文献速递角膜与眼表疾病

荧光SmartProbes快速检测角膜溃疡微生物分离株的探索性应用

Exploratory Use of Fluorescent SmartProbes for the Rapid Detection of Microbial Isolates Causing Corneal Ulcer.
PubMed 文献 · Am J Ophthalmol · 2020-06-20

该研究在印度南部转诊角膜门诊纳入267例疑似微生物性角膜炎患者,对角膜刮片应用荧光SmartProbes(BAC One或BAC Two)无需洗涤或进一步处理直接荧光显微镜评估,并与革兰染色比较。BAC One区分细菌/真菌的敏感度80.0%、特异度87.5%、准确率82.2;BAC Two区分革兰阴性菌的敏感度93.3%、特异度84.8%、NPV 99.2%、准确率85.6。结论认为荧光SmartProbes在角膜刮片中 delineating 革兰阳性/阴性菌或真菌方面与革兰染色相当,且敏感度、特异度、PPV、NPV和准确率等于或高于培养对革兰染色的比较。

要点

  • 荧光SmartProbes无需洗涤或进一步处理即可快速评估角膜刮片。
  • BAC One区分细菌/真菌的敏感度80.0%、特异度87.5%、准确率82.2。
  • BAC Two区分革兰阴性菌的NPV达99.2%、准确率85.6。

核心结论

  • 荧光SmartProbes可作为革兰染色的比较方法,用于角膜刮片中革兰阳性或阴性细菌或真菌的 delineating。
  • 该方法在敏感度、特异度、PPV、NPV和准确率上等于或高于培养对革兰染色的比较。
  • 该方法有潜力用于即时临床检测以辅助微生物性角膜炎的诊断。

研究设计与样本

  • 实验性研究,对诊断技术进行评估。
  • 在印度南部转诊角膜门诊连续收集267例疑似微生物性角膜炎患者的角膜刮片。
  • 角膜刮片滴加SmartProbes(BAC One或BAC Two)后直接荧光显微镜评估,无需样本洗涤或进一步处理,并与革兰染色结果比较。

主要发现

  • BAC One与革兰染色比较:敏感度80.0%、特异度87.5%、PPV 93.8%、NPV 65.1%、准确率82.2。
  • BAC Two与革兰染色比较:敏感度93.3%、特异度84.8%、NPV 99.2%、准确率85.6。
  • 培养结果与革兰染色比较:敏感度73.4%、特异度70.7%、PPV 86.5%、NPV 51.0%、总体准确率72.6。

关键数值与推荐

  • BAC One将SmartProbe标记样本判读为细菌/真菌/无。
  • BAC Two将SmartProbe标记样本判读为革兰阴性菌/无。

临床怎么用

  • 可在角膜刮片现场快速判读细菌/真菌及革兰阴性菌,作为革兰染色的替代或补充。
  • BAC Two的NPV 99.2%有助于在即时检测中排除革兰阴性菌。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To explore the use of optical SmartProbes for the rapid evaluation of corneal scrapes from patients with suspected microbial keratitis, as a clinical alternative to Gram stain. DESIGN: Experimental study with evaluation of a diagnostic technology. METHODS: Corneal scrapes were collected from 267 patients presenting with microbial keratitis at a referral cornea clinic in South India. Corneal scrapes were flooded with SmartProbes (BAC One or BAC Two) and evaluated by fluorescence microscopy (without the need for sample washing or further processing). The SmartProbe-labeled samples were scored as bacteria/fungi/none (BAC One) or gram-negative bacteria/none (BAC Two) and compared to Gram stain results. RESULTS: Compared to Gram stain, BAC One demonstrated sensitivity and specificity of 80.0% and 87.5%, respectively, positive and negative predictive values (PPV, NPV) of 93.8% and 65.1%, and an accuracy of 82.2. BAC Two demonstrated sensitivity and specificity of 93.3% and 84.8%, respectively, an NPV of 99.2%, and an accuracy of 85.6%. When the corresponding culture results were compared to the Gram stain result, the sensitivity and specificity were 73.4% and 70.7%, the PPV and NPVs were 86.5% and 51.0%, and overall accuracy was 72.6. CONCLUSIONS: Fluorescent SmartProbes offer a comparative method to Gram stain for delineating gram-positive or gram-negative bacteria or fungi within corneal scrapes. We demonstrate equivalent or higher sensitivity, specificity, PPV and NPVs, and accuracy than culture to Gram stain. Our approach has scope for point-of-care clinical application to aid in the diagnosis of microbial keratitis.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Gunasekaran R, Lalitha P, Megia-Fernandez A, et al. Exploratory Use of Fluorescent SmartProbes for the Rapid Detection of Microbial Isolates Causing Corneal Ulcer. Am J Ophthalmol. 2020. PMID: 32574778. doi:10.1016/j.ajo.2020.06.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。