OCT诊断青光眼的系统评价再评价

Accuracy of optical coherence tomography for diagnosing glaucoma: an overview of systematic reviews.
PubMed 文献 · Br J Ophthalmol · 2020-06-03

该再评价纳入4篇2015–2018年系统评价,评估OCT诊断青光眼的准确性。两篇低偏倚风险系统评价报告平均RNFL厚度诊断青光眼敏感度0.69和0.78,特异度0.94和0.93。原始研究和二次研究方法学质量均需改进。

要点

  • 两篇可靠系统评价示平均RNFL厚度诊断青光眼敏感度中等、特异度高。
  • 仅一篇系统评价明确描述了临床路径。
  • 原始诊断准确性研究方法学质量有待提高。

核心结论

  • 已发表的OCT诊断青光眼系统评价质量参差不齐。
  • 两篇可靠系统评价发现平均RNFL厚度诊断明确青光眼敏感度中等、特异度高。

研究设计与样本

  • 系统评价再评价,检索Cochrane Eyes and Vision美国维护的眼与视觉系统评价数据库。
  • 两名作者独立筛选记录、提取数据并使用RoBIS清单评估偏倚风险。
  • 纳入4篇2015–2018年发表的系统评价,每篇纳入17至113项OCT诊断青光眼研究。

主要发现

  • 两篇低偏倚风险系统评价报告平均RNFL厚度诊断青光眼敏感度分别为0.69(95%CI 0.63–0.73)和0.78(95%CI 0.74–0.83)。
  • 上述两篇系统评价特异度分别为0.94(95%CI 0.93–0.95)和0.93(95%CI 0.92–0.95),分别基于57项和50项研究。
  • 另两篇系统评价有两至四个领域存在高偏倚风险或不明确偏倚风险,并存在适用性担忧。
  • 仅一篇系统评价明确描述了临床路径。
  • 两篇可靠系统评价均强调原始诊断准确性研究的局限性。

临床怎么用

  • 平均RNFL厚度OCT测量可作为青光眼诊断的辅助依据,但敏感度中等,需结合临床综合判断。
  • 解读OCT诊断准确性证据时应注意原始研究和系统评价的方法学质量。

局限性

  • 纳入的系统评价数量少(仅4篇),且方法学质量参差不齐。
  • 原始诊断准确性研究存在局限性,影响证据可靠性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To assess the diagnostic accuracy (DTA) of optical coherence tomography (OCT) for detecting glaucoma by systematically searching and appraising systematic reviews (SRs) on this issue. METHODS: We searched a database of SRs in eyes and vision maintained by the Cochrane Eyes and Vision United States on the DTA of OCT for detecting glaucoma. Two authors working independently screened the records, abstracted data and assessed the risk of bias using the Risk of Bias in Systematic Reviews checklist. We extracted quantitative DTA estimates as well as qualitative statements on their relevance to practice. RESULTS: We included four SRs published between 2015 and 2018. These SRs included between 17 and 113 studies on OCT for glaucoma diagnosis. Two reviews were at low risk of bias and the other two had two to four domains at high or unclear risk of bias with concerns on applicability. The two reliable SRs reported the accuracy of average retinal nerve fibre layer (RNFL) thickness and found a sensitivity of 0.69 (0.63 to 0.73) and 0.78 (0.74 to 0.83) and a specificity of 0.94 (0.93 to 0.95) and 0.93 (0.92 to 0.95) in 57 and 50 studies, respectively. Only one review included a clear specification of the clinical pathway. Both reviews highlighted the limitations of primary DTA studies on this topic. CONCLUSIONS: The quality of published DTA reviews on OCT for diagnosing glaucoma was mixed. Two reliable SRs found moderate sensitivity at high specificity for average RNFL thickness in diagnosing manifest glaucoma. Our overview suggests that the methodological quality of both primary and secondary DTA research on glaucoma is in need of improvement.