMD) in individuals with bilateral large drusen. METHODS: 140 participants with bilateral large drusen underwent baseline microperimetry testing, VA measurements and CFP. They were then reviewed at 6-monthly intervals to 36 months, to determine late AMD progression. Microperimetry pointwise sensitivity SD (PSD), LLD and the presence of pigmentary abnormalities on CFPs were determined. Predictive models based on these parameters were developed and examined. RESULTS: Baseline microperimetry PSD and presence of pigmentary abnormalities were both significantly associated with time to develop late AMD (p≤0.004), but LLD was not (p=0.471). The area under the receiver operating characteristic curve (AUC) for discriminating between eyes that progressed to late AMD based on models using microperimetry PSD (AUC=0.68) and LLD (AUC=0.58) alone was significantly lower than that based on CFP grading for the presence of pigmentary abnormalities (AUC=0.80; both p<0.005). Addition of microperimetry and/or LLD information to a model that included CFP grading did not result in any improvement in its predictive performance (AUC=0.80 for all; all p≥0.66). CONCLUSIONS: While microperimetry, but not LLD, was significantly and independently associated with AMD progression at the population level, this study observed that both measures were suboptimal at predicting progression at the individual level when compared to conventional CFP grading and their addition to the latter did not improve predictive performance.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Wu Z, Luu CD, Hodgson LA, et al. Examining the added value of microperimetry and low luminance deficit for predicting progression in age-related macular degeneration. Br J Ophthalmol. 2020. PMID: 32606079. doi:10.1136/bjophthalmol-2020-315935

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。