利用光学相干断层扫描生成后眼球定量地形曲率图
本研究基于「全眼」光学相干断层扫描(OCT)校正光学畸变,生成空间准确的后眼球OCT容积并创建局部曲率(KM,mm-1)地形图,对9例受试者(3例正常、2例近视性变性、4例视乳头水肿)成像。正常受试者颞侧KM均值0.0923 mm-1、鼻侧0.0927 mm-1、局部变异性0.0162 mm-1;近视性变性局部变异性更高(0.0836 mm-1);视乳头水肿鼻侧较颞侧更平坦(0.0709 vs. 0.0885 mm-1)。
要点
- OCT可生成后眼球局部曲率定量地形图,分辨率达微米级。
- 正常眼颞侧与鼻侧KM均值接近,局部变异性较低。
- 近视性变性局部曲率变异性增高,视乳头水肿鼻侧较颞侧平坦。
核心结论
- 基于OCT的定量后眼球地形方法能以微米级分辨率分析局部曲率,有望帮助临床医生和研究者更早识别细微局部视网膜变形并随访其发展。
研究设计与样本
- 方法学研究,使用「全眼」OCT校正受试者光学畸变,生成空间准确的后眼球OCT容积并创建局部曲率(KM,mm-1)地形图。
- 共对9例受试者成像,包括3例正常、2例近视性变性、4例视乳头水肿,其中1例视乳头水肿受试者接受纵向成像。
主要发现
- 正常受试者颞侧KM均值为0.0923 mm-1,鼻侧KM均值为0.0927 mm-1,KM局部变异性为0.0162 mm-1。
- 近视性变性受试者KM局部变异性更高,为0.0836 mm-1。
- 视乳头水肿受试者鼻侧KM较颞侧更平坦(0.0709 vs. 0.0885 mm-1)。
- 所有受试者平均会话内KM重复性为0.0036 mm-1。
临床怎么用
- 可利用OCT生成的后眼球局部曲率地形图定量分析局部曲率变化,辅助早期识别近视性变性或视乳头水肿等细微视网膜变形并纵向随访。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Deformations of the retina such as staphylomas in myopia or scleral flattening in high intracranial pressure can be challenging to quantify with en face imaging. We describe an optical coherence tomography-based method for the generation of quantitative posterior eye topography maps in normal and pathologic eyes. METHODS: Using "whole eye" optical coherence tomography, we corrected for subjects' optical distortions to generate spatially accurate posterior eye optical coherence tomography volumes and created local curvature (KM, mm-1) topography maps for each consented subject. We imaged nine subjects, three normal, two with myopic degeneration, and four with papilledema including one that was imaged longitudinally. RESULTS: Normal subjects mean temporal KM was 0.0923 mm-1, nasal KM was 0.0927 mm-1, and KM local variability was 0.0162 mm-1. In myopic degeneration, subjects KM local variability was higher at 0.0836 mm-1. In papilledema subjects nasal KM was flatter compared with temporal KM (0.0709 vs. 0.0885 mm-1). Mean intrasession KM repeatability for all subjects was 0.0036 mm-1. CONCLUSION: We have developed an optical coherence tomography based method for quantitative posterior eye topography that offers the ability to analyze local curvature with micron scale resolution and offers the potential to help clinicians and researchers characterize subtle, local retinal deformations earlier in patients and follow their development over time.
引用
- McNabb RP, Liu AS, Gospe SM, et al. QUANTITATIVE TOPOGRAPHIC CURVATURE MAPS OF THE POSTERIOR EYE UTILIZING OPTICAL COHERENCE TOMOGRAPHY. Retina. 2021. PMID: 32568982. doi:10.1097/IAE.0000000000002897
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。