ICL V4c植入术后四年角膜内皮细胞密度变化及相关因素观察
这项回顾性连续研究纳入25例近视患者48眼,随访至少4年(平均52±2.9个月),评估ICL V4c植入术后角膜内皮细胞密度(ECD)变化及相关因素。末次随访ECD较术前下降4.03%±2.2%,ECD变化与拱高、角膜内皮至中央ICL距离(C-ICL)、前房角(ACA)变化及前房容积(ACV)变化显著相关,其中拱高是最显著因素。
要点
- ICL V4c植入术后平均随访52±2.9个月,末次随访ECD较术前下降4.03%±2.2%。
- ECD变化与拱高、C-ICL、ACA变化及ACV变化显著相关,拱高为最显著因素。
- 安全指数1.23±0.22、有效性指数1.04±0.16,无眼别CDVA下降,67%眼别视力提升≥1行。
核心结论
- ICL V4c植入术矫正近视安全有效,术后四年角膜内皮细胞密度较术前下降4.03%±2.2%。
- 拱高是影响ECD变化的最显著因素,C-ICL、ACA变化及ACV变化也与ECD变化显著相关。
研究设计与样本
- 回顾性连续研究,纳入25例近视患者共48眼,均行ICL V4c植入术并随访至少4年,平均随访52±2.9个月。
主要发现
- 末次随访时ECD较术前下降4.03%±2.2%。
- ECD变化与拱高、C-ICL、ACA变化及ACV变化显著相关,拱高为最显著因素。
- 随访期间无并发症,安全指数1.23±0.22,有效性指数1.04±0.16。
- 无眼别CDVA下降,67%眼别CDVA提升1行及以上。
- 79%眼别术后屈光度在目标值±0.50 D以内,100%在±1.0 D以内。
临床怎么用
- ICL V4c术后长期随访中应关注角膜内皮细胞密度变化,并结合拱高、C-ICL及前房参数进行评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To evaluate the changes in corneal endothelium cell density (ECD) and the correlated factors after Implantable Collamer Lens (ICL) V4c implantation. METHODS: In this retrospective, consecutive study, 48 eyes of 25 patients with myopia who underwent ICL V4c implantation were enrolled. Patients were followed up for at least 4 years, during which manifest refraction, uncorrected distance visual acuity, corrected distance visual acuity (CDVA), intraocular pressure, ECD, anterior chamber depth, anterior chamber volume (ACV), anterior chamber angle (ACA), vault and distance from the corneal endothelium to the central ICL (C-ICL) were measured. Spearman's correlation analysis was used to identify variables correlated with changes in ECD, and generalised estimating equation model adjusting within-patient intereye correlations was used to predict changes in ECD. RESULTS: All surgeries were performed safely with no complications during follow-up (average 52±2.9 months). Safety and efficacy indices were 1.23±0.22 and 1.04±0.16, respectively. No eyes had decreased CDVA, and 67% gained one or more lines. Further, 79% were within ±0.50 D, and 100% were within ±1.0 D of the attempted refraction. Additionally, a 4.03%±2.2% reduction in ECD compared with the preoperative value was observed at the last follow-up visit. Changes in ECD were significantly correlated with vault, C-ICL, change in ACA and change in ACV. Vault was the most significant factor for changes in ECD. CONCLUSIONS: ICL V4c implantation is safe and effective for myopia correction. Anterior segment biometric parameters including the vault, ACA and C-ICL may influence changes in ECD; specifically, the vault plays a major role.
引用
- Yang W, Zhao J, Sun L, et al. Four-year observation of the changes in corneal endothelium cell density and correlated factors after Implantable Collamer Lens V4c implantation. Br J Ophthalmol. 2020. PMID: 32546550. doi:10.1136/bjophthalmol-2020-316144
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。