SS-OCT广角图对近视眼原发性开角型青光眼的诊断准确性
这项前瞻性病例对照研究纳入150只近视POAG眼和100只健康近视眼,同日随机顺序行SD-OCT与SS-OCT检查。SS-OCT广角厚度图在颞下和颞上区域对青光眼性缺损的准确性优于SD-OCT厚度图,GCL++和GCL+平均厚度的AUROC显著高于SD-OCT的GCIPL厚度(87.6%和87.5% vs 83.8%)。
要点
- SS-OCT广角RNFL厚度图对颞下区青光眼性缺损准确性达96.4%,颞上区达92.4%。
- SS-OCT的GCL++和GCL+平均厚度AUROC分别为87.6%和87.5%,显著高于SD-OCT的GCIPL(83.8%)。
- 近视眼中SS-OCT广角图对POAG的诊断效能优于SD-OCT。
核心结论
- 在近视眼中,SS-OCT广角图对青光眼性缺损的准确性及对POAG的诊断效能均优于SD-OCT。
- 该结果可能与SS-OCT更宽的扫描和测量区域有关。
研究设计与样本
- 前瞻性病例对照研究,纳入150只近视POAG眼和100只健康近视眼。
- 所有受试眼在同一天以随机顺序接受SD-OCT和SS-OCT检查。
- 对SD-OCT厚度图和偏差图及SS-OCT广角厚度图和SuperPixel图上青光眼性缺损的位置进行评级并比较准确性。
- 计算并比较各设备视盘周围RNFL及黄斑参数(GCL++、GCL+)用于近视性POAG的AUROC。
主要发现
- SS-OCT广角RNFL厚度图对颞下区青光眼性缺损的准确性为96.4%,对颞上区为92.4%。
- SS-OCT的RNFL/GCL++/GCL+广角厚度图对颞上和颞下区青光眼性缺损的准确性均优于SD-OCT厚度图(所有P值<.05)。
- SS-OCT的GCL++平均厚度AUROC为87.6%,GCL+平均厚度AUROC为87.5%,均显著高于SD-OCT的GCIPL厚度(83.8%,所有P值<.05)。
关键数值与推荐
- SS-OCT广角RNFL厚度图对颞下区青光眼性缺损准确性96.4%。
- SS-OCT广角RNFL厚度图对颞上区青光眼性缺损准确性92.4%。
- SS-OCT GCL++平均厚度AUROC 87.6%,GCL+平均厚度AUROC 87.5%。
- SD-OCT GCIPL厚度AUROC 83.8%。
- SS-OCT厚度图与SD-OCT厚度图准确性比较,所有P值<.05;AUROC比较,所有P值<.05。
临床怎么用
- 在近视眼中评估POAG时,可优先考虑SS-OCT广角图以提高青光眼性缺损的检出准确性。
- SS-OCT的GCL++和GCL+厚度参数对近视性POAG具有较好的诊断效能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the accuracy of glaucomatous defects and diagnostic power for primary open-angle glaucoma (POAG) between swept-source optical coherence tomography (SS-OCT) and spectral-domain OCT (SD-OCT) in myopic eyes. DESIGN: Prospective, case-control study. METHODS: A total of 150 myopic POAG eyes and 100 healthy myopic eyes underwent SD-OCT and SS-OCT in random order on the same day. The locations of glaucomatous defects on SD-OCT thickness and deviation maps and SS-OCT wide-field thickness (thickness surfaces) and SuperPixel maps were rated, and the maps' accuracies were compared. The area under receiver operating characteristic (AUROC) of the peripapillary retinal nerve fiber layer (RNFL) and the macular parameters (GCL++: equivalent to ganglion cell-inner plexiform layer [GCIPL] + RNFL; GCL+: equivalent to GCIPL) from each of the devices for myopic POAG were calculated and compared. RESULTS: The wide-field RNFL thickness (thickness surface) map showed the best accuracy for glaucomatous defects in the inferotemporal (96.4%) and superotemporal (92.4%) regions. The RNFL/GCL++/GCL+ wide-field thickness (thickness surface) map showed better accuracy for glaucomatous defects in both the superotemporal and inferotemporal regions than with the SD-OCT thickness map (all P values <.05). The average GCL++ (87.6%) and GCL+ (87.5%) thicknesses showed significantly greater AUROC for myopic POAG than GCIPL thickness from SD-OCT (83.8%, all P values <.05). CONCLUSIONS: In myopic eyes, the SS-OCT wide-field map exhibited better accuracy for glaucomatous defect and greater diagnostic power for POAG than SD-OCT outcomes. This result might have been due to SS-OCT's wider scan and measurement area.
引用
- Kim YW, Lee J, Kim JS, et al. Diagnostic Accuracy of Wide-Field Map from Swept-Source Optical Coherence Tomography for Primary Open-Angle Glaucoma in Myopic Eyes. Am J Ophthalmol. 2020. PMID: 32574775. doi:10.1016/j.ajo.2020.05.032
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。