三种单件式丙烯酸人工晶状体术后短期预测误差变化比较
随机临床试验纳入195眼,比较植入Alcon SN60WF、Hoya XY-1或AMO ZCB00V单件式丙烯酸人工晶状体后短期屈光预测误差(PE)变化;三组术后2个月内均向近视漂移,SN60WF组在2个月时PE及PE变化显著小于其他两组。
要点
- 三组术后1天至2个月均出现显著近视漂移(P < .0001)。
- 术后2个月SN60WF组PE显著小于XY-1和ZCB00V组(P ≤ .0006)。
- SN60WF组1天至2个月PE变化显著小于其他两组(P = .0062)。
核心结论
- 植入三种单件式丙烯酸IOL后2个月内MRSE和PE均显著向近视变化,SN60WF组变化小于XY-1和ZCB00V组。
研究设计与样本
- 随机临床试验,纳入195例患者的195眼,随机分配植入Alcon SN60WF、Hoya XY-1或AMO ZCB00V单件式丙烯酸IOL。
主要发现
- 术后1天和1个月时三组间MRSE和PE无显著差异。
- 术后2个月时SN60WF组MRSE和PE显著小于XY-1和ZCB00V组(P ≤ .0006)。
- 术后1天至2个月PE变化SN60WF组显著小于其他两组(P = .0062)。
- IOL类型、前房深度变化和角膜曲率变化与PE变化独立相关。
关键数值与推荐
- 术后1天至2个月三组MRSE和PE均显著向近视变化(P < .0001)。
- 术后2个月组间比较P ≤ .0006,PE变化组间比较P = .0062。
临床怎么用
- 选择单件式丙烯酸IOL时需考虑不同型号术后短期屈光稳定性差异。
- SN60WF在术后2个月内屈光预测误差变化较小,可能有利于早期屈光稳定。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare short-term changes in refractive prediction error (PE) after phacoemulsification among eyes receiving different types of single-piece acrylic intraocular lenses (IOLs). DESIGN: Randomized clinical trial. METHODS: A total of 195 eyes of 195 patients scheduled for implantation of a single-piece acrylic IOL were randomly assigned to receive 1 of 3 IOLs: 1) an Alcon model SN60WF, 2) a Hoya model XY-1, or 3) an AMO model ZCB00V. Manifest spherical equivalent (MRSE) value, PE, and changes in PE were examined at 1 day and at 1 and 2 months postoperatively and were compared among groups. RESULTS: The mean MRSE and PE significantly changed toward myopia between 1 day and 2 months postoperatively in all groups (P < .0001). The MRSE and PE did not differ significantly among groups at 1 day and 1 month postoperatively and were significantly smaller in the SN60WF group than in the XY-1 and ZCB00V groups at 2 months (P ≤ .0006). The PE change between 1 day and 2 months postoperatively was significantly smaller in the SN60WF group than in the other groups (P = .0062). IOL type and changes in anterior chamber depth and corneal curvature independently correlated with PE changes. CONCLUSIONS: The MRSE and PE showed a significant myopic change for 2 months postoperatively in eyes implanted with 1 of 3 types of single-piece acrylic IOLs and were significantly smaller in the SN60WF than in the XY-1 and ZCB00V groups. Changes in PE during the 2 postoperative months were smaller in the SN60WF IOLs than in the other IOLs, suggesting that postoperative refractive stability differs among single-piece acrylic IOLs.
引用
- Hayashi K, Yoshida M, Hayashi S, et al. Short-Term Changes in Prediction Error after Cataract Surgery in Eyes Receiving 1 of 3 Types of Single-Piece Acrylic Intraocular Lenses. Am J Ophthalmol. 2020. PMID: 32479807. doi:10.1016/j.ajo.2020.05.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。