文献速递白内障与屈光手术

13种人工晶状体度数计算公式在部分相干干涉测量下的准确性比较

Comparison of 13 formulas for IOL power calculation with measurements from partial coherence interferometry.
PubMed 文献 · Br J Ophthalmol · 2020-06-10

所有公式平均预测误差为零,Barrett Universal II(无前房深度)标准差最低(±0.343 D),Kane中位绝对误差最低(0.214 D);各公式中位绝对误差差异有统计学意义(p<0.0001)。结论认为所有公式结果良好,新型公式有更优趋势,传统公式仍可作为准确选择。

要点

  • 所有13种公式平均预测误差均为零,整体准确性良好。
  • Barrett Universal II(无前房深度)标准差最低(±0.343 D)。
  • Kane中位绝对误差最低(0.214 D),各公式差异显著(p<0.0001)。

核心结论

  • 所有研究的公式均取得良好结果,新型公式有结果更优的趋势,传统公式仍可视为准确选择。

主要发现

  • 所有公式的平均预测误差均为零。
  • Barrett Universal II(无前房深度)标准差最低(±0.343 D),其次为T2(0.347 D)、Kane(0.348 D)、EVO 2.0(无前房深度,0.348 D)和Barrett Universal II(有前房深度,0.353 D)。
  • 各公式中位绝对误差差异有统计学意义(p<0.0001),最低为Kane(0.214 D)、RBF 2.0(0.215 D)、Barrett Universal II(有和无前房深度,0.218 D)及SRK/T(0.223 D)。
  • 预测误差在±0.50 D以内的眼占比范围为80%至88.5%,所有公式预测误差在±0.25 D以内的眼均超过50%。

关键数值与推荐

  • 预测误差在±0.50 D以内的眼占比范围为80%至88.5%。
  • 所有公式预测误差在±0.25 D以内的眼均超过50%。
  • 各公式中位绝对误差差异有统计学意义(p<0.0001)。

临床怎么用

  • 临床可参考各公式的预测误差分布选择IOL度数计算公式,新型公式可能带来更优结果,传统公式仍可作为准确选项。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To compare the accuracy of 13 formulas for intraocular lens (IOL) power calculation in cataract surgery. METHODS: In this retrospective interventional case series, optical biometry measurements were entered into these formulas: Barrett Universal II (BUII) with and without anterior chamber depth (ACD) as a predictor, EVO 2.0 with and without ACD as a predictor, Haigis, Hoffer Q, Holladay 1, Holladay 2AL, Kane, Næser 2, Pearl-DGS, RBF 2.0, SRK/T, T2 and VRF. The mean prediction error (PE), median absolute error (MedAE), mean absolute error and percentage of eyes with a PE within ±0.25, ±0.50, ±0.75 and ±1.00 diopters (D) were calculated. RESULTS: Two hundred consecutive eyes were enrolled. With all formulas, the mean PE was zero. The BUII with no ACD had the lowest standard deviation (±0.343 D), followed by the T2 (0.347 D), Kane (0.348 D), EVO 2.0 with no ACD (0.348 D) and BUII with ACD (0.353 D) formulas. The difference among the MedAEs of all formulas was statistically significant (p<0.0001); the lowest values were achieved with the Kane (0.214 D), RBF 2.0 (0.215 D), BUII with and without ACD (0.218 D) and SRK/T (0.223 D). A percentage ranging from 80% to 88.5% of eyes showed a PE within ±0.50 D and all formulas achieved more than 50% of eyes with a PE within ±0.25 D. CONCLUSION: All investigated formulas achieved good results; there was a tendency towards better outcomes with newer formulas. Traditional formulas can still be considered an accurate option.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Savini G, Di Maita M, Hoffer KJ, et al. Comparison of 13 formulas for IOL power calculation with measurements from partial coherence interferometry. Br J Ophthalmol. 2020. PMID: 32522789. doi:10.1136/bjophthalmol-2020-316193

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。